04 Plans 2025-06 Aldrich Street.pdf
PDF 3 MB Posted
- Attached to
- Aldrich Street Improvements
- Solicitation number
- 2025-11
- Issued by
- Washtenaw County, Burt CDP, Michigan
About this file
The document is a comprehensive set of construction plans for the Aldrich Street Improvements project by the City of Cadillac, Michigan. The project involves street reconstruction from Linden Street to Bond Street, spanning approximately 13.6 stations (POB STA 10+40 to POE STA 24+00). Key improvements include HMA paving, concrete curb and gutter, sidewalk ramp improvements for ADA compliance, storm sewer installation, sanitary sewer improvements, and hydrant replacements. The project will reconstruct the street with 12-foot lanes, include various drainage structures, and cross multiple intersections including railroad tracks. The plans are dated June 23, 2025, and prepared by Prein & Newhof engineering firm.
The project includes significant utility work, with detailed specifications for water main and sanitary sewer improvements, adherence to City of Cadillac and Michigan Department of Transportation standards, and careful coordination with existing underground utilities. Approximate quantities include 4,700 square yards of aggregate base, 760 tons of HMA, 1,400 linear feet of curb and gutter, and 1,390 linear feet of sanitary sewer main. The project will require careful traffic management, maintaining access to residences and businesses, and following the 2011 Michigan Manual of Uniform Traffic Control Devices. Contractors must comply with utility protection regulations, including dialing 811 at least three working days before excavation, and all water main and sewer materials must be American-made.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
PLANS FOR
NOTES APPLYING TO STANDARD PLANS
CITY OF CADILLAC
ALDRICH STREET IMPROVEMENTS
ANY SIGNS NECESSARY WITHIN THE PROJECT LIMITS.
CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION SIGNING FOR STREET CLOSURES AND
BUSINESSES SHALL BE MAINTAINED AT ALL TIMES.
THE PROJECT WILL BE CLOSED TO THROUGH TRAFFIC HOWEVER ACCESS TO ALL RESIDENCES AND
2011 EDITION OF THE MICHIGAN MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES.
PLACING OF TEMPORARY TRAFFIC CONTROL ITEMS SHALL BE DONE IN ACCORDANCE WITH THE
OWNERS WHO MAY NOT BE A PART OF THE "MISS DIG" ALERT SYSTEM.
NOTIFIED. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF NOTIFYING UTILITY
WHERE PUBLIC UTILITIES HAVE NOT BEEN PREVIOUSLY LOCATED. MEMBERS WILL THUS BE ROUTINELY
EXCLUDING SATURDAYS, SUNDAYS, AND HOLIDAYS PRIOR TO BEGINNING EACH EXCAVATION IN AREAS
THE CONTRACTOR SHALL DIAL 1-800-482-7171 OR 811 A MINIMUM OF THREE FULL WORKING DAYS, FOR PROTECTION OF UNDERGROUND UTILITIES AND IN CONFORMANCE WITH PUBLIC ACT 174, 2013, CONDITIONS.
CADILLAC SPECIFICATIONS (DATED 2019) AND AS MODIFIED BY ANY MDEGLE PART 399 PERMIT
WATER MAIN IMPROVEMENTS SHALL ONLY BE COMPLETED IN ACCORDANCE WITH THE CITY OF
CONDITIONS.
CADILLAC SPECIFICATIONS (DATED 2019) AND AS MODIFIED BY ANY MDEGLE PART 41 PERMIT
SANITARY SEWER IMPROVEMENTS SHALL ONLY BE COMPLETED IN ACCORDANCE WITH THE CITY OF
STANDARD SPECIFICATIONS AND DETAILS.
AS AMENDED BY SUPPLEMENTAL SPECIFICATIONS, SPECIAL PROVISIONS AND THE CITY OF CADILLAC
MICHIGAN DEPARTMENT OF TRANSPORTATION 2020 STANDARD SPECIFICATIONS FOR CONSTRUCTION
THE IMPROVEMENTS COVERED BY THESE PLANS SHALL BE DONE IN ACCORDANCE WITH THE
- LINDEN STREET TO BOND STREET -
ALDRICH STREET
POB STA 10+40 TO POE STA 24+00
DRIVEWAY OPENINGS & APPROACHES AND CONCRETE SIDEWALKS R-29-J
CONCRETE CURB AND CONCRETE CURB & GUTTER R-30-G
UTILITY TRENCHES R-83-C
BUMPER & PARKING RAILS, AND MISC. WOOD POSTS R-74-D
INDICATED.
ACCORDING TO THE STANDARD PLAN GIVEN BELOW OPPOSITE EACH ITEM UNLESS OTHERWISE
WHERE THE FOLLOWING ITEMS ARE CALLED FOR ON PLANS, THEY ARE TO BE CONSTRUCTED
PLAN SHEET INDEX
DESCRIPTION
TITLE SHEET
LEGEND SHEET
SHT NO.
8 - 16
DRAINAGE STRUCTURES R-1-G
CURB RAMP AND DETECTABLE WARNING DETAILS R-28-K
NOTE SHEET & MISCELLANEOUS QUANTITIES3
PLAN AND PROFILE SHEETS
WATER MAIN DETAILS
TYPICAL CROSS SECTIONS AND SOIL BORINGS
SANITARY SEWER IMPROVEMENTS, AND HYDRANT REPLACEMENTS.
SIDEWALK RAMP IMPROVEMENTS FOR ADA COMPLIANCE, STORM SEWER,
STREET RECONSTRUCTION INCLUDING HMA PAVING, CONCRETE CURB AND GUTTER,
APPROACH DETAILS
TITLE SHEET
COVER K R-15-G
COVER Q R-18-F
COVER B R-7-F
7 SANITARY SEWER DETAILS
PROJECT DESCRIPTION
SOIL EROSION & SEDIMENTATION CONTROL MEASURES R-96-E
LOCAL AGENCY GRADE CROSSING APPROACHES RR-20
17 RAILROAD CROSSING DETAILS
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
BH#
W
Hh
Mh
T
PS
W O R
CP
BM
W
T
T
C
FO
G
T
T
C
SURVEY
BOUNDARY
BORINGS
CURB & GUTTER
SURFACING
VEGETATION
PARCEL - NON-LEGAL
PLAT - NON-LEGAL
SECTION LINE
PARCEL - LEGAL
PLAT - LEGAL
TOWNSHIP LINE (MAP)
CITY LIMIT
BRUSH LINE
HEDGE LINE
TREE LINE - CANOPY OR TRUNK
HMA COLDMILLING
TYPICAL SECTION
CONCRETE - PROPOSED
CURB & GUTTER REMOVAL
WATER
SANITARY SEWER
SEWER
SEWER - OUT OF SERVICE
SEWER - TO BE REMOVED
CONTROL POINT
BENCHMARK
REFERENCE - NGS
REFERENCE - USGS
MONUMENT BOX
DROP INLET
SIDEWALK - CURB RAMP
ABANDON
ADJUST
BULKHEAD
CLEARING
REMOVE
SALVAGE
SAVE
SIDEWALK - CONCRETE RAMP
SIDEWALK
SIDEWALK - LANDING
SIDEWALK - REMOVAL
REFERENCE - GPS
REMOVAL
CONSTRUCTION
GENERAL LABELING
GENERAL
TRAFFIC FLOW ARROW
LEFT TURN ARROW
AGGREGATE APPROACH
BRIDGE APPROACH
HMA APPROACH
MISCELLANEOUS CONCRETE
HMA CRUSH & SHAPE
OR
CONCRETE RUBBLIZING
REMOVAL AND CONSTRUCTION
REMOVAL
PROPOSED
PAVEMENT REMOVAL
AND / OR
HMA SURFACE REMOVAL
FLOW DIRECTION ARROW
DRAINAGE STRUCTURE NUMBER
ALIGNMENT POINT MONUMENT
CITY LIMIT - MAP
DITCH CENTERLINE
GENERAL
CONTROL
CONCRETE MONUMENT
PLAT CORNER
SIDEWALK - DETECT. WARNING SURF.
REMOVE - BY OTHERS
ADJUST - BY OTHERS
NOTE:
PROPOSED ITEMS ARE REPRESENTED BY HEAVIER LINE WEIGHTS.
EXISTING ITEMS ARE REPRESENTED BY THIN LINE WEIGHTS.
PARCEL CORNER - CAPPED IRON
PARCEL CORNER - IRON PIN
PARCEL CORNER - IRON PIPE
PARCEL CORNER - NO ID
ROW MONUMENT
SECTION CORNER - CENTER
SECTION CORNER - MEANDER
SECTION CORNER - QUARTER
SECTION CORNER - QUARTER-HALF
SECTION CORNER - SECTION
SECTION CORNER - SECTION-HALF
SECTION CORNER - SIXTEENTH
SECTION CORNER - WITNESS
ADJUST - STRUC COVER WITH TYPE
RELOCATE - WITH CASE NUMBER
WATER EDGE
UNDERDRAIN
CULVERT - EXISTING
STORM SEWER - EXISTING
STORM SEWER
DRAINAGE
CULVERT (SIZE VARIES)
END SECTION (SIZE VARIES)
OUTLET HEADWALL (SIZE VARIES)
HEADWALL (SIZE VARIES)
CATCH BASIN W/ COVER (DIA VARIES)
MANHOLE W/ COVER (DIA VARIES)
MANHOLE BASE W/ COVER (SIZE VARIES)
MANHOLE TEE W/ COVER (SIZE VARIES)
TREE LINE - TRUNK
TRUNK LINE
MANHOLE WITH COVER (DIA VARIES)
WATER MAIN
WATER MAIN - OUT OF SERVICE
WATER MAIN - TO BE REMOVED
IRRIGATION SPRINKLER HEAD
SERVICE METER
CABLE
POLE UTILITY
TRANSFORMER - POLE MOUNTED
FIRE HYDRANT
DRAIN CASTING
SEWER - TO BE TAKEN OUT OF SERVICE
WATER MAIN - TO BE TAKEN OUT OF SERVICE
TRANSFORMER - PAD MOUNTED
MANHOLE
CABLE OVERHEAD
CONTROLLER CABINET - PAD MOUNTED
TREE - STUMP
TREE - DECIDUOUS
TREE - CONIFER
SHRUB
HANDHOLE
STORM SEWER - TO BE REMOVED
ROW - FREE ACCESS
ROW - LIMITED ACCESS
ELECTRICAL
IRRIGATION CONTROL VALVE
POLE UTILITY - EXISTING
HMA - PROPOSED
GATE VALVE IN WELL
WATER WELL
SERVICE SHUTOFF
GATE VALVE AND BOX
BORING
SECTION LINE - EIGHTH
SECTION LINE - QUARTER
SECTION LINE - SIXTEENTH
IRRIGATION
PROPERTY OWNERSHIP ARROW
CONTIGUOUS PROPERTY SYMBOL
PARCEL NUMBER BOX
ARROW - DOUBLE
PROPERTY OWNERSHIP
123456
A
C
R
SALV
S
ADJ
ADJ-B/O
ADJ-B
REM-B/O
REL-1
CR-R
B
COMMUNICATION
CABLE - OUT OF SERVICE
CABLE
FIBER OPTIC - OUT OF SERVICE
FIBER OPTIC
CABLE - OVERHEAD
TELEPHONE
TELEPHONE - OVERHEAD
TELEPHONE - OUT OF SERVICE
TELEPHONE BOX
TELEPHONE PEDESTAL
FIBER OPTIC MARKER
CABLE MARKER
CABLE PEDESTAL
TELEPHONE MANHOLE
FIBER OPTIC - OVERHEAD
NATURAL GAS
MARKER
VALVE
WELL
GAS LINE - OUT OF SERVICE
GAS LINE
RELOCATE - BY OTHERSREL-B/O
LEGEND SHEET
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
UTILITY OWNERS WHO MAY NOT BE A PART OF THE "MISS DIG" ALERT SYSTEM.
THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF NOTIFYING
NOT BEEN PREVIOUSLY LOCATED. MEMBERS WILL THUS BE ROUTINELY NOTIFIED.
PRIOR TO BEGINNING EACH EXCAVATION IN AREAS WHERE PUBLIC UTILITIES HAVE
OF THREE FULL WORKING DAYS, EXCLUDING SATURDAYS, SUNDAYS, AND HOLIDAYS
ACT 174, 2013, THE CONTRACTOR SHALL DIAL 1-800-482-7171 OR 811 A MINIMUM
FOR PROTECTION OF UNDERGROUND UTILITIES AND IN CONFORMANCE WITH PUBLIC
AND/OR EXISTING SEWERS DURING THE CONSTRUCTION OF THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO EXISTING WATER MAINS
ENGINEER IF CONFLICTS EXIST. PAYMENT IS CONSIDERED INCLUDED IN OTHER ITEMS.
LINES, PIPE SIZES, AND LOCATIONS PRIOR TO CONSTRUCTION AND NOTIFY THE
THE CONTRACTOR MUST FIELD LOCATE ALL EXISTING UTILITIES TO VERIFY FLOW
EXISTING UTILITIES, WATER MAINS, AND SEWERS
SIDEWALK AND SIDEWALK RAMP GRADES
DETAIL GRADES
EARTHWORK & PAVEMENT
UTILITY SEPARATION
PROPOSED DRAINAGE STRUCTURES
ALL PLAN GRADES TO BE VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION. ADJACENT TO CONSTRUCTION ACTIVITIES.
INLET PROTECTION, FABRIC DROPS MUST BE USED AT ALL CATCH BASINS
AS DIRECTED BY THE ENGINEER.
ESTABLISHMENT ITEMS AS SOON AS POSSIBLE ON POTENTIAL ERODIBLE SLOPES
BE IN PLACE PRIOR TO EARTH-DISTURBING ACTIVITIES. PLACE TURF
APPROPRIATE SOIL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL
MADE IN AMERICA
ALL WATER MAIN FITTINGS AND MATERIALS SHALL BE AMERICAN MADE.
LATERALS
UTILITY NOTES
SIGNS
UNDERGROUND UTILITIES
EXISTING SIGN RELOCATION
TOPSOIL STRIPPING
EARTHWORK
SOIL EROSION MEASURES
PAYMENT FOR SAWCUTS SHALL BE INCLUDED IN REMOVAL ITEMS.
AND GUTTER SHALL BE SAWCUT PRIOR TO REMOVAL.
EXISTING CONCRETE PAVEMENT, HMA PAVEMENT, SIDEWALK, AND/OR CURB
SAWCUTTING
SLOPE RESTORATION
TOPSOIL STRIPPING IS INCLUDED IN THE EARTHWORK PAY ITEMS.
STRIP EXISTING TOPSOIL PRIOR TO PLACING EMBANKMENT OR EXCAVATION OF EARTH.
THE PROJECT.
SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST
NEWLY CONSTRUCTED SIDEWALK OR RAMPS THAT DO NOT MEET A.D.A. REQUIREMENTS
A.D.A. REQUIREMENTS PRIOR TO PLACING CONCRETE.
ALL GRADES SHALL BE FIELD VERIFIED, ADJUSTED AS NECESSARY TO MEET
CONSTRUCTION OF THE SIDEWALK AND SIDEWALK RAMPS.
THE SIDEWALK RAMPS, THE ENGINEER WILL VERIFY THE GRADES AND AUTHORIZE THE
STANDARD PLAN R-28 SERIES AND AS SHOWN ON PLANS. PRIOR TO CONSTRUCTING
ALL SIDEWALK AND SIDEWALK RAMP GRADES SHALL BE STAKED ACCORDING TO
AND PAYMENT SHALL INCLUDE ALL NECESSARY FITTINGS.
ALL ACTIVE LATERALS SHALL BE REPLACED WHETHER SHOWN ON THE PLANS OR NOT
ALL EMBANKMENT MATERIAL SHALL MEET REQUIREMENTS FOR GRANULAR MATERIAL CLASS II.
EARTHWORK FOR INTERSECTIONS, DRIVES, AND SIDEWALK ARE INCLUDED IN PLAN QUANTITIES.
UNLESS OTHERWISE KNOWN CHANGES.
EXCAVATION, EARTH, AND EMBANKMENT, CIP, ARE TO BE PAID AT PLAN QUANTITY
CONTRACTOR MUST BE RESTORED BUT WILL NOT BE INCLUDED IN SLOPE RESTORATION QUANTITIES.
GRADING OR TO SIDEWALK WHERE APPLICABLE. ALL OTHER AREAS DISTURBED BY THE
QUANTITIES WILL BE MEASURED FROM A MAXIMUM OF 3 FEET BEYOND THE LIMITS OF
THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS, HOWEVER SLOPE RESTORATION
NO ADDITIONAL COST TO THE PROJECT.
CONTRACTOR TO CORE THE CONCRETE SIDEWALK IF PVC SLEEVES ARE NOT INSTALLED AT
PAYMENT FOR PVC SLEEVES IS INCLUDED IN PROPOSED SIDEWALK ITEMS.
DIRECTED BY THE ENGINEER PRIOR TO SIDEWALK PLACEMENT.
CONTRACTOR TO INSTALL PVC SLEEVES FOR CITY INSTALLATION OF FUTURE SIGNS AS
WHERE SIGNS ARE TO BE PLACED IN CONCRETE SURFACE A PVC SLEEVE SHALL BE INSTALLED.
CONTRACTORS EXPENSE.
REMOVAL AND STORAGE OPERATIONS SHALL BE REPLACED WITH NEW SIGNS AT THE
LOCATIONS DESIGNATED BY THE ENGINEER. SIGNS AND POSTS DAMAGED DURING THE
SHALL BE SALVAGED AND RESET BY THE CONTRACTOR ON NEW POSTS AT
ANY PERMANENT SIGNS REQUIRING RELOCATION DUE TO CONTRACTOR OPERATIONS
ANY DEVIATION FROM THE MINIMUM SEPARATION MUST BE APPROVED BY EGLE.
SEPARATION REQUIREMENTS MUST BE MEASURED FROM OUTSIDE OF PIPE.
SEWER AND WATER MAIN CROSSINGS.
A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION IS REQUIRED BETWEEN
AND WATER MAIN.
A MINIMUM OF 10' OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN SEWER
GRADES FOR INTERSECTIONS AND DRIVEWAYS
DETERMINED BEFORE CONSTRUCTION IS STARTED.
ALL APPROACHES ARE TO BE CONSIDERED AS COMPLETE UNITS AND THEIR GRADES
SUBBASE
PLACING AGGREGATE IS CONSIDERED INCLUDED IN PAYMENT FOR AGGREGATE BASE.
COMPACTION OF EXISTING SUBBASE MATERIAL PRIOR TO
ARE INCLUDED IN THE NOTE SHEET TO BE USED WHERE DIRECTED BY THE ENGINEER.
IS NECESSARY. MISCELLANEOUS QUANTITIES FOR ADDITIONAL EXCAVATION AND SUBBASE
THE ENGINEER WILL INSPECT THE SUBBASE MATERIAL AND DETERMINE IF REPLACEMENT
UTILITY CONTACT INFORMATION
CONSUMERS ENERGY
OFFICE: 231-779-5536
DTE
609 BJORNSON STREET
BIG RAPIDS, MI 49307
ATTN: LARRY BOURKE
OFFICE: 231-592-3244
CELL: 231-349-2364
AT&T
205 E. HARRIS STREET
CADILLAC, MI 49601
ATTN: JEFFREY SHUSTER
OFFICE: 231-779-8451
CELL: 231-510-1381
EMAIL: js9865@att.com
CHARTER COMMUNICATIONS
CITY OF CADILLAC - UTILITIES DEPT.
200 NORTH LAKE STREET
CADILLAC, MI 49601
ATTN: JEFF DIETLIN
OFFICE: 231-775-0181 ext 124
EMAIL: utilities@cadillac-mi.net
ELECTRIC GAS
TELEPHONE CABLE
WATER MAIN & SANITARY SEWER
EMAIL: lawrence.bourke@dteenergy.com
ATTN: ERIC MARR
CADILLAC, MI 49601
CELL: 231-250-4505
EMAIL: eric.marr@cmsenergy.com
EVERSTREAM
OFFICE: 616-608-8945
FIBER
ATTN: BRIAN KUNTER
GRAND RAPIDS, MI 49546
EMAIL: bkunter@everstream.net
3950 SPARKS DR SE
330 CHESTNUT STREET
1392 TRADE CENTRE DRIVE
TRAVERSE CITY, MI 49696
PENINSULA FIBER NETWORK, LLC
OFFICE: 906-353-6644
FIBER
ATTN: JON FRENCH
BARAGA, MI 49908
EMAIL: jfrench@up.net
PO BOX 9 204 STATE STREET
AGGREGATE BASE
BASES
AGGREGATE BASES SHALL USE AGGREGATE 21AA, UNLESS OTHERWISE SPECIFIED.
MISCELLANEOUS QUANTITIES
THESE ITEMS ARE NOT DETAILED OR INCLUDED ON THE PLAN AND PROFILE SHEETS:
THE FOLLOWING ITEMS OF WORK SHALL BE DONE AS THEY APPLY THROUGHOUT THE PROJECT.
LSUM1 Mobilization and Maintaining Traffic, Max. $30,000
Ea5 Post, Mailbox
Cyd50 Maintenance Gravel, LM
Ea Erosion Control, Inlet Protection, Fabric Drop4
Cyd500 Excavation, Earth
Cyd500 Subbase, CIP
REPLACE SUBBASE MATERIAL.
THE FOLLOWING ITEMS OF WORK SHALL BE DONE ONLY AS DIRECTED BY THE ENGINEER TO
OFFICE: 231-941-3836
ATTN: GREGG JOHNSON
EMAIL: gregg.johnson@charter.com
CELL: 231-887-7124
Ft250 Curb and Gutter, Rem
Ft250 Curb and Gutter, Conc, Det F4, Modified
AND/OR CURB IN POOR CONDITION.
REPLACE ADDITIONAL CURB AND GUTTER NOT SHOWN ON PLANS FOR SANITARY SEWER LEADS
THE FOLLOWING ITEMS OF WORK SHALL BE DONE ONLY AS DIRECTED BY THE ENGINEER TO
GREAT LAKES CENTRAL RAILROAD
600 OAKWOOD AVENUE
OWOSSO, MI 48867
ATTN: MICHAEL LIVERMORE
CELL: 989-998-6963
EMAIL: mtlivermore@glcrailroad.com
RAILROAD
PO BOX 550
Dlr5,000 Railroad Protection, Flagging (Allowance - RR invoices required for payment)
NOTE SHEET & MISCELLANEOUS QUANTITIES
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HORZ. (FT)
HOUK
2200337
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
2'
(USE 21AA)
AGGREGATE BASE, 6 INCH
PAID AS EXCAVATION, EARTH
GRADE TO THIS LINE
L
T
2.5%2.5%
*FOR INFORMATION ONLY
ITEM
REMARKS
58-28
58-28
TOP COURSE, AWI = 220 MIN
LEVELING COURSE
HMA APPLICATION ESTIMATE
0.05-0.15 GAL* BOND COAT
IDENT NO. PERFORMANCE GRADE
HMA, 4EL
HMA, 4EL
T
L
RATE LBS PER SYD
2% 2%
AND CROWN POINT
PLAN GRADE
PROPOSED SECTION
EXISTING SECTION
3'± 11'± 3'±11'±
EX HMA (2"±)
(TYP)
EX CURB AND GUTTER
OR AS DIRECTED BY ENGINEER
SAVE / REMOVE WHERE SHOWN ON PLANS
HMA SURFACE, REM
ALIGNMENT
CONST.
ALIGNMENT
CONST.
(TYP)
4'
:11
:1
TYPICAL SECTIONS
EXISTING 28'± BOC
28' BOC
)(4"±
EX AGGREGATE
FOR AS PAVT, REM UPON APPROVAL OF ENGINEER.
REMOVAL OF CONCRETE PATCHES IN STREET WILL BE PAID
NOTE:
12' LANE 12' LANE 2' 6'±
2' FLATTER
1:6 OR
(USE 21AA - TYP UNDER ALL CURB)
AGGREGATE BASE, 6 INCH
(TYP)
EMBANKMENT, CIP
(TYP)
CURB AND GUTTER, CONC, DET F4
10'±
FLATTER
1:6 OR
(TYP)
SLOPE RESTORATION
(TYP)
EX SIDEWALK
SAVE
(TYP)
EX SIDEWALK
SAVE
SEE STND PLAN RR-20 FOR RAILROAD CROSSING SECTION
STA 15+00 TO STA 18+50
POB STA 10+40 TO STA 13+25 RT
TO APPLY: POB STA 10+40 TO STA 12+70 LT
TO APPLY: POB STA 10+40 TO POE STA 24+00
3'± 3'±
EXISTING 28'± BOC
(USE 21AA)
AGGREGATE BASE, 6 INCH
PAID AS EXCAVATION, EARTH
GRADE TO THIS LINE
L
T
2.5%2.5%
AND CROWN POINT
PLAN GRADE
11'± LANE 11'± LANE
(TYP)
EX CURB AND GUTTER
SEE DETAIL FOR REPLACEMENT CURB.
OR AS DIRECTED BY ENGINEER.
SAVE / REMOVE WHERE SHOWN ON PLANS
(TYP)
EX SIDEWALK
SAVE
PROPOSED SECTION
STA 18+50 TO STA 23+36
STA 13+25 RT TO STA 15+00 RT
TO APPLY: STA 12+70 LT TO STA 15+00 LT
ALIGNMENT
CONST.
1 3/4"
2'- 4 3/4"
3'-0"
4"4"
#4 BAR
EPOXY COATED
CONC, DET F4, MODIFIED
CURB AND GUTTER,
/8
(MATCH EXISTING CURB)
(MISC. QUANTITY INCLUDED ON NOTE SHEET)
CONDITION AND/OR FOR SANITARY SEWER LEAD CONNECTIONS.
AND AS DIRECTED BY ENGINEER TO REPLACE CURB IN POOR
TO APPLY: STA 20+14 TO STA 20+44
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
FLARE
4'
MATCH EXISTING DRIVE WIDTH
10' MIN.
FLARE
2'
WHERE GREATER THAN 10'
(USE 21AA)
APPROACH, CL I, 6 INCH
ON
DRIVEWAY, NONREINF CONC, 6 INCH
PAID FOR AS PAVT, REM.
REMOVAL OF EXISTING CONCRETE SURFACE
SAVE
EXISTING CONCRETE SIDEWALK
EXISTING DRIVE WIDTH
RESIDENTIAL DRIVE APPROACH
CONC, DET F4
CURB AND GUTTER,
R E
C O
N S
T R
U C
T T
O S
ID
E
W A
L K
25' (T Y P
R
(TYP)
CONC, DET F4
CURB AND GUTTER,
OR AS SHOWN ON PLANS
MATCH EXISTING WIDTH
O N P
LA
N S
O R A S S
H O
W N
AND EXCAVATION, EARTH
PAID FOR AS HMA SURFACE, REM
AND FOR PROPOSED SECTION
REMOVAL OF EXISTING HMA SURFACE
T
L
(USE 21AA)
AGGREGATE BASE, 6 INCH
ON
L
IM
IT
S
S H
O W
N O
N P
L A
N S
R E
C O
N S
T R
U C
T T
O
STREET INTERSECTION APPROACH
VARIABLE
SLOPE RESTORATION
EMBANKMENT, CIP
CONC, DET F4
CURB AND GUTTER,
PAID FOR AS EXCAVATION, EARTH
GRADE TO THIS LINE.
2'
1:6 O
R FLATTE
R 2%
T
L
(USE 21AA)
AGGREGATE BASE, 6 INCH
1:1
INTERSECTION CURB DETAIL
CASTING TYPE PER PLANS
6" MIN, 15" MAX
ADJUSTING RINGS
FINISH GRADE
DIAMETER PER PLANS
PIPE INVERT AND
AROUND SUMP AND BASE
WASHED 6A AGGREGATE
GEOTEXTILE FABRIC AROUND STONE
4 ROWS @ 1' SPACING
2" PERFORATIONS AT 8" CENTERS
AROUND PERFORATED SUMP
GEOTEXTILE FABRIC WRAPPED
S
U M
P
PLAN R-1 SERIES
SOLID CONCRETE BASE PER MDOT STANDARD
Ø PER PLAN
(4' MIN)
HIGHEST INVERT
STONE TO 1' ABOVE
FABRIC WRAPPED
2'-0"
2'-0"
LEACHING BASIN DETAIL
INCLUDED IN PAYMENT FOR DR STRUCTURE, 48 INCH DIA, LEACHING
NOTE: STRUCTURE, GEOTEXTILE, AGGREGATE 6A, AND CLASS II BACKFILL IS
BACKFILL ABOVE AGGREGATE
GRANULAR MATERIAL, CL II
APPROACH DETAILS
AGGREGATE BASE, 6 INCH
4'
UNDER PROPOSED CURB
DIRECTION
TRAFFIC
CURB OPENING 6' WIDER THAN DRIVE WIDTH
IN 1' (TYP)
DUB CURB
RESTRAINED)
(ALL JOINTS
RESTRAINED)
(ALL JOINTS
FOSTER ADAPTER VALVE TO TEE
VALVE TO TEE
FOSTER ADAPTER
WATER MAIN NOTES:
ALL JOINTS BETWEEN TEE AND HYDRANT SHALL BE RESTRAINED.24.
ALL WATER MAIN MATERIAL AND FITTINGS SHALL BE MANUFACTURED IN THE U.S.A.23.
POSSIBLE FROM THE MANHOLE.
MAIN PIPE SHALL BE CENTERED ON THE MANHOLE SUCH THAT THE WATER MAIN JOINTS ARE AS FAR AS
WHERE WATER MAIN INSTALLATION FALLS WITHIN 10' OF STORM OR SANITARY MANHOLES, THE WATER 22.
APPLY TO HYDRANTS LEADS, SERVICES, AND LATERALS AS WELL.
FROM ANY STORM OR SANITARY SEWERS, MEASURED PIPE WALL TO PIPE WALL. THESE REQUIREMENTS
WATER MAINS SHALL HAVE A MINIMUM OF 10' HORIZONTAL CLEARANCE AND 18" VERTICAL CLEARANCE 21.
OTHER FITTINGS SHALL BE RESTRAINED PER CITY OF CADILLAC SPECIFICATIONS.
WHEN VALVES AND FITTINGS ARE INSTALLED TOGETHER, FOSTER ADAPTERS SHALL BE USED. ALL 20.
GATE VALVES SHALL CONFORM THE CITY OF CADILLAC SPECIFICATIONS.19.
HYDRANT BODY.
GLAMORTEX 501 ENAMEL OR APPROVED EQUAL; HYDRANT CAPS SHALL BE PAINTED THE SAME AS
ALL HYDRANTS SHALL BE PAINTED YELLOW ABOVE THE FLANGE AND RED BELOW, WITH A FINISH COAT OF 18.
HYDRANTS SHALL CONFORM TO THE CITY OF CADILLAC SPECIFICATIONS.17.
RESTRAINED PER SPECIFICATIONS.
ALL MAINS ABANDONED SHALL BE CUT AND PLUGGED TWO FEET FROM ACTIVE MAIN OR VALVE AND 16.
REMAIN THE PROPERTY OF THE CITY OF CADILLAC.
ON WATER MAINS THAT ARE ABANDONED, VALVES NO LONGER NEEDED SHALL BE REMOVED AND SHALL 15.
WATER MAIN SHALL BE INCLUDED IN PROPOSED WATER MAIN CONSTRUCTION.
REMOVAL OF ABANDONED WATER MAIN AS REQUIRED FOR CLEARANCE TO CONSTRUCT PROPOSED 14.
EXISTING UTILITIES IS INCLUDED IN THE COST OF WATER MAIN.
WHEN PROPOSED WATER MAIN PASSES BENEATH EXISTING UTILITIES, TEMPORARY SUPPORT OF 13.
INCLUDED IN PAYMENT FOR THE WATER MAIN AND SHALL NOT BE PAID FOR SEPARATELY.
VERIFIED PRIOR TO WATER MAIN CONSTRUCTION. FITTINGS REQUIRED TO AVOID CONFLICT ARE
LOCATIONS AND ELEVATIONS OF POTENTIAL STORM AND SANITARY SEWER CONFLICTS SHALL BE FIELD 12.
PAYMENT SHALL BE INCLUDED IN THE WATER MAIN PAY ITEM.
IF TRENCH BOXES OR OTHER SHORING METHODS ARE NEEDED FOR WATER MAIN CONSTRUCTION, 11.
TERMINATE AT THE FACE OF THE PIPE BELLS.
THRUST BLOCKS SHALL BE POUR AGAINST UNDISTURBED EARTH. ALL THRUST BLOCKS SHALL 10.
THIS OPERATION SHALL BE INCLUDED IN THE WATER MAIN CONSTRUCTION.
DISINFECTED. THIS SHALL INCLUDE ALL PIPE USED FOR CLOSURES AND CONNECTIONS. PAYMENT FOR
ALL PIPE NOT DISINFECTED AS PART OF THE NORMAL DISINFECTING PROCEDURES SHALL BE HAND 9.
WHILE MAKING CONNECTIONS TO EXISTING WATER MAINS SHALL BE AT THE CONTRACTOR'S EXPENSE.
WHILE MAKING CONNECTIONS. ANY ADDITIONAL WATER MAIN REQUIRED TO REPAIR DAMAGE MADE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE DONE TO THE EXISTING WATER MAIN 8.
TO ORDERING FITTINGS.
ITEM. CONTRACTOR SHALL VERIFY SIZE, MATERIAL, AND CONDITION OF EXISTING WATER MAINS PRIOR
VERIFIED PRIOR TO CONSTRUCTION AND SHALL BE INCLUDED IN THE COST OF THE WATER MAIN PAY
FITTINGS REQUIRED TO CONNECT PROPOSED WATER MAIN TO EXISTING WATER MAIN SHALL BE FIELD 7.
DISINFECTED PER SPECIFICATIONS PRIOR TO BEING INTEGRATED INTO THE SYSTEM.
ALL WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 6.0' OF COVER. NEW WATER MAIN SHALL BE 6.
PROPOSED WATER MAIN SHALL BE DUCTILE IRON PIPE, CLASS 52 UNLESS OTHERWISE NOTED.5.
LATEST INFORMATION REGARDING THE LOCATION OF THEIR UTILITIES.
WATER MAIN CONSTRUCTION SHOWN ON THE PLANS. THESE UTILITES SHOULD BE CONSULTED FOR THE
OTHER UTILITIES MAY BE MAKING ALTERATIONS TO THEIR EXISTING SYSTEMS IN THE VICINITY OF THE 4.
UNLESS OTHERWISE SHOWN.
ELEVATIONS OF PROPOSED WATER MAINS SHOWN ON THE PROFILES ARE BOTTOM OF PIPE ELEVATIONS 3.
MAINS.
WATER MAINS ARE SUBJECT TO CHANGE TO SUIT THE ACTUAL ELEVATIONS OF THE EXISTING WATER
PROFILES ARE SHOWN BASED ON AN AVERAGE DEPTH OF COVER OF 6.0'. GRADES OF THE PROPOSED
WHERE DEPTH OF COVER ELEVATIONS FOR EXISTING WATER MAINS WERE NOT AVAILABLE, EXISTING 2.
DETERMINE THE ACTUAL LOCATIONS AND ELEVATIONS.
SHOWN. IT IS ANTICIPATED THAT THE CONTRACTOR MAY HAVE TO EXPOSE THE WATER MAINS TO
MAINS DATA AND NO GUARANTEE IS MADE FOR EITHER THE COMPLETENESS OR ACCURACY OF THOSE
THE LOCATION AND ELEVATION OF EXISTING WATER MAINS ARE SHOWN IN ACCORDANCE WITH AVAILABLE 1.
WATER MAIN DETAILS
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
SANITARY SEWER DETAILS
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
STA 10+59, 9.5' LT
ELEV: 1294.82
NAIL/CAP IN POWER POLE
BM#1
CP#1
1/2" IRON W/ P&N CONTROL CAP
E=19410024.15
N=343591.30
ELEV: 1293.64
STA 11+10, 23.5' LT
BM#1
CP#1
10 11 12 13 141010
.0
S T
A R
T
N
REMOVAL SHEET
POB STA 10+40 TO STA 14+00
Cyd
Syd HMA Surface, Rem
Ft Curb and Gutter, Rem
REMOVAL QUANTITIES THIS SHEET
Excavation, Earth250
DRIVEWAY APPROACHES.
QUANTITIES INCLUDE REMOVALS FOR
Syd Pavt, Rem83
Ea San Structure, Rem2
Ft San Sewer, Rem, Less than 24 inch363
Ea Hydrant, Rem1
LINDEN STREET
LINDEN STREET
A L
D R
IC
H
S T
R E
E T
R
EX. 12" SAN
EX. 6" W.M.
R
EX. 12" SAN
EX. 6" W.M.
R
FOR NEW MANHOLE
NORTH & SOUTH
AND 10' OF 12" SAN
SAN MH
R
HYDRANT
PI= 10+00.00 N=343569.20 E=119409914.39
ALIGNMENT DATA
ALDRICH STREET CENTERLINE
R
GUTTER
CURB AND
E X
W
.M
E X
W .M
E X
S A
N E
X
S A
N
E X
W .M
E X
W
.M
E X
S T
M E
X
S
T M
R
SAN MH
Syd Sidewalk, Rem48
POB STA 10+40
E D
G E
O F
S
ID
E W
A L
K
REMOVE CURB AND GUTTER SAVE CURB AND GUTTER
S T
A
REMOVE CURB AND GUTTER SAVE CURB AND GUTTER
S T
A
R
YIELD SIGN
R
(PEDEST.)
SIGN
R
(RAILROAD)
SIGN
Ea Sign, Type III, Rem3
S
& ROUND POST
STREET SIGNS
E X
S T
M
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
STA 10+59, 9.5' LT
ELEV: 1294.82
NAIL/CAP IN POWER POLE
BM#1
CP#1
1/2" IRON W/ P&N CONTROL CAP
E=19410024.15
N=343591.30
ELEV: 1293.64
STA 11+10, 23.5' LT
BM#1
CP#1
10 11 12 13 141010
.0
S T
A R
T
N
POB STA 10+40 TO STA 14+00
CONSTRUCTION SHEET
Ton
Syd Aggregate Base, 6 inch
CONSTRUCTION QUANTITIES THIS SHEET
HMA, 4EL
Cyd Embankment, CIP60
Ft Curb and Gutter, Conc, Det F4576
Syd Slope Restoration600
Ea Gate Box, Adj, Special1
San Sewer, SDR 26, 12 inch Tr Det B363 Ft
San Sewer, Dr Structure, 48 inch dia2 Ea
Dr Structure Cover, Type Q - EJ SELFLEVEL2 Ea
Syd
DRIVEWAY QUANTITIES THIS SHEET
Driveway, Nonreinf Conc, 6 inch99
Syd Approach, Cl I, 6 inch99
UTILITY QUANTITIES THIS SHEET
Sanitary Sewer, Serv Lead, PVC, 6 inch120 Ft
LINDEN STREET
LINDEN STREET
A L
D R
IC
H
S T
R E
E T
EX. 6" W.M.
PROP 12" SAN
STA 13+60, AT �
SAN STRUCTURE
PROP 4' Ø
SAN 2
EX. 6" W.M.
PROP 12" SAN
' LTSTA 10+57, 1
SAN STRUCTURE
PROP 4' Ø
SAN 1
ADJ
WM VALVE
ASSEMBLY
PROPOSED HYDRANT
STA 11+36, 20' RT
'25
R
R
PI= 10+00.00 N=343569.20 E=119409914.39
ALIGNMENT DATA
ALDRICH STREET CENTERLINE
E X
W .M
E X
W .M
E X
. 1 2"
S A
N E
X . 1
2" S
A N
E X
W .M
E X
W .M
E X
. 1 2"
S T
M E
X . 1
2" S
T M
PROP 12" STM
P R
O P
ADJ-K
ADJ-K
Ea Fire Hydrant Assembly 1
San Sewer, Fernco Coupling , 12 inch (Strong Back RC 5000 Series)2 Ea
Ft Sewer, Cl E, 12 inch, Tr Det B214
Ea Dr Structure, 24 inch dia1
Dr Structure Cover, Type K5 Ea Dr Structure Cover, Adj, Case 1Ea2
Ea Dr Structure, 48 inch dia2
POB STA 10+40
E D
G E
O F
S
ID
E W
A L
K
(TYP ALL RAMPS)
DETECTABLE WARNING PLATES
6' RAMP OPENING &
NOTE:
Sft Curb Ramp, Conc, 6 inch432 Ft Detectable Warning Surface, Cast Iron18
STM 3
STA 12+60, 13' LT
STM STRUCTURE
PROP 2' Ø
STM 2
STA 12+60, 14' RT
STM STRUCTURE
PROP 4' Ø
Sft Sign, Type IIIA7
TAP 12" STM
STM 1
STA 11+06, 14' RT
STM STRUCTURE
PROP 4' Ø
E X
. 1 2"
S T
M
Ea Dr Structure, Tap, 12 inch1
(SAVE STREET SIGNS)
ON EXISTING ROUND POST
6.25 SFT SIGN, TYPE IIIA
R1-1 (30")
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
.9
.8
.6
.8
.1
.6
.1
.6
.1
+3.56 %-1.14%
+0.70%
+0.96%
.0
.5
.8
.2
.5
.9
.4
.9
.9
.8
.6
.8
.1
.6
.1
.6
.1
+3.56 %-1.14%
+0.70%
+0.96%
.0
.5
.8
.2
.5
.9
.4
.9
POB STA 10+40 TO STA 14+00
PROFILE SHEET
POB STA 10+40
E D
G E
O F
S
ID
E W
A L
K
LINDEN STREET
LINDEN STREET
E
D G
E O
F S
ID
E
W A
L K
POB STA 10+40
EX. SAN MH
R
1286.85 12" E
1286.90 12" W INV:
1295.56RIM:
4' DIA SAN MH - COVER Q
�STA 13+60, AT
SAN 1
EX. SAN MH
R
1287.78 12" E
1287.81 12" S
1287.89 12" N INV:
1293.11RIM:
4' DIA SAN MH - COVER Q
STA 10+57, 1' LT
SAN 2
EX. 12" SAN (CLAY)
R
PROP 12" SAN @ 0.29%
PROP 12" SAN @ 0.26%
(CLAY)
EX. 12" SAN
R
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
SANITARY SEWER PROFILE
STORM SEWER PROFILE
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
PROP 12" STM @ 0.48%
STM 2
1290.60 12" W
1290.60 12" NINV:
1294.20RIM:
4' DIA STM CB - COVER K
STA 12+60, 14' RT
STM 3
1290.70 12" SINV:
1294.20RIM:
' DIA STM CB - COVER K2
STA 12+60, 13' LT
STM 2
1289.90 12" SW
1289.90 12" EINV:
1293.20RIM:
4' DIA STM CB - COVER K
STA 11+06, 14' RT
1289.80 12" NE - TAP
1289.77 12" S
1289.67 12" NINV:
1293.07RIM:
EX 4' DIA STM CB - COVER K
ADJ-K
PROP 12"
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
10 11 12 13 14
10 11 12 13 14
BM#2
STA 17+23, 23.7' LT
ELEV: 1298.06
NAIL/CAP IN POWER POLE
BM#2
CP#2
1/2" IRON W/ P&N CONTROL CAP
E=19410504.74
N=343540.46
ELEV: 1296.86
STA 15+91, 21.7' RT
CP#2
14 15 16 17 18 1915
N
REMOVAL SHEET
STA 14+00 TO STA 19+00
A L
D R
IC
H
S T
R E
E T
A L
D R
IC
H
S T
R E
E T
G.L.C. RAILROAD
G.L.C. RAILROAD
R
SAN MH
R
SAN MH
Cyd
Syd HMA Surface, Rem
Ft Curb and Gutter, Rem
REMOVAL QUANTITIES THIS SHEET
Excavation, Earth300
DRIVEWAY APPROACHES.
QUANTITIES INCLUDE REMOVALS FOR
Syd Pavt, Rem135
Ea San Structure, Rem2
Cyd Flowable Fill, Non-Structural2
R
EX. 12" SAN
R
EX. 12" SAN
EX. 6" W.M.
EX. 6" W.M.
(T Y
P
SAVE CURB AND GUTTER REMOVE CURB AND GUTTER
S T
A
REMOVE CURB AND GUTTER SAVE CURB AND GUTTER
S T
A
SAVE CURB AND GUTTER REMOVE CURB AND GUTTER
S T
A
REMOVE CURB AND GUTTER SAVE CURB AND GUTTER
S T
A
R
(NO PARKING)
SIGN
R
(NO PARKING)
SIGN
R
(PEDEST.)
SIGN
Ea Sign, Type III, Rem3
Syd Sidewalk, Rem14
SIDEWALK CROSSING
50' - REMOVE
THROUGH RAILROAD CROSSING
REMOVE HMA PAVEMENT
THROUGH RAILROAD CROSSING
REMOVE HMA SIDEWALK
MP: 0.00 SOUTH END OF WYE
NI: 000623J
ALDRICH ST
THE RAILROAD TRACK.
FOR A MINIMUM 20' EACH SIDE OF THE CENTERLINE OF
PLACE FLOWABLE FILL IN ABANDONED SANITARY SEWER
Ft San Sewer, Rem, Less than 24 inch460
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
BM#2
STA 17+23, 23.7' LT
ELEV: 1298.06
NAIL/CAP IN POWER POLE
BM#2
CP#2
1/2" IRON W/ P&N CONTROL CAP
E=19410504.74
N=343540.46
ELEV: 1296.86
STA 15+91, 21.7' RT
CP#2
14 15 16 17 18 1915
N
STA 14+00 TO STA 19+00
CONSTRUCTION SHEET
A L
D R
IC
H
S T
R E
E T
A L
D R
IC
H
S T
R E
E T
G.L.C. RAILROAD
G.L.C. RAILROAD
EX. 6" W.M.
EX. 6" W.M.
PROP 12" SAN
PROP 12" STM
PROP 12" SAN
�STA 16+35, AT
SAN STRUCTURE
PROP 4' Ø
SAN 3
Ton Syd Aggregate Base, 6 inch
CONSTRUCTION QUANTITIES THIS SHEET
HMA, 4EL
Cyd Embankment, CIP70
Ft Curb and Gutter, Conc, Det F4622
Syd Slope Restoration700
San Sewer, SDR 26, 12 inch Tr Det B500 Ft San Sewer, Dr Structure, 48 inch dia2 Ea Dr Structure Cover, Type Q - EJ SELFLEVEL2 Ea
Syd
DRIVEWAY QUANTITIES THIS SHEET
Driveway, Nonreinf Conc, 6 inch127 Syd Approach, Cl I, 6 inch127
UTILITY QUANTITIES THIS SHEET
Sanitary Sewer, Serv Lead, PVC, 6 inch320 Ft
40'±
DUB CURB IN 5' LENGTH
15' FROM RAILS (LT & RT)
GAP CURB AND GUTTER
BORE PIT
25' TO
BORE PIT
25' TO
C E
N T
E R
L
IN
E O
F T
R A
C K
S T
A
FOR SANITARY SEWER
60' BORE & JACK STEEL CASING PIPE
Steel Casing Pipe, 24 inch, Jacked in Place, Modified60 Ft Sft Sign, Type IIIA15
Ft Post, Steel, 3 pound75
HMA
20'
Ton Hand Patching20
Sft Curb Ramp, Conc, 6 inch162 Ft Detectable Warning Surface, Cast Iron12
Ea Pavt Mrkg, Polyurea, Railroad Sym2 Ft Pavt Mrkg, Polyurea, 24 inch, Stop Bar72
Sft Sign, Type IIIB13
PLACE RR SYM PAVT MRKG
15 FT 1-POST, STEEL, 3 POUND
6.25 SFT SIGN, TYPE IIIB
W10-1 (30")
FOR RAILROAD CROSSING
SEE STND PLAN R-28
(HAND PATCHING)
CROSSING
THROUGH RAILROAD
PLACE HMA SIDEWALK
DETAILS
FOR DETAILS.
SEE STND PLAN RR-20
CROSSING.
THROUGH RAILROAD
PLACE HMA PAVEMENT
65°
MP: 0.00 SOUTH END OF WYE
NI: 000623J
ALDRICH ST
MIN.
20'
MIN.
20'
(TYP)
APPROX 12' X 24' X 12' DEEP
BORE PIT (20' MIN. FROM TRACKS)
3' BEYOND TOE OF SLOPE; 3' BEYOND THE DITCH; OR A MINIMUM DISTANCE OF 25' FROM THE NEAR RAIL WHEN CASING IS BELOW GROUND.
D. LENGTH OF STEEL CASING PIPE SHALL BE THE DISTANCE AS MEASURED AT RIGHT ANGLES TO THE TRACK:
C. MINIMUM WALL THICKNESS OF 0.407" (13/32") FOR 24" STEEL CASING.
B. MINIMUM YIELD STRENGTH OF 35,000 PSI.
A. EITHER: ASTM A53-TYPE E OR S, GRADE B; OR ASTM A 139-GRADE B
4. STEEL PIPE REQUIREMENTS:
SHALL BE CLOSELY MONITORED FOR SETTLEMENT OR DISPLACEMENT.
WATER IS PRESENT OR ANTICIPATED, FLOW SHALL BE MAINTAINED AT THE SITE. WHEN DEWATERING, THE RAILROAD EMBANKMENT, TRACKS, AND FACILITIES SUPPORTING THE TRACK STRUCTURE, BALLAST SECTION, OR ANY OTHER RAILROAD STRUCTURES (CULVERTS, SIGNALS, SWITCH STANDS, ETC). WHEN
D.SHEETING, SHORING, AND/OR DEWATERING SHALL BE USED TO PREVENT CAVING, SLIDES, OR UNDERMINING OF THE FOUNDATION MATERIAL
MUST BE SUFFICIENT DISTANCE BELOW THE PIPE TO ALLOW A QUALITY WELD.
OVERLAPPING BEADS OF WELD SHALL BE APPLIED AT SEAMS OR JOINTS. DURING FIELD WELDING, WATER SHALL NOT BE PRESENT INSIDE THE PIPE AND
C. WHERE FIELD WELDING IS REQUIRED, THE STEEL PIPE ENDS SHALL BE PREPARED AND A MINIMUM OF 3 COMPLETE CIRCUMFERENCE PASSES, OR 3
FLUSH WITH THE FRONT SLOPE, AND FILLED COMPLETELY WITH GROUT BEFORE AND FURTHER BORE ATTEMPTS ARE MADE.
ENCOUNTERED THAT STOPS THE FORWARD ADVANCEMENT OF THE PIPE, OPERATIONS SHALL CEASE AND THE PIPE SHALL BE ABANDONED IN PLACE, CUT VOIDS. THE AUGER SHALL BE REMOVABLE FROM WITHIN THE PIPE IN THE EVENT AS OBSTRUCTION IS ENCOUNTERED. WHEN AN OBSTRUCTION IS COATING. IF VOIDS SHOULD DEVELOP CREATING A HOLE DIAMETER GREATER THAN 1" PLUS THE PIPE DIAMETER GROUT SHALL BE USED TO FILL SUCH
B. A BORE/JACK INSTALLATION SHALL HAVE A PUSH HOLE ESSENTIALLY THE SAME AS THE OUTSIDE DIAMETER OF THE PIPE PLUS PROTECTIVE
AUGER AND CASING ADVANCEMENT IS COORDINATED. WHERE THE AUGER IS ADVANCED SEPARATELY, THE AUGER SHALL NOT PRECEDE THE CASING PIPE.
WITHIN THE PIPE TO REMOVE THE SPOIL, THE AUGER SHALL NOT BE ADVANCED MORE THAN ONE-HALF THE DIAMETER OF THE CASING PIPE, WHERE THE
A. WHERE THE METHOD OF INSTALLATION CONSISTS OF PUSHING THE CASING PIPE INTO THE SUB GRADE SECTION WITH A BORING AUGER ROTATING
3. JACK AND BORE REQUIREMENTS FOR UNDER RAILROAD:
AS SHOWN ON THE PLANS.
2. NO WORK OR STORING OF EQUIPMENT/MATERIALS SHALL BE ALLOWED WITHIN 20' OF THE CENTERLINE OF THE NEAREST TRACK EXCEPT FOR THE WORK
SECTIONS WILL BE DETERMINED BY THE RAILROAD OR MDOT ENGINEER.
TO REMOVE AND REPLACE THE FOULED BALLAST SECTION, WITH COSTS INVOICED TO THE PERMIT APPLICANT/FACILITY OWNER. FOULING OF BALLAST AND REPLACEMENT WORK AT THE TRACK AREA. ANY MATERIAL FINES THAT ARE PLACED IN THE RAILROAD BALLAST SECTION WILL REQUIRE THE RAILROAD
1. NO CONSTRUCTION EQUIPMENT WILL BE ALLOWED ON THE RAILROAD ROADBED/BALLAST, UNLESS IT IS HI-RAIL EQUIPPED OR FOR PAVEMENT REMOVAL
RAILROAD RIGHT OF WAY CONSTRUCTION NOTES:
RR
15 FT 1-POST, STEEL, 3 POUND
5 SFT SIGN, TYPE IIIA
R8-3a (24" X 30")NO
PARKING
15 FT 1-POST, STEEL, 3 POUND
5 SFT SIGN, TYPE IIIA
R8-3a (24" X 30")
15 FT 1-POST, STEEL, 3 POUND
5 SFT SIGN, TYPE IIIA
R8-20 (24" X 30")
RR
THIS
STREET
PARKING
OFSIDE
NO
NO
PARKING
Bypass Pumping, Sanitary Sewer1 LSUM
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
.1
.4
.5
.8
.0
.3
.9
.6
.4
.4
.1
+0.67%
+0.62% -0.52%
-0.71%
.9
.2
.5
.8
.1
.4
.3
.0
.6
.3
.1
.1
.4
.5
.8
.0
.3
.9
.6
.4
.4
.1
+0.67%
+0.62% -0.52%
-0.71%
.9
.2
.5
.8
.1
.4
.3
.0
.6
.3
.1
STA 14+00 TO STA 19+00
PROFILE SHEET
G.L.C. RAILROAD
G.L.C. RAILROAD
EX. 12" SAN (CLAY)
R
EX. 12" SAN (CLAY)
R
EX. 12" SAN (CLAY)
R
EX. SAN MH
R
EX. SAN MH
R
PROP 12" SAN @ 0.26%
PROP 12" SAN @ 0.26%
1286.10 12" E
1286.15 12" W INV:
1297.40RIM:
4' DIA SAN MH - COVER Q
�STA 16+35, AT
SAN 3
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
SANITARY SEWER PROFILE
STORM SEWER PROFILE
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
60' - 24" CASING PIPE
JACK AND BORE
INV. 1285.60
STA 16+39
INV. 1285.45
STA 16+99
C E
N T
E R
L
IN
E O
F T
R A
C K
S T
A
C E
N T
E R
L
IN
E O
F T
R A
C K
S T
A
THE RAILROAD TRACK.
FOR A MINIMUM 20' EACH SIDE OF THE CENTERLINE OF
PLACE FLOWABLE FILL IN ABANDONED SANITARY SEWER
:1 1
:1
S T
A
E D
G E
O F
B O
R E
P
IT
S T
A
E D
G E
O F
B O
R E
P
IT
25'25'
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 8
VERT. (FT)
HORZ. (FT)
HOUK
2200337
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
14 15 16 17 18 19
14 15 16 17 18 19
CP#3
CP#4
BM#3
STA 23+65, 24.6' LT
ELEV: 1295.83
NAIL/CAP IN POWER POLE
BM#3
CP#3
1/2" IRON W/ P&N CONTROL CAP
E=19410879.19
N=343537.16
ELEV: 1295.71
STA 19+65, 20.6' RT
CP#4
1/2" IRON W/ P&N CONTROL CAP
E=19411265.44
N=343589.40
ELEV: 1295.20
STA 23+51, 36.2' LT
19 20 21 22 23 242020
.5
E
D
N
REMOVAL SHEET
STA 19+00 TO POE STA 24+00
A L
D R
IC
H
S T
R E
E T
GREEN STREET BOND STREET
BOND STREET
R
EX. 12" SAN
EX. 6" W.M.
R
HYDRANT
R
R
EX. 12" SAN
EX. 6" W.M.
E X
S
A N
E X
W
.M
8" SAN SOUTH
AND 40' OF
SAN MH
PI= 24+35.55 N=343552.24 E=119411349.84
ALIGNMENT DATA
ALDRICH STREET CENTERLINE
Cyd
Syd HMA Surface, Rem
Ft Curb and Gutter, Rem
REMOVAL QUANTITIES THIS SHEET
Excavation, Earth300
INTERSECTION APPROACHES.
QUANTITIES INCLUDE REMOVALS FOR
Ea San Structure, Rem1
Ft San Sewer, Rem, Less than 24 inch527
Ea Sign, Type III, Rem2
Syd Sidewalk, Rem77
E X
S A
N
E X
S A
N
E X
W
.M
E X
W
.M
E X
S T
M E
X
S T
M
EX.
" S
TM
E X . 1
" S
T M
POE STA 24+00
E D
G E
O F
C U
R B
(RAILROAD)
SIGN
Ea Hydrant, Rem1
R
SAVE CURB AND GUTTER REMOVE CURB AND GUTTER SAVE CURB AND GUTTER
S T
A
S T
A
SAVE CURB AND GUTTER
CURB AND GUTTER
REMOVE
S T
A
SAVE CURB AND GUTTER
CURB AND GUTTER
REMOVE
S T
A
R
YIELD SIGN
& ROUND POST
STREET SIGNS
S
30'
DR STRUCT.
FOR RAMP AND
REMOVE CURB
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
CP#3
CP#4
BM#3
STA 23+65, 24.6' LT
ELEV: 1295.83
NAIL/CAP IN POWER POLE
BM#3
CP#3
1/2" IRON W/ P&N CONTROL CAP
E=19410879.19
N=343537.16
ELEV: 1295.71
STA 19+65, 20.6' RT
CP#4
1/2" IRON W/ P&N CONTROL CAP
E=19411265.44
N=343589.40
ELEV: 1295.20
STA 23+51, 36.2' LT
19 20 21 22 23 242020
.5
E
D
N
STA 19+00 TO POE STA 24+00
CONSTRUCTION SHEET
A L
D R
IC
H
S T
R E
E T
GREEN STREET BOND STREET
BOND STREET
EX. 6" W.M.
EX. 6" W.M.
E X
S
A N
E X
W
.M
ADJ
WM VALVE
R
R
ASSEMBLY
PROPOSED HYDRANT
STA 19+55, 20' RT
ASSEMBLY
PROPOSED HYDRANT
STA 23+36, 20' RT
PI= 24+35.55 N=343552.24 E=119411349.84
ALIGNMENT DATA
ALDRICH STREET CENTERLINE
E X
S A
N
E X
S A
N
E X
W
.M
E X
W
.M
E X
S T
M E
X
S T
M
PROP 12" SAN
P R
O P S T
M PROP 12" SAN
R
27'
R
�STA 19+90, AT
SAN STRUCTURE
PROP 4' Ø
SAN 4
ADJ
(3 EA)
WM VALVES
ADJ-K
ADJ-K
Ton Syd Aggregate Base, 6 inch
CONSTRUCTION QUANTITIES THIS SHEET
HMA, 4EL
Cyd Embankment, CIP40
Ft Curb and Gutter, Conc, Det F4232
Syd Slope Restoration300
Ea Gate Box, Adj, Special4
San Sewer, SDR 26, 12 inch Tr Det B487 Ft
San Sewer, Dr Structure, 48 inch dia1 Ea Dr Structure Cover, Type Q - EJ SELFLEVEL3 Ea
UTILITY QUANTITIES THIS SHEET
Sanitary Sewer, Serv Lead, PVC, 6 inch120 Ft
Ea Fire Hydrant Assembly 2
San Sewer, Fernco Coupling , 8 inch (Strong Back RC 5000 Series)1 Ea Ft Sewer, Cl E, 18 inch Tr Det B48
Dr Structure Cover, Type K4 Ea Ea Dr Structure, 48 inch dia, Leaching2
San Sewer, SDR 26, 8 inch Tr Det B40 Ft
San Sewer, Fernco Coupling , 12 inch (Strong Back RC 5000 Series)1 Ea
ADJ-B
Dr Structure Cover, Adj, Case 1 Ea5
POE STA 24+00
E D
G E
O F
C U
R B
P R
O P
(TYP ALL RAMPS)
DETECTABLE WARNING PLATES
6' RAMP OPENING &
NOTE:
Sft Curb Ramp, Conc, 6 inch818 Ft Detectable Warning Surface, Cast Iron30 Sft Sign, Type IIIA7
ADJ-Q
STM 5
STA 20+35, 14' LT
(LEACHING)
STM STRUCTURE
PROP 4' Ø
STM 4
STA 20+07, 25.5' RT
(LEACHING)
STM STRUCTURE
PROP 4' Ø
Ft Curb and Gutter, Conc, Det F4, Modified30
Dr Structure Cover, Type B - EJ SELFLEVEL1 Ea
(SAVE STREET SIGNS)
ON EXISTING ROUND POST
6.25 SFT SIGN, TYPE IIIA
R1-1 (30")
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 40
HORZ. (FT)
HOUK
2200337
.1
.1
.1
.7
.5
.2
.2
.1
.8
.6
.1
-0.35%
+0.58% -4.06%
.1
.9
.7
.6
.4
.2
.0
.9
.7
.5
.1
.1
.1
.1
.7
.5
.2
.2
.1
.8
.6
.1
-0.35%
+0.58% -4.06%
.1
.9
.7
.6
.4
.2
.0
.9
.7
.5
.1
STA 14+00 TO STA 24+00
PROFILE SHEET
SANITARY SEWER PROFILE
STORM SEWER PROFILE
BOND STREET
BOND STREET
POE STA 24+00
E D
G E
O F
C U
R B
POE STA 24+00
E D
G E
O F
C U
R B
EX. SAN MH
R
1284.14 15" NW
1284.21 10" S
1284.19 12" W EX INV:
1294.34RIM:
EX 4' DIA SAN MH - ADJ COVER Q
�STA 23+87, AT
1285.15 12" E
1285.20 12" W
1286.36 8" S INV:
1295.78RIM:
4' DIA SAN MH - COVER Q
�STA 19+90, AT
SAN 4
EX. 12" SAN (CLAY)
R
EX. 12" SAN (CLAY)
R
PROP 12" SAN @ 0.26%
PROP 12" SAN @ 0.24%
EX. SAN MH
ADJ-Q
(PVC)
EX. 12" SAN
S
FIELD VERIFY INV. 1284.19
PVC SANITARY
CONNECT TO EXISTING
FIELD VERIFY INV. 1286.58
CONNECT TO EX 8" SAN, 40' SOUTH
PROP 8" SAN @ 0.54% (EX SLOPE)
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
CENTERLINE
EX GRADE AT
AT CENTERLINE
PROPOSED PLAN GRADE
PROPOSED CENTERLINE PROFILE
EXISTING CENTERLINE PROFILE
STM 5
1290.50 18" SWINV:
1295.17RIM:
4' DIA STM CB (LEACHING) - COVER K
STA 20+35, 14' LT
STM 4
1290.50 18" NEINV:
1295.14RIM:
4' DIA STM CB (LEACHING) - COVER K
STA 20+07, 25.5' RT
PROP 18" STM
EX. STM CB
ADJ-K
RIM ELEV 1294.00
EX/PROP
PROP RIM ELEV 1294.00
EX RIM ELEV 1294.21
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
0 8
VERT. (FT)
HORZ. (FT)
HOUK
2200337
ALDRICH STREET IMPROVEMENTS
PLANS FOR BIDDING PURPOSES
19 20 21 22 23 24
19 20 21 22 23 24
RAILROAD CROSSING DETAILS
P&N JN:
DATE:
DESIGN:
SHEET6/23/2025
HOUK
2200337
NO SCALE
File details come from the government source that posted it. Updated .