This document is a comprehensive set of architectural sheets for the United States Forest Service (USFS) Sisters Ranger District Administrative Building project located in Sisters, Oregon. The architectural plans, prepared by Steele Associates Architects LLC, detail a 13,244 square foot administrative facility with multiple functional spaces including offices, meeting rooms, restrooms, corridors, a break room, and mechanical areas.
The architectural drawings include detailed floor plans, exterior elevations, roof plans, wall and window details, finish schedules, and site plans. Key design features include a mix of exterior materials such as fiber cement siding, stone veneer, and vertical wood siding, with a complex roof structure featuring multiple roof pitches and eyebrow elements. The building is designed with accessibility in mind, featuring ABA-compliant spaces, multiple entry points, and carefully planned interior circulation. The site plan shows parking areas, landscaping, picnic areas, and additional site infrastructure like bike racks, gates, and signage. The drawings are dated October 11, 2023, and represent a conformed set of architectural documents for construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CL
DRAWING NUMBER
DRAWING NAME
DRAWING SCALE
AA WINDOW/CURTAIN WALL DESIGNATION. SEE WINDOW SCHEDULE.
A101
A9
A
A9
A
DATUM TAGREVISION CLOUD & TAG
REVISION CLOUD
AROUND AREA OF
CHANGE
DELTA SYMBOL &
REVISION NUMBER
A101
? KEYNOTE.
A101
GRID HEAD
n
GLAZING DESIGNATION.
GLAZING MODIFIER
202A DOOR DESIGNATION. SEE DOOR SCHEDULE
FM9
WALL, FLOOR, CEILING, ROOF DESIGNATION. SEE APPROPRIATE TYPE
SHEETS.
WALL, FLOOR, BASE, CEILING FINISH TAG. THIS SYMBOL WHEN
ATTACHED TO A WALL SHALL INDICATE THIS FINISH FOR ENTIRE
LENGTH OF WALL FROM ONE INTERSECTION TO THE NEXT AND
NOT BE TERMINATED BY WINDOWS OR DOORS UNO.
Room name
ROOM NAME TAG
Ø
CENTER LINE
NUMBER
DEGREE
AND
AT
WORK POINT OR ELEV. BENCH MARK
DIAMETER OR ROUND
NORTH ARROW
SYMBOLS
DETAIL TAGS
DETAIL NUMBER
PAGE WHERE FOUND
DETAIL CUT LINE
DETAILED AREA
WALL SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
BUILDING SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
DRAWING TITLE
ELEVATION TAGS
PAGE
VIEW
ROOM FINISH TAG
FLOOR FINISH
CORRESPONDING
WALL FINISHES
BASE FINISH
MISCELLANEOUS KEYED NOTE SYMBOLS
ROOM NAME
ROOM NUMBER
ELEVATION DATUM
INDICATES ITEM OR
FLOOR LEVEL BEING
REFERENCED
A101
NAME
ELEVATION
NW
SW
EWWWFF BF
A101
1 View Name 1/8" = 1'-0"
METAL
EARTH
CONCRETE
CONCRETE
MASONRY UNIT
FINISHED WOOD MEMBER
PLYWOOD
BATT INSULATION
GYP. BOARD
CONTINUOUS WOOD
MEMBER
WOOD BLOCKING
PLASTER OR STUCCO
RIGID INSULATION
MINERAL WOOL
INSULATION
ALUMINUM
GRAVEL
STONE
METAL OR WOOD STUD FRAMED WALL
• WALL TYPE DESIGNATES WIDTH OF
WALL
• WIDTH OF WALL DIMENSIONED ONLY AT
1/4"=1' OR LARGER SCALE
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
METAL OR WOOD STUD FRAMED WALL W/
MASONRY OR STONE VENEER
• WIDTH OF WALL DIMENSIONED FROM
FACE OF MASONRY.
• WIDTH OF MASONRY WALL
DIMENSIONED FROM FACE OF STUD.
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
MASONRY WALL
• WIDTH OF WALL DIMENSIONED TO
NOMINAL SIZE.
• DOORS DIMENSIONED TO
CENTERLINE OF NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT MASONRY
OPENING.
CONCRETE WALL
• ACTUAL WIDTH OF WALL DIMENSIONED
• DOORS DIMENSIONED TO CENTERLINE
OF NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
NEW CONSTRUCTION
ALL NEW CONSTRUCTION IS SHOWN HATCHED & SHADED AS ILLUSTRATED BELOW.
ALL NEW CONSTRUCTION IS FULLY NOTED AS SHOWN BELOW.
ALL WORK IS NEW UNLESS LABELED "EXISTING"
S T
R U
C T
U R
E
T O
P O
F
X 9A
4'-0"
G R
ID
T O
G R
ID
T O
G R
ID
T O
4'-0"
4'-0"
4M
5J
OF STRUCTURE
RIGHT SIDE
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M E
D
S
T
O
C T
O B
E R
/1
/2
:2
:2
P M
A001
AS/STSsho
20145.01
G E
N E
R A
L N
O T
E S
L E
G E
N D
S A
B B
R E
V
IA
T
IO
N S
GENERAL NOTES
LEGENDS
ABBREVIATIONS
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
NEW MATERIALS LEGEND (TYPICAL SECTION VIEWS)
SYMBOLS GENERAL NOTES:ABBREVIATIONS:
DIMENSIONING LEGEND (TYPICAL PLAN VIEWS)
24 THE GC SHALL PROVIDE AND INSTALL FIRE EXTINGUISHERS WHERE SHOWN ON
PLAN.
25 MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM
TO THE BUILDING CODE AND ALL APPLICABLE GOVERNING BUILDING
CODES/ORDINANCES. SEE CODE SUMMARY, SHEET G004.
26 THE GC SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND LIABLE FOR PUBLIC
AND EMPLOYEE PROTECTION AS NECESSARY AND AS REQUIRED BY THE CODES,
INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS. ALL WORK
SHALL CONFORM TO THE ORDINANCES AND REGULATIONS OF GOVERNMENTAL
AGENCIES HAVING JURISDICTION AT THE PROJECT.
27 THE GC SHALL PROVIDE TEMPORARY BARRICADES FOR DUST AND NOISE
CONTROL, AND ALL REQUIRED ENVIRONMENTAL PROTECTION WHERE WORK
JOINS EXISTING CONDITIONS.
28 ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT
IN A CLEAN (BROOM) CONDITION DAILY.
29 GC SHALL PREPARE AND IMPLEMENT AN INDOOR AIR QUALITY PROGRAM TO BE
INSTITUTED DURING CONSTRUCTION ACTIVITIES.
30 GC SHALL PREPARE AND IMPLEMENT A CONSTRUCTION WASTE MANAGEMENT
AND RECYCLING PLAN, TO BE PROVIDED TO THE OWNER.
31 GC SHALL AVOID UNNECESSARY DISRUPTIONS TO THE FUNCTIONS AND/OR DAILY
ACTIVITIES OF ADJACENT EXISTING SITES AND BUILDINGS.
32 CALL BEFORE YOU DIG! OREGON LAW REQUIRES THE GENERAL CONTRACTOR TO
CONTACT THE "OREGON UTILITY NOTIFICATION CENTER" AT 1 (800) 332-2344 OR 1
(503) 232-1987, NO LESS THAN TWO (2) BUSINESS DAYS, BUT NO MORE THAN TEN
(10) BUSINESS DAYS BEFORE COMMENCING ANY EXCAVATION. LOCATE ALL
UNDERGROUND UTILITIES BEFORE STARTING ANY BELOW GRADE WORK. THE
GENERAL CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT
OF IDENTIFIED UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN
CONJUNCTION WITH THE EXECUTION OF THE WORK.
33 PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR NOTIFYING THE ARCHITECT OF ANY EXISTING DAMAGE TO THE NEIGHBORING
SUITES, NEW OR EXISTING SITE IMPROVEMENTS, ETC. FAILURE TO DO SO SHALL
PLACE THE GENERAL CONTRACTOR WITH THE SOLE RESPONSIBILITY FOR
CORRECTING SUCH DAMAGE.
34 APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION.
THE GENERAL CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE
COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS,
ON THE PREMISES AT ALL TIMES. THESE ARE TO BE KEPT UNDER THE CARE OF
THE JOB SUPERINTENDENT.
35 THE GC IS TO PROVIDE BLOCKING AS REQUIRED FOR MOUNTING OF WALL
MOUNTED SHELVES, CABINETS, HC GRAB BARS AND PARTITION BRACES AND ALL
OTHER ITEMS IDENTIFIED ON THE EQUIPMENT OR ACCESSORY SCHEDULE.
BLOCKING SHALL BE FIRE TREATED WHERE REQUIRED BY THE BUILDING CODE.
36 THE GC IS RESPONSIBLE FOR RECEIVING, UNLOADING, UNCRATING,
INSTALLATION AND HOOK-UP OF ALL CONTRACTING OFFICER FURNISHED ITEMS
UNLESS NOTED OTHERWISE ON THE DRAWINGS.
37 THE GC IS TO ASSURE THAT NO REBAR OR REINFORCEMENT IS PRESENT PRIOR
TO CORE DRILLING OR PLACING BOLTS OR ANY OTHER ITEM WHICH COULD
DISTURB THE STRUCTURAL SLAB OR FOUNDATION WALLS.
38 PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE
REQUIRED.
39 PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER AND DRYWALL
SURFACES WHERE IT TERMINATES OR MEETS ANY DISSIMILAR MATERIAL, UNLESS
NOTED OTHERWISE.
40 PROVIDE METAL CORNER TRIM AT ALL OUTSIDE CORNERS OF PLASTER AND
DRYWALL SURFACES.
41 ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED
WITH APPROPRIATE SEALANT MATERIAL.
42 UNLESS OTHERWISE NOTED, ALL EXTERIOR AND INTERIOR METAL, TRIM,
TREILLAGE, RAILINGS, MOLDINGS, FRAMES, CASTING ETC., SHALL BE PAINTED.
43 FIXTURES AND EQUIPMENT SHOWN ARE FOR COORDINATION PURPOSES ONLY.
REFER TO THE MANUFACTURER'S PRODUCT DATA AND THE MECHANICAL AND/OR
ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR FIXTURE AND EQUIPMENT
DESCRIPTIONS, LOCATIONS AND INSTALLATION REQUIREMENTS.
44 THE GC SHALL VERIFY LOCATIONS OF ALL CEILING ACCESS PANELS WITH
MECHANICAL, FIRE SPRINKLER AND PLUMBING PLANS. ACCESS PANELS SHALL BE
FURNISHED AND INSTALLED WITH A FIRE RATING EQUAL TO THE WALL OR CEILING
ASSEMBLY INTO WHICH THEY ARE TO BE INSTALLED. FINISH AND LOCATION
SHALL BE APPROVED BY THE CONTRACTING OFFICER.
45 THE GC SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT PADS & BASES WITH
EQUIPMENT MANUFACTURERS & SHALL VERIFY ALL SIZES AND LOCATIONS OF
DUCT OPENINGS ON ROOF AND INTERIOR SHAFTS.
46 SYSTEMS SHOWN ON THE DRAWINGS ARE INTENDED TO BE FINISHED, INSTALLED
AND TURNED OVER TO THE CONTRACTING OFFICER IN PROPER FUNCTIONING
CONDITION. ALL WORK IS TO BE CONSIDERED IN CONTRACT SUM.
47 WHERE DAMAGE TO INSTALLED FINISHES OCCURS DURING CONSTRUCTION, THE
CONTRACTOR SHALL RESTORE SUCH FINISHES AS SPECIFIED OR SCHEDULED, TO
MATCH ADJACENT SURFACES.
48 CUTTING AND PATCHING: WHETHER OR NOT SHOWN ON THE DRAWINGS, THE
CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF WORK THAT
MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND
SHALL NOT ENDANGER ANY IN-PLACE WORK BY CUTTING, EXCAVATING OR
OTHERWISE ALTERING THE WORK OR ANY PART OF IT. ALL PATCHING, REPAIRING
AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN EXECUTION
OF THE WORK SHALL BE REPLACED WITH APPLICABLE MATERIALS SO THAT
SURFACES WILL, UPON COMPLETION, MATCH SURROUNDING SIMILAR SURFACES
IN FIT, FINISH AND COLOR.
1 THE GENERAL CONTRACTOR SHALL HEREAFTER BE REFERRED TO AS GENERAL
CONTRACTOR OR "GC". THE CONTRACTING OFFICER MAY HEREAFTER BE
REFERRED TO AS "CONTRACTING OFFICER".
2 PLEASE NOTE:THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK
REGARDLESS OF THE LOCATION OF THE INFORMATION IN THE DOCUMENTS. THE
GENERAL CONTRACTOR SHALL UTILIZE THE CONSTRUCTION DRAWINGS AND
WRITTEN SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE
COMPLETE CONSTRUCTION OF THIS PROJECT. ITEMS LISTED IN DRAWINGS MAY
NOT BE INCLUDED IN SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS MAY NOT
BE INCLUDED IN DRAWINGS.
3 GC SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN TRADES.
4 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING
NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION
OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE CONSTRUCTION
DOCUMENTS. THE GC SHALL PROVIDE AND INSTALL ALL ACCESSORIES,
COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK DEPICTED OR
SPECIFIED.
5 THE INDIVIDUAL DISCIPLINE DRAWINGS (A, C, E, ETC.) ARE PART OF A LARGER SET
OF DRAWINGS, WHICH, WHEN COMPLETE, CONSISTS OF DRAWINGS LISTED IN THE
"DRAWING INDEX." PARTIAL SETS OF DRAWINGS NOT INCLUSIVE OF ALL
DISCIPLINES ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED.
6 CONSTRUCTION DOCUMENTS CONSIST OF DRAWINGS AND SPECIFICATIONS.
CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY REVIEW ALL DRAWINGS
AND SPECIFICATIONS IN THIS PROJECT AND BECOME FAMILIAR WITH ALL
STRUCTURES, FIXTURES AND EQUIPMENT TO BE INSTALLED. COORDINATE ALL
ASPECTS OF THE CONSTRUCTION WITH ALL TRADES ON THE JOB TO ENSURE
THAT ALL MATERIALS AND LABOR REQUIRED TO PROVIDE A COMPLETE AND
OPERATIONAL FACILITY ARE INCLUDED IN THE BID.
7 THE GC SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO
BEGINNING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND
MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS. THE GC SHALL
ACCEPT PREMISES AS FOUND. CONTRACTING OFFICER WILL MAINTAIN THE
EXISTING
8 THE GC AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL AND
LANDSCAPE AND OTHER PROJECT RELATED DOCUMENTS PRIOR TO
CONSTRUCTION.
9 DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT
INTENDED. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE CONTRACTING
OFFICER ANY SUCH DISCREPANCIES PRIOR TO COMMENCING WORK.
10 DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS: DO NOT SCALE DRAWINGS TO
DETERMINE ANY LOCATIONS. THE CONTRACTING OFFICER SHALL BE NOTIFIED OF
ANY DISCREPANCY PRIOR TO CONTINUING WITH WORK.
11 WHERE A DETAIL CALL OUT DESCRIBES A TYPE OF CONDITION, IT APPLIES TO ALL
SIMILAR CONDITIONS, WHETHER OR NOT A DETAIL TAG IS SHOWN AT THAT
LOCATION ON THE PLANS.
12 ALL PLAN DIMENSIONS ARE FROM GRIDLINE OR FACE OF STUD OR FACE OF
BLOCK UNLESS OTHERWISE INDICATED. SEE SECTION ON "DIMENSIONING" THIS
SHEET.
13 DIMENSIONS INDICATED TO BE "CLEAR" OR "CLR." ARE DIMENSIONS TO THE
FINISHED SURFACE OF THE WALL OR ASSEMBLY.
14 THE GC SHALL REPORT TO THE CONTRACTING OFFICER ALL CONDITIONS
REQUIRING COORDINATION/ CHANGES WITH THE CONTRACT DOCUMENTS.
COORDINATION / APPROVAL SHALL TAKE PLACE BEFORE THE WORK BEGINS. ALL
CHANGES TO THE CONTRACT COST SHALL BE APPROVED THROUGH A CHANGE
ORDER.
15 DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER
SMALL SCALE DRAWINGS.
16 THE CONTRACTING OFFICER WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR
CONFORMANCE WITH DESIGN CONCEPT OF THE PROJECT. THE CONTRACTING
OFFICER'S REVIEW OF A SEPARATE ITEM SHALL NOT INDICATE APPROVAL OF AN
ASSEMBLY IN WHICH THE ITEM FUNCTIONS. THE CONTRACTING OFFICER WILL
NOT REVIEW SHOP DRAWINGS UNTIL THE GC HAS REVIEWED AND STAMPED THE
SHOP DRAWING/SUBMITTAL. THE GC IS RESPONSIBLE FOR FIELD VERIFYING ALL
DIMENSIONS SHOWN ON THE SHOP DRAWINGS. THE CONTRACTING OFFICER'S
REVIEW OF THE SHOP DRAWINGS SHALL NOT OVERRIDE THE CONDITIONS
DESCRIBED IN THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY NOTED
OTHERWISE BY THE CONTRACTING OFFICER.
17 FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S
STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
18 FOR GRADING, TRENCHING ETC., CONTACT THE CONTRACTING OFFICER FOR
INSTRUCTIONS PRIOR TO THE CONTINUATION OF WORK SHOULD ANY UNUSUAL
CONDITIONS BECOME APPARENT DURING GRADING OR FOUNDATION
CONSTRUCTION. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE
VERIFIED BY THE GENERAL CONTRACTOR BEFORE CONSTRUCTION.
19 ALL WORK, MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE
CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES
HAVING JURISDICTION AT THE PROJECT LOCATION. THE GENERAL CONTRACTOR
MUST COMPLY WITH THE CONTRACTOR REGISTRATION REQUIREMENTS OF ALL
GOVERNING AUTHORITIES.
20 ALL PROJECT CONSTRUCTION SHALL CONFORM WITH THE ARCHITECTURAL
BARRIERS ACT (ABA) 2015.
21 THE GC SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING AUTHORITIES AND
UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING INSPECTION.
22 THE GC SHALL MAINTAIN ALL REQUIRED EXITS AND FIRE LANES IN WORKING
ORDER.
23 A GENERAL BUILDING PERMIT WILL BE SECURED BY THE UNITED STATES FOREST
SERVICE. ALL OTHER PERMITS OR CONNECTION FEES SHALL BE SECURED BY
THE GENERAL CONTRACTOR AND REIMBURSED THROUGH THE CONTRACTING
OFFICER.
SUSP SUSPENDED
SYM SYMMETRICAL
TEL TELEPHONE
TEMP TEMPERED
THK THICK
T&G TONGUE & GROOVE
TBC TOP BACK OF CURB
T.O.C. TOP OF CONCRETE OR
CURB
T.O.F TOP OF FOOTING
T.O.P. TOP OF PARAPET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TDC TRAFFIC DECK COVERING
T TREAD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
V.I.F. VERIFY IN FIELD
VER VERTICAL
WC WATER CLOSET
WL WATER LEVEL
WP WATERPROOFING
W WIDE
W/ WITH
WD WOOD
WP WORKING POINT
WI WROUGHT IRON
(N) NEW
NR NON-RATED
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. NUMBER
OFF OFFICE
OC ON CENTER
OPN'G OPENING
OCC OPERATOR CONTROL
CENTER
OPP OPPOSITE
OH OPPOSITE HAND
OD OUTSIDE DIAMETER
OF OVERFLOW
OFI OWNER FURNISH ITEM
OFOI OWNER FURNISHED OWNER
INSTALLED
PR PAIR
PLAS PLASTIC
PL PLATE
PLWD PLYWOOD
PC PORTLAND CEMENT
PREP PREPARATION
PT PRESSURE TREATED
PTDF PRESSURE TREATED
DOUGLAS FIR
PROJ PROJECTION
QT QUARRY TILE
REF FREFERENCE
R OR RAD RADIUS
REDW'D REDWOOD
REFL REFLECTED
REINF REINFORCE
REQ'D REQUIRED
RES RESILIENT
RR RESTROOM(S)
R RISER
RD ROOF DRAIN
RTU ROOF TOP UNIT
RM ROOM
R.O. ROUGH OPENING
SECT SECTION
SHT SHEET
SIM SIMILAR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STG STORAGE
STRUCT STRUCTURAL
SIMUL SUMULATED
EXIST EXISTING
EJ EXPANSION JOINT
EXT EXTERIOR
FOC FACE OF CONCRETE
FOS FACE OF STUD
FOW FACE OF WALL
FT FEET
FRP FIBER REINFORCED
PLASTIC
FIN FINISH
FF FINISH FLOOR
FO FINISHED OPENING
FHC FIRE HOSE CABINET
FLR FLOOR
FD FLOOR DRAIN
FS FLOOR SINK
FDN FOUNDATION
FH FULL HEIGHT
FS FULL SIZE
FSD FULL SIZE DETAIL
GALV OR GV GALVANIZED
GA GAUGE
GC GENERAL CONTRACTOR
GL GLASS
GFRC GLASS FIBER REINFORCED
CONCRETE
GR GRADE
GYP. BD. GYPSUM BOARD
HDWD HARDWOOD
H HIGH
HP HIGH POINT
HM HOLLOW METAL
HORIZ HORIZONTAL
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
LAV LAVATORY
LEV LEVEL
LTWT LIGHT WEIGHT
LTG LIGHTING
MAINT MAINTENANCE
MFG MANUFACTURER
MO MASONRY OPENING
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MB MECHANICAL BOLT
MET METAL
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MULL MULLION
ABBREV ABBREVIATION (S)
ABB ABBREVIATION (S)
A.F.F. ABOVE FINISHED FLOOR
AD ACCESS DOOR
ACOUS ACOUSTICAL
A/C AIR CONDITIONING
ALUM ALUMINUM
AB ANCHOR BOLT
APPR APPROVED
AC ASPHALT CONCRETE
BM BEAM
BLK BLOCK
BD BOARD
BOT BOTTOM
B.O.B. BOTTOM OF BEAM
BLDG BUILDING
CLG CEILING
CH CEILING HEIGHT
CEM CEMENT
C/C CENTER TO CENTER
CER CERAMIC
CLR CLEAR
CLOS CLOSET
COL COLUMN
COMPO COMPOSITION
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONN CONNECTION
CONT CONTINUOUS
CORD COORDINATE
CORR CORRIDOR
CSK COUNTERSINK
DEL DELETE
DET DETAIL
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DR DOOR
DO DOOR OPENING
DBL DOUBLE
DF DOUGLAS FIR
DN DOWN
DS DOWNSPOUT
DWG DRAWING
DF DRINKING FOUNTAIN
EA EACH
EWC ELECTRIC WATER COOLER
ELEC ELECTRICAL
ELEV OR EL ELEVATION
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
REV. DATE DESCRIPTION
F1
F2
COMPACTED GRAVEL
SUB-BASE, SEE GEOTECH
REPORT.
FINISH FLOOR PER PLAN
CONCRETE SLAB FLOOR -
SEE STRUCTURAL
DRAWINGS AND 03 30 00
UNDERSLAB VAPOR
BARRIER - SEE 03 00 00
FLOOR DECK - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
FLOOR JOISTS - SEE
STRUCTURAL DRAWINGS
AND 06 17 33
SECTION VIEW
SECTION VIEW
F3
FLOOR DECK - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
FLOOR JOISTS - SEE
STRUCTURAL DRAWINGS
AND 06 17 33
SECTION VIEW
(2) LAYERS 5/8" TYPE
'X' GYPSUM BOARD
FIRE RATING: 1-HR
REFERENCE: SIM. TO GA FILE No. FC 5406
R1
R2
ASPHALT COMPOSITION
SHINGLES - SEE 07 31 13
FULL FIELD ICE & WATER
SHIELD UNDERLAYMENT
R-30 RIGID INSULATION -
SEE 07 21 00
VAPOR BARRIER -
SEE 07 25 00
ROOF SHEATHING - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
ROOF FRAMING - SEE
STRUCTUAL DRAWINGS
AND 06 10 00
ASPHALT COMPOSITION
SHINGLES - SEE 07 31 13
FULL FIELD ICE & WATER
SHIELD UNDERLAYMENT
ROOF SHEATHING - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
ROOF FRAMING - SEE
STRUCTUAL DRAWINGS
AND 06 10 00
SOFFIT - SEE REFLECTED
CEILING PLAN
R3
ASPHALT COMPOSITION
SHINGLES - SEE 07 31 13
FULL FIELD ICE & WATER
SHIELD UNDERLAYMENT
ROOF SHEATHING - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
ROOF FRAMING - SEE
STRUCTUAL DRAWINGS
AND 06 10 00.
VARIES AT R3a.
SOFFIT - SEE REFLECTED
CEILING PLAN
VAPOR BARRIER -
SEE 07 25 00
R-30 RIGID INSULATION -
SEE 07 21 00
R4
SINGLE-PLY MEMBRANE
ROOFING - SEE 07 54 00
ROOF SHEATHING - SEE
STRUCTURAL DRAWINGS
AND 06 10 00
ROOF FRAMING - SEE
STRUCTUAL DRAWINGS
AND 06 10 00
R-49 BATT INSULATION -
SEE 07 21 00
VAPOR BARRIER
MEMBRANE - SEE 07 25 00
SECTION VIEW
SECTION VIEW
SECTION VIEW
SECTION VIEW
INSULATION COVER BOARD -
07 2100
INSULATION COVER BOARD -
07 2100
SELF-ADHERING
WATER-RESISTIVE AIR
BARRIER MEMBRANE.
2x6 FRAMING @ 16" O.C.
R-21 BATT INSULATION
VAPOR RETARDER. SEE 07
25 00.
5/8" GYP. BD. PAINT
1-1/2" CONTINUOUS XPS
INSULATION BOARD (R-7.5.)
FIBER CEMENT LAP SIDING.
SEE FINISH SCHEDULE &
SPECIFICATIONS.
SELF-ADHERING
WATER-RESISTIVE AIR
BARRIER MEMBRANE.
2x6 FRAMING @ 16" O.C.
R-21 BATT INSULATION
VAPOR RETARDER. SEE 07
25 00.
5/8" GYP. BD. PAINT
1-1/2" CONTINUOUS XPS
INSULATION BOARD (R-7.5.)
6L
6F
6L
RAINSCREEN SYSTEM -
INSTALL PER MFR'S
WRITTEN INSTRUCTIONS.
SEE 07 46 46.
EXT. WALL SHEATHING -
SEE STRUCTURAL
DRAWINGS.
FIBER-CEMENT BOARD
& BATTEN SIDING -
SEE 07 46 46.
RAINSCREEN SYSTEM -
SEE 07 46 46.
EXT. WALL SHEATHING - SEE
STRUCTURAL DRAWINGS
6E
BATTERED STONE VENEER
BELOW. SEE EXTERIOR
ELEVATIONS AND WALL
SECTIONS ON SHEET A310
2x6 STUDS - SEE
STRUCTURAL DRAWINGS
1/2" RESILIENT CHANNELS
@ 24" O.C., HORIZONTAL
5/8" GYPSUM BOARD,
BOTH SIDES
5-1/4" ACOUSTICAL
BATT INSULATION
6J
FIRE RATING: N/A
STC RATING: 45-49
REFERENCE: SIM. TO GA FILE No. WP 3335
/4
2x6 STUDS - SEE
STRUCTURAL DRAWINGS
5/8" GYPSUM BOARD ON
ROOM SIDE
STONE VENEER WAINSCOT
FIBER-CEMENT SIDING
2x6 FRAMING @ 16" O.C.
R-21 BATT INSULATION
5/8" GYP. BD. PAINT
1-1/2" CONTINUOUS XPS
INSULATION BOARD (R-7.5.)
EXT. WALL SHEATHING - SEE
STRUCTURAL DRAWINGS
BATTERED STONE VENEER
BELOW. SEE EXTERIOR
ELEVATIONS AND WALL
SECTIONS ON SHEET A310
VAPOR BARRER -
SEE 07 25 00
WEATHER BARRIER -
SEE 07 25 00
MASONRY WIRE TIES -
SEE 04 43 13
STONE VENEER TO TOP PLATE
PLAN VIEWPLAN VIEW
PLAN VIEW
PLAN VIEW
PLAN VIEW
2x6 STUDS - SEE
STRUCTURAL DRAWINGS
1/2" RESILIENT CHANNELS
@ 24" O.C., HORIZONTAL
5/8" GYPSUM BOARD,
BOTH SIDES
5-1/4" ACOUSTICAL
BATT INSULATION
6B
FIRE RATING: N/A
STC RATING: 45-49
REFERENCE: SIM. TO GA FILE No. WP 3335
/4
PLAN VIEW
BALLISTICS RESISTANT
PANEL - SEE 10 26 41. PUBLIC SIDE OF LOBBY
& RECEPTION SPACES
NON-PUBLIC SIDE OF LOBBY
& RECEPTION SPACES
2x6 STUDS - SEE
STRUCTURAL DRAWINGS
5/8" TYPE 'X' GYPSUM
BOARD, BOTH SIDES
5-1/4" ACOUSTICAL
BATT INSULATION
6C
FIRE RATING: 1-HR
STC RATING: 45-49
REFERENCE: SIM. TO GA FILE No. WP 3514
/4
PLAN VIEW
(2) LAYERS OF TYPE 'X'
GYPSUM BOARD
1/2" HAT CHANNEL
CONNECTED TO STAIR
STRINGERS
STAIR, SEE
FLOOR PLAN AND
DETAILS ON A540
C1SECTION VIEW
FIRE RATING: 1-HR
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:2
P M
A010
AS/STSsho
20145.01
A S
S E
M B
L Y
T Y
P E
S
ASSEMBLY TYPES
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
ROOF TYPES
A. SEE SHEET A001 FOR GENERAL NOTES.
B. SEE TITLE SHEET FOR DRAWING INDEX.
C. DO NOT SCALE DRAWINGS.
D. CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE
CONTRACTING OFFICER ANY ERRORS, INCONSISTENCIES OR OMISSIONS
BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
E. TYPICAL ALL WALLS: EXTEND WALL TO STRUCTURE UN LESS OTHERWISE
NOTED. BRACE ALL OTHER WALLS TO STRUCTURE - SEE SHEET A530. EXTEND
GYP. BD. ON ONE SIDE OF WALL TO UNDERSIDE OF STRUCTURE ABOVE,
EXTEND GYPSUM BOARD TO 6" MIN ABOVE ADJACENT CEILING HEIGHT AT
OPPOSITE SIDE OF WALL. TYPICAL U.N.O.
F. FOR ACOUSTICALLY RATED WALLS: EXTEND WALL TO DECK AND GYPSUM
BOARD ON BOTH SIDES OF WALL. SEE TYPICAL ACOUSTICAL WALL DETAILS ON
SHEET A530..
G. FOR FIRE RATED WALLS: EXTEND WALL & GYP. B.D TO DECK. SEE TYPICAL
FIRE RATED WALL DETAILS ON SHEET A530.
H. RESTROOM WALLS SHALL RECEIVE WATER & MOLD RESISTANT GYP. BD. TO
CEILING, U.N.O.
FLOOR & CEILING TYPESINTERIOR WALL TYPES EXTERIOR WALL TYPES GENERAL NOTES
N
P A
RK
IN
G
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
WM
WM
W S
WM
W S
T
S
CO
S
CO
S
CO
CO
S
C O
S
S
CO
CO
CO
CO
CO
E L
I RR
NO PARKING
NO PARKING
STORAGE BUILDING
(UNDER SEPARATE
PERMIT)
PRO
PO
SED BUILDING
13,244 SF INT.
AREA
S A N
TIA
M H
IG
H W
A Y
M
IN
.24 '-0
M
IN.
24'-0"
M
IN
'-0
M
IN
.24 '-0
N O
R T
H P
IN
E
S T
R E
E T
W. MAIN
STREET
W. ADAMS
STREET
12 10'-0"
'-0
9'-0" 19 '-0
9'-0"
'-0
'-0
'-0
'-0
6 9
19'-0" 9'
-0 "19'-0"
9' -0
/8
19'-0"
9'-0"
'-0
9'-0"
'-0
9'-0"
'-0
9'-1"
'-0
'-0
12'-0"
MECH. EQUIP.
ELEC. EQUIP.
A
B
B
A102
A3
A102
A3
A102
A3
A102
B2
SLIDING GATE #2
SLIDING GATE #1
PERSONNEL
GATE
A103
C2
A103
C2
A103
B2
A103
B2
A103
A3
INFORMATION
KIOSK
A103
D2CHAIN LINK
FENCE DETAIL
'-0
19'-0"
31'-6"
EXISTING BUILDING
NEW BUILDING
NEW FENCE
PROPERTY LINE
ACCESSIBLE PATH TO
PUBLIC R.O.W.
LANDSCAPE AREA
PREVIOUS WORK UNDER
SEPRATE PERMIT
PHASE 2 WORK UNDER
THIS PERMIT - SEE CIVIL
DRAWINGS FOR EXTENT
PHASE 3 WORK UNDER
THIS PERMIT - SEE CIVIL
DRAWINGS FOR EXTENT
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:3
P M
A100
AS/STSjm/sho
20145.01
A R
C H
IT
E
C T
U R
A L
S
IT
E P
L A
N
ARCHITECTURAL SITE
PLAN
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
1" = 50'-0"
D5 SITE PLAN
SITE DATA:
1 COVERED BIKE PARKING, SEE DETAILS ON A101.
2 TRASH ENCLOSURE, SEE CIVIL PLANS ON C20.1 FOR
LOCATION. SEE A101 FOR CONSTRUCTION DETAILS.
3 PICNIC TABLE CANOPY, SEE CIVIL DRAWINGS FOR
LOCATION. SEE A101 FOR CONSTRUCTION DETAILS.
4 ACCESSIBLE RAMP W/ NON-SLIP FINISH AND
GUARDRAILS. SEE CIVIL PLANS ON C20.1.
5 PERSONNEL GATE IN FENCE.
6 GATE ACCESS CARD READER. SEE CIVIL AND
ELECTRICAL DRAWINGS. COORDINATE WORK WITH
DOOR HARDWARE INSTALLER.
7 ACCESSIBLE PARKING AND AISLE SIGNS, SEE DETAILS
ON A101.
8 ACCESSIBLE PARKING AND AISLE.
9 FLAGPOLE. SEE C4/A101 AND 10 75 00. PROVIDE POWER
FOR INTEGRAL DOWNIGHT.
10 EXISTING FIRE LEVEL CONDITION SIGN TO BE REMOVED
AND RELOCATED.
11 EXISTING SMOKEY BEAR SIGN TO BE REMOVED AND
RELOCATED.
12 INSTALL EXISTING SMOKEY BEAR SIGN IN THIS
LOCATION.
13 INSTALL EXISTING FIRE LEVEL CONDITION SIGN IN THIS
LOCATION.
14 REMOVE EXISTING RANGER DISTRICT AGENCY SIGN,
PRESERVE EXISTING MASONRY BASE AND SUPPORT
POSTS. INSTALL NEW AGENCY SIGN PER DETAIL
B4/A103.
GENERAL NOTES:
0' 50'25' 150'100'
SCALE : 1" = 50'-0"
n
KEYED NOTES:
A. SEE SHEET A001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. SEE TITLE SHEET FOR DRAWING INDEX.
C. DO NOT SCALE DRAWINGS.
D. REFER TO SHEETS A101, A102 & A103 FOR SITE RELATED DETAILS
E. CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE
CONTRACTING OFFICER ANY ERRORS, INCONSISTENCIES OR OMISSIONS
BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
F. CONTRACTOR SHALL REVIEW AND COMPLY WITH THE REQUIREMENTS OF
CHAPTER 33 OF THE OREGON STRUCTURAL SPECIALTY CODE,
"SAFEGUARDS DURING CONSTRUCTION' PRIOR TO COMMENCING ANY
CONSTRUCTION ACTIVITIES.
G. ALL SIGNAGE UNDER SEPARATE PERMIT
H. REFER TO CIVIL DRAWINGS FOR HORIZONTAL CONTROL INFORMATION,
DRAINAGE, SLAB AND PAVING ELEVATIONS.
I. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND SLAB DESIGN.
J. REFER TO ELECTRICAL & LANDSCAPE DRAWINGS FOR ADDITIONAL SITE
INFORMATION.
K. FOLLOW ALL RECOMMENDATIONS AND REQUIREMENTS OF THE
GEOTECHNICAL INVESTIGATION UNLESS MORE STRINGENT
REQUIREMENTS APPEAR IN THE CONTRACT DOCUMENTS AND
SPECIFICATIONS.
L. LIMITS OF WORK: THE CONTRACTOR SHALL CONFINE OPERATIONS AT THE
SITE TO AREAS PERMITTED BY LAW, ORDINANCES, PERMITS AND THE
CONTRACT DOCUMENTS. CONTRACTOR SHALL NOT UNREASONABLY
ENCUMBER THE SITE WITH MATERIALS AND/ OR EQUIPMENT.
M. STAGING AREA: THE CONTRACTOR AND SUBCONTRACTORS SHALL LIMIT
STORAGE OF MATERIALS AND LOCATIONS OF PORTABLE FIELD OFFICES AS
APPROVED BY THE CONTRACTING OFFICER.
N. GENERAL CONTRACTOR SHALL TAKE CARE NOT TO DAMAGE OR DISRUPT
EXISTING UTILITIES WHILE EXCAVATING, GRADING OR DIGGING DURING
CONSTRUCTION. CONFIRM LOCATION OF EXISTING UTILITIES OF ADJACENT
PROPERTIES BEFORE YOU DIG.
K. UNLESS NOTED OTHERWISE, SIDEWALKS AND RAMPS SHALL BE
CONSTRUCTED TO THE FOLLOWING REQUIREMENTS:
a. MAXIMUM CROSS SLOPE OF SIDEWALKS: 1:50
b. MAXIMUM SLOPE OF SIDEWALKS: 1:20
c. MAXIMUM SLOPE OF RAMPS: 1:12
d. MAXIMUM SLOPE OF ACCESIBLE PARKING STALLS 2% IN ANY
DIRECTION
L. PRIOR TO CONTRACTOR REQUESTING A BUILDING DEPARTMENT
FOUNDATION INSPECTION, THE SOILS CONTRACTING OFFICER SHALL
ADVISE THE BUILDING OFFICIAL IN WRITING THAT:
a. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE
SOILS REPORT.
b. THE UTILITY TRENCHES HAVE BEEN BACK FILLED AND COMPACTED.
c. THE FOUNDATION EXCAVATIONS COMPLETE THE INTENT OF THE
SOILS REPORT.
M. PRIOR TO START OF WORK, THE CONTRACTOR SHALL COORDINATE WITH
EACH RESPECTIVE GOVERNING AUTHORITY IN VERIFYING THE LOCATION
(INVERT ELEVATIONS, HORIZONTAL CONTROLS, EASEMENTS) OF EXISTING
SANITARY AND STORM SEWERS, WATER, NATURAL GAS, ELECTRICAL,
FIBER OPTIC, TELEPHONE, OVERHEAD POWER LINES AND UTILITY
SYSTEMS BOTH ONSITE AND OFFSITE. THE CONTRACTOR SHALL
CAREFULLY COMPARE THE DOCUMENTS, NOTIFY THE CONTRACTING
OFFICER IMMEDIATELY IF THE CONTRACTOR BELIEVES THAT A CONFLICT
WILL IMPACT THE CONTRACT PRICE AND/ OR THE CRITICAL PATH OF THE
CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL PROVIDE THE
FOLLOWING:
a. PRELIMINARY ADDITIONAL COST.
b. PRELIMINARY ADDITIONAL CALENDAR DAYS NEEDED.
c. DETERMINE IF A RECOVERY SCHEDULE CAN BE INSTALLED.
N. EMERGENCY VEHICLE ACCESS: THE CONTRACTOR SHALL MAINTAIN FIRE
TRUCK ACCESS TO THE EXISTING BUILDINGS THROUGHOUT THE
CONSTRUCTION PROCESS.
PROJECT INFORMATION
TAX LOT NUMBER 151005D000300
ZONING DISTRICT PF (PUBLIC FACILITY)
SITE AREA 11.22 ACRES
BUILDING AREA 13,244 SF
OFF STREET PARKING
STANDARD STALLS 112 STALLS
(6 ABA STALLS, 4 STAFF, 2 VISITOR)
LARGE STALLS 12 STALLS
RV STALLS 4 STALLS
HEAVY EQUIPMENT STALLS 4 STALLS
TOTAL: 132 STALLS
LEGEND:
CONCRETE FOOTING;
SEE STRUCTURAL
DRAWINGS3
DIA.
1'-6"
PAVING OR CONCRETE;
SEE SITE DRAWINGS
SLOPE CONCRETE BASE
@ EXTERIOR LOCATIONS.
4 1/2" STD. GALV. STEEL
TUBE;
APPLY TWO COATS
EXTERIOR HIGH
PERFORMANCE COATING;
SEE FINISH LEGEND
M
IN
RESERVED
PARKING
ACCESSIBLE
STATE DISABLED
PARKING PERMIT
REQ'D
/2
ACCESSIBLE PARKING SIGN
MODEL #R7-801
BARRIER FREE SYMBOL
6" 6"
FASTEN WITH (2) SIGN MOUNT
U-BOLT CLAMPS FROM
AMERICAN BARRICADE
COMPANY #2U-15
VAN ACCESSIBLE SIGN
MODEL #R7-8A 12x6
GREEN/WHITE FASTEN WITH (1)
SIGN MOUNT U-BOLT CLAMP
2 3/8" DIAMETER SCHEDULE 40
GALVENIZED PIPE POST -
EXTEND INTO FOOTING 2'-0"
1'-0" DIAMETER X 3'-0"
CONCRETE BASE
FINISH GRADE
M
IN
VAN
1'-6"
BLACK LETTERING &
BORDER ON WHITE
BACKGROUND
FADE RESISTANT PRE-
MANUFACTURED 12" x 18" x 1/8" BONDERIZED
STEEL SIGN
CARPOOL
PARKING
ONLY
OBTAIN PASS INSIDE
GREEN LETTERING &
BORDER ON WHITE
BACKGROUND
FADE RESISTANT PRE-
MANUFACTURED 12" x 18" x 1/8" BONDERIZED
STEEL SIGN
VEHICLE GRAPHIC IN
BLACK
FUEL
EFFICIENT
VEHICLE
PARKING ONLY
CONCRETE FOOTING
PER MFR ENGINEERED
DRAWINGS.
PREFINISHED ALUMINUM
FLASH COLLAR
35'-0" TALL COMMERCIAL
FLAG POLE; SEE
SPECIFICATIONS
LIGHTNING GROUND
SPIKE
STEEL BASE PLATE
SUPPORT PLATE
STEEL CENTERING
WEDGES (AS REQ'D)
FOUNDATION SLEEVE
FILLED W/ DRY TAMPED
SAND
LANDSCAPING; SEE SITE
DRAWINGS
M
IN
P O
L E
M F
G
C O
O D
W
IT
H
6" 6"
6"
1'-6" DIA CONCRETE FOOTING
PAVING.
6" DIA CONCRETE FILLED GALV
STL PIPE BOLLARD, HIGH
PERFORMANCE COATING, SEE
FINISH LEGEND.
TOP OF CONCRETE FOOTING TO
HAVE SMOOTH RADIUSED
CROWN
CROWN TOP OF CONCRETE
1/2" EXP JOINT (CIRCUMFERENCE)
5/8"x8" STELL BAR
THROUGH POST EACH WAY
NOTE: POUR BOLLARD
MONOLITHICALLY WITH
FOOTING
6 DIA CONCRETE FILLED GALV STL
PIPE BOLLARD, PAINTED
1'-6" DIA CONCRETE FOOTING
CONCRETE PAVING.
1/2" EXP JOINT (CIRCUMFERENCE)
SEALANT, TYP
SEALANT, TYP
NO
PARKING
ACCESS AISLE
ACCESSIBLE PARKING SIGN
MODEL #OR7-9
/2
6" 6"
FASTEN WITH (2) SIGN MOUNT
U-BOLT CLAMPS FROM
AMERICAN BARRICADE
COMPANY #2U-15
2 3/8" DIAMETER SCHEDULE 40
GALVENIZED PIPE POST -
EXTEND INTO FOOTING 2'-0"
1'-0" DIAMETER X 3'-0"
CONCRETE BASE
FINISH GRADE
M
IN
NO
PARKING
ACCESS AISLE
ACCESSIBLE PARKING SIGN
MODEL #OR7-9
/2
6" 6"
FASTEN WITH (2) SIGN MOUNT
U-BOLT CLAMPS FROM
AMERICAN BARRICADE
COMPANY #2U-15
SIGN #OR7-9A, POINTED
TOWARDS ACCESS AISLE
2 3/8" DIAMETER SCHEDULE 40
GALVENIZED PIPE POST -
EXTEND INTO FOOTING 2'-0"
1'-0" DIAMETER X 3'-0"
CONCRETE BASE
FINISH GRADE
M
IN
RESERVED
PARKING
VALID STATE
PERMIT REQ'D
ACCESSIBLE PARKING SIGN
MODEL #R7-801
BARRIER FREE SYMBOL
FASTEN WITH (2) SIGN
MOUNT U-BOLT CLAMPS
FROM AMERICAN
BARRICADE COMPANY #
2U-10
2 3/8" SQ. STEEL PIPE W/ 1/4" END
CAP WELDED TO TOP. GALV.
AFTER FABRICATION. PAINT
CHARCOAL GRAY.
FINISH GRADE
SLOPE CONCRETE AWAY
FROM STEEL PIPE.
8" DIA. x 24" DEEP MIN.
/2
6" 6"
M
IN
NO SMOKING
WITHIN 25 FEET
8"
CENTER PICTOGRAM ON
CENTERLINE OF SIGN
WHITE EXTERIOR
GRADE SIGN
3 1/2" DIA. PICTOGRAM,
RED
7/8" HIGH LETTERS,
DARK BROWN
1/4" WIDE DARK BROWN
STRIPE @ PERIMETER
/4
/4
/2
1/2" HIGH LETTERS,
DARK BROWN
CLEAR BIKE
PARKING AREA
GALVANIZED STEEL
PIPE BIKE RACK
6" ROUND ATTACHMENT
PLATE WITH (3) 1/2" DIA.
HOLES FOR ANCHOR
BOLTS
NOTE:
ALL BOLTS, WASHERS
AND NUTS SHALL BE
GALVANIZED STEEL
6'-0"
2'-6"
GALVANIZED STEEL
PIPE BIKE RACK -
SEE 32 33 13
ANCHOR PLATE - SEE
BIKE RACK - PLAN
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:3
P M
A101
AS/STSsho
20145.01
S
IT
E D
E T
A
IL
S
SITE DETAILS
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
3/4" = 1'-0"
D4 SITE - TYP. FENCE POST
1" = 1'-0"
D2 VAN ACCESSIBLE PARKING SIGN
1 1/2" = 1'-0"
C1 CARPOOL PARKING SIGNAGE
1 1/2" = 1'-0"
D1 FUEL EFFICIENT PARKING SIGNAGE
3/4" = 1'-0"
C4 FLAGPOLE BASE
3/4" = 1'-0"
A1 SAFETY BOLLARD
1" = 1'-0"
C3 ACCESS AISLE SIGNAGE
1" = 1'-0"
D3 ACCESS AISLE SIGNAGE
1" = 1'-0"
C2 ABA PARKING SIGNAGE
1 1/2" = 1'-0"
B1 NO SMOKING SIGN
1" = 1'-0"
A2 BIKE RACK - PLAN
1" = 1'-0"
B2 BIKE RACK - ELEVATION
A102
C2
9" 30'-0" 9"
31'-6"
/4
PAIR - 6'-0" x 6'-0" GATES
REC.REC.
REC.REC.
REC.
TRASH TRASH
DROP BOLT
SOCKET
6'-0" 6'-0" 12'-0" 6'-0"
GATE POST
CORNER
POST
EDGE OF CONCRETE
SLAB
CHAIN LINK FENCING -
SEE 32 31 13
LINE POSTS
CORNER POSTS
A102 D
/4
NO SMOKING SIGN -
SEE B2/A101
LOCKABLE LATCH
CANE BOLT TENSION WIRE, TYP.
@ TOP AND BOTTOM
STRETCHER BAR,
TYP. AT END POSTS
FINISH GRADE - SEE
SITE PLAN AND
CIVIL DRAWINGS
CANE BOLT
SOCKET
CONCRETE SLAB -
SEE CIVIL DRAWINGS
1'-6" dia. CONCRETE
FOOTING @ EACH POST
NO SMOKING SIGN -
SEE B2/A101
3/8" ROD w/ TURNBUCKLE, TYP. WHERE SHOWN
CORNER POST
TENSION WIRE
CHAIN LINK FENCING -
SEE 32 31 13
10'-0" @ TYPE B CANOPY
16'-0" @ TYPE A CANOPY
T Y
P E
B C
A N
O P
Y
T Y
P E
A C
A N
O P
Y
D5 A102
A
A
A
C5
11'-0" @ TYPE B CANOPY
17'-0" @ TYPE A CANOPY
T Y
P E
B C
A N
O P
Y
T Y
P E
A C
A N
O P
Y
6" 6"
6x6 CORNER POSTS - SEE
STRUCTURAL DRAWING
CONCRETE SIDEWALK,
WHERE IT OCCURS.
SEE SITE PLAN
LINE OF ROOF
OVERHANG ABOVE
LINE OF THICKENED
SLAB EDGE - SEE
STRUCTURAL DRAWINGS
CONCRETE SLAB - SEE
STRUCTURAL DRAWINGS
SEE SITE PLAN FLOR
LOCATIONS OF "A"
AND "B" CANOPIES
8-FT PICNIC TABLES -
BY OTHERS
D5 A102
FASCIA BOARD
EXPOSED
RAFTERS
2x6 T&G ROOF
DECKING
TRUSS
CORNER POST
EXPOSED RAFTERS
D5 A102
T Y
P
/4
LINE OF BEAMS BELOWRIDGE
LINE OF TRUSS BELOW
D5
A102 ROOFING TO MATCH
ADMIN BUILDING
1x3 FASCIA &
VERGE TRIM
2x 8 FASCIA &
VERGE BOARDS
GABLE END WALL
TRUSS WITH
HARDWARE TO
MATCH ADMIN. BLDG.
5" / 1 2"
5" / 12"
/8
ROOFING TO MATCH
ADMIN. BLDG.
CORNER POSTS -
SEE STRUCTURAL
DRAWINGS
PERIMETER ROOF
BEAM - SEE
STRUCTURAL
/4
ROOF FRAMING - SEE
STRUCTURAL DRAWINGS
BEAMS - SEE STRUCTURAL
PLYWOOD CEILING -
SEE REFLECTED
CEILING PLAN
CORNER POSTS -
SEE STRUCTURAL
CONCRETE SLAB -
SEE STRUCTURAL
16'-0"
END WALLS TRUSS
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:4
P M
A102
AS/STSsho
20145.01
S
IT
E D
E T
A
IL
S
SITE DETAILS
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
1/4" = 1'-0"
B2 TRASH ENCLOSURE PLAN 0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n n
MAGNETIC
NORTH
PROJECT
NORTH
1/4" = 1'-0"
C2 SOUTH ELEVATION TRASH ENCLOSURE
NORTH ELEVATION SIMILAR
1/4" = 1'-0"
D2 END ELEVATION TRASH ENCL.
1/4" = 1'-0"
A3 PICNIC CANOPY PLAN
1/4" = 1'-0"
C3 PICNIC CANOPY REFLECTED CEILING PLAN
1/4" = 1'-0"
D3 PICNIC CANOPY ROOF PLAN
1/4" = 1'-0"
A5 PICNIC CANOPY SIDE ELEVATION
1/4" = 1'-0"
C5 PICNIC CANOPY END ELEVATION
1/4" = 1'-0"
D5 PICNIC CANOPY SECTION
GATE LENGTH
28'-2 3/8"
C1 A103
D1 A103
CARD READER -
SEE SITE PLAN
6" STEEL BOLLARD, 3'-6"
HIGH, 2 REQUIRED -
SEE DETAIL A1/A101
CHAIN LINK
FENCE SYSTEM
PER SITE PLAN
GATE PHYSICAL
TRAVEL STOP
FREE EXIT
LOOP
DETECTOR
6" SAFETY
BOLLARD, 3'-6"
FIRE DEPARTMENT
KEY BOX
CURB/EDGE OF
PAVING - SEE
SITE PLAN
SLIDING CANTILEVER
GATE
S E C U R E S I D E
P U B L I C S I D E
EDGE OF PAVING
1'-6" PER GATE MFR. - L/2 MIN.
PER GATE MFR. = L + 2'-0"
PER SPEC & CIVIL DTLS.
GATE POSTS AND
CANTILEVER
HARDWARE
VERIFY IN FIELD
24'-0" - PAVED WIDTH
CONCRETE PAD CENTERED UNDER
GATE TRACK w/ SNOW MELT CABLE.
PAD TO BE 30" w xLENGTH OF GATE
TRACK.PROVIDE 2" RIGID
INSULATION UNDER PAD.
GATE PHYSICAL
TRAVEL STOP
CHAIN LINK FENCE
SYSTEM AND LINE POSTS
CONCRETE BASE/PAD. SIZE PER
MFR. WRITTEN INSTRUCTIONS
SAFETY BOLLARDS - SEE A1/A101
GATE OPERATOR W/ COLD
WEATHER PACKAGE INSTALL PER
MFR. WRITTEN INSTRUCTIONS
" P E
R C
A R
D
D
IM
R E
A D
E R
M F
R
PAINTED DIRECTIONAL
ARROWS
L/2 MINIMUM
PER GATE MFR.
NOTE: SAFETY
BOLLARDS NOT
SHOWN FOR
CLARITY
GATE POSTS
WITH CANITLEVER
GATE HARDWARE
GATE FRAME AND
BRACING BY GATE MFR.
GATE OPERATOR, REF.
TECHNOLOGY DRAWINGS 1/T501
DRIVE RAIL
CONCRETE BASE -
SIZED PER MFR
REQUIREMENTS
CONCRETE PAD UNDER
GATE TRACK - SEE B3/A103
D1 A103
GATE POSTS w/
CANTILEVER
HARDWARE
1'-0"
GATE OPERATOR ON
CONCRETE BASE,
REF. TECHNOLOGY
DRAWINGS 1/T501
SAFETY BOLLARD -
SEE B1/A11
CONCRETE PAD
CENTERED UNDER
GATE w/ SNOW MELT
CABLE - SEE B3/A103
PAVING - SEE CIVIL
DRAWINGS
1'-3" 1'-3"
LC
A103C1
2'-0"
1'-6"
DOOR CLOSER
DOOR POSITION SWITCH
2"x4"x3/8" TS DOOR SUPPORT FRAME w/
ANGLE STOPS
2-7/8" O.D. GATE
POST
EGRESS HARDWARE
ON SECURE SIDE
1/4" GLAV. PLATE
STEEL WELDED
TO DOOR.
HM FULL LITE DOOR
FOR EXTERIOR USE
1-5/8" O.D. TOP RAIL
2-7/8" GATE POST
2-3/8" O.D. LINE POST
ELECTRICAL LOCK /
ACCESS CONTROL,
REF. TECHNOLOGY
DRAWINGS 1/T501
1'-9"
PERSONNEL GATE
CARD READER WHERE
SHOWN ON SITE PLAN
5"x5"x3/16" TS
POST. PAINT PS1
FINISH GRADE
1" PVC CONDUIT
TO ACCESS PANEL
& CARD READER
PERFORATED GALV. METAL
PANEL w/ 1/2" STAGGERED
HOLES @ 1" O.C.
NOTE: GATE TO INCLUDE
PANIC HARDWARE, DOOR
CLOSER AND ELECTRIC STRIKE
2-7/8" O.D. CORNER
POST w/ STRETCHER
BAR, TYP.
CORNER POSTS
AND GATE POSTS
BRACE POSTS LINE POSTS
3/8" ROD w/ TURNBUCKLE
1-5/8" BOTTOM RAIL
1'-6" MIN. DIA.
CONCRETE FOOTING
FINISH GRADE
1'-0" MIN. DIA.
CONCRETE FOOTING
PRESSED STEEL RAIL
END AND BRACE BAND
GALVANIZED TENSION
WIRE WHERE FENCE
FABRIC IS BURIED
2-3/8" O.D. BRACE POSTS
1-5/8" O.D. TOP RAIL
9 GA. 2" MESH
CHAIN LINK FABRIC
PRIVACY SLATS -
COLOR AS
SELECTED BY
CONTRACTING
OFFICER
4'-2 1/2"
/4
4'-2 1/2"
/2
1'-6"
LINE OF ROOF ABOVE
LINE OF ROOF PURLIN
AND BEAM ABOVE
70°
LIGHT FIXTURE -
SEE ELECTRICAL
DRAWINGS
C3 A103
A105
B4
DISPLAY
BOARD
O.F./O.I.
(DASHED)
DISPLAY
BOARD
O.F./O.I.
(DASHED)
ROOF ASSEMBLY - SEE
DETAIL A4/A103
4x6 CEDAR PURLINS (TYP.
OF 3), FASTEN TO BEAMS
w/ 1/4"x6" SDS SCREWS IN
"TOE-NAIL"
CONFIGURATION
8x12 CEDAR #1 BEAM w/ CHAMFER AT
ENDS
6x6 CEDAR #1 POSTS
2x6x4'-9" CEDAR SLATS SPACED w/ 3-1/2"
CLEAR BTWN SLATS.
ATTACH TO FACE OF
POSTS.
LIGHT FIXTURE - SEE
ELECTRICAL
DRAWINGS
C3 A103
A103
D3
KIOSK, C.F.C.I.
DRIP EDGE FLASHING
ROOF ASSEMBLY PER
DETAIL __ / ____
SHEET METAL DRIP EDGE
4x6 CEDAR PURLINS
8x12 CEDAR #1 BEAM, CHAMFER ENDS
LIGHT FIXTURE - SEE
ELECTRICAL DRAWINGS
6x6 CEDAR #1 POSTS
CEDAR SLATS - SEE
DETAIL __/____
A103
A4
A103
D3
KIOSK, C.F.C.I.
EAVE SHINGLE
DRIP FLASHING
w/ CONT. CLEAT
CONT. 2x4 CEDAR BLOCKING
FLUSH WITH FACE OF
PURLINS. RIP TO 3" HIGH
4x6 CEDAR PURLINS
CENTERED ON POST
8x12 CEDAR #1 BEAM
LIGHT FIXTURE - SEE
ELECTRICAL DRAWINGS
6x6 CEDAR #1 POSTS -
SEE KIOSK PLAN
2x6 T&G CEDAR DECKING
ASPHALT SHINGLES TO MATCH
MAIN BUILDING. OVER FULL-
FIELD ICE & WATER SHIELD
UNDERLAYMENT
1/4"x 4" SCREWS IN "TOE-NAIL"
CONFIGURATION - 2 ON EACH SIDE
6x6 CEDAR #1 POST -
ANCHOR TO FOOTING
AS SHOWN
POST-BASE - 3/8"
THICK BEARING PLATE
w/ 3/16" THICK PLATE BENT TO "U" SHAPE w/
16" EMBEDDED INTO
FOOTING. SECURE TO
POST w/ (3) 1/2" DIA.
307 BOLTS
SLOPE TOP 1-1/2"
CONDUIT WHERE IT OCCURS
1/2" EXPANSION JOINT FILLER
(4) #4 BARS, VERTICAL
#3 TIES AT 8" O.C.
N .T
.S
.5
C L R
1'-6"
4'-10" 4'-2"
/2
/2 "6
9'-0"
/2
Sisters
RANGER STATION
DESCHUTES
National Forest
8"
4"
/2
R-10" @ LOWER
TOP CORNER
3-1/2" THICK CEDAR
SIGN PANEL EACH
SIDE. PAINT TOP
SECTION PS2 AND
BOTTOM SECTION PS3
R=12" @ BOTTOM
CORNERS, TYP.
CARVED 8" HIGH
LETTERS, FONT PER
FOREST SERVICE NF
LOGOTYPE 10, PAINT
PS2
R=7" @ UPPER
TOP CORNER
CARVED 8" HIGH LETTERS, FONT:
ASA SERIES HIGHWAY GOTHIC,
PAINT PS3 @ TOP SECTION AND
PS2 @ BOTTOM SECTION
REUSE EXISTING
MOUNTING POSTS
EXISTING MASONRY
BASE TO REMAIN
PROVIDE ALUMINUM
FOREST SERVICE
SHIELD SIGNS, BOTH
SIDES.
DOUBLE SIDED SIGN
PROVIDE ALUMINUM
ADDRESS SIGN PER
FOREST SERVICE
STANDARD, BOTH
SIDES.
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:4
P M
A103
AS/STSsho
20145.01
S
IT
E D
E T
A
IL
S
SITE DETAILS
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
1/4" = 1'-0"
B2 SITE PLAN - SLIDING GATE
1/4" = 1'-0"
C1 SLIDING GATE OPERATOR ELEVATION
1/4" = 1'-0"
D1 SLIDING GATE OPERATOR SECTION
1/4" = 1'-0"
C2 PEDESTRIAN GATE W/ ACCESS CONTROL
1/4" = 1'-0"
D2 CHAIN LINK FENCE
1/4" = 1'-0"
A3 KIOSK - PLAN
1/4" = 1'-0"
B3 KIOSK - ELEVATION
1/4" = 1'-0"
C3 KIOSK - SECTION
3/4" = 1'-0"
A4 KIOSK - EAVE
1" = 1'-0"
D3 KIOSK POST BASE
1/4" = 1'-0" B4 Agency Sign
N
P A
RK
IN
G
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
WM
WM
W S
WM
W S
T
S
CO
S
CO
S
CO
CO
S
C O
S
S
CO
CO
CO
CO
CO
E L
I RR
NO PARKING
NO PARKING
STORAGE BUILDING
(UNDER SEPARATE
PERMIT)
PRO
PO
SED BUILDING
13,244 SF
S A N
TIA
M H
IG
H W
A Y
N O
R T
H P
IN
E
S T
R E
E T
W. MAIN
STREET
W. ADAMS
STREET
A
B
B
SLIDING GATE #2
SLIDING GATE #1
CHAIN LINK
FENCE DETAIL
'-0
EXISTING BUILDING
NEW BUILDING
NEW FENCE
PROPERTY LINE
ACCESSIBLE PATH TO
PUBLIC R.O.W.
LANDSCAPE AREA
PREVIOUS WORK UNDER
SEPRATE PERMIT
PHASE 2 WORK UNDER
THIS PERMIT - SEE CIVIL
DRAWINGS FOR EXTENT
PHASE 3 WORK UNDER
THIS PERMIT - SEE CIVIL
DRAWINGS FOR EXTENT
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:5
P M
A104
AS/STSdkb
20145.01
S
IT
E S
IG
N
A G
E P
L A
N
SITE SIGNAGE PLAN
09/27/21
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
1" = 50'-0"
D5 SITE PLAN
1 EXISTING FIRE LEVEL CONDITION SIGN TO BE REMOVED AND RELOCATED.
2 EXISTING SMOKEY BEAR SIGN TO BE REMOVED AND RELOCATED.
3 INSTALL EXISTING FIRE LEVEL CONDITION SIGN IN THIS LOCATION.
4 INSTALL EXISTING SMOKEY BEAR SIGN IN THIS LOCATION.
5 REMOVE EXISTING RANGER DISTRICT AGENCY SIGN, PRESERVE EXISTING
MASONRY BASE AND SUPPORT POSTS. INSTALL NEW AGENCY SIGN PER
DETAIL B4/A103.
6 INFORMATION KIOSK, SEE DETAIL A3/A103.
7 INTERPRETIVE AREA INFORMATION SIGNS, 4 TOTAL.
8 'NO SMOKING' SIGN, SEE DETAIL B1/A101
9 ACCESS AISLE SIGNAGE, SEE DETAIL C3&D3/A101
10 VAN ACCESSIBLE PARKING SIGN, D2/A101
11 ABA PARKING SIGNAGE, SEE DETAIL C2/A101
12 STOP SIGN, R1-1
13 SMALL PLANT IDENTIFICATION SIGNS
GENERAL NOTES:
0' 50'25' 150'100'
SCALE : 1" = 50'-0"
n
KEYED NOTES:
A. SEE SHEET A001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. SEE TITLE SHEET FOR DRAWING INDEX.
C. DO NOT SCALE DRAWINGS.
D. REFER TO SHEETS A101, A102 & A103 FOR SITE RELATED DETAILS
E. CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE
CONTRACTING OFFICER ANY ERRORS, INCONSISTENCIES OR OMISSIONS
BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
F. CONTRACTOR SHALL REVIEW AND COMPLY WITH THE REQUIREMENTS OF
CHAPTER 33 OF THE OREGON STRUCTURAL SPECIALTY CODE,
"SAFEGUARDS DURING CONSTRUCTION' PRIOR TO COMMENCING ANY
CONSTRUCTION ACTIVITIES.
G. ALL SIGNAGE UNDER SEPARATE PERMIT
H. REFER TO CIVIL DRAWINGS FOR HORIZONTAL CONTROL INFORMATION,
DRAINAGE, SLAB AND PAVING ELEVATIONS.
I. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION AND SLAB DESIGN.
J. REFER TO ELECTRICAL & LANDSCAPE DRAWINGS FOR ADDITIONAL SITE
INFORMATION.
K. FOLLOW ALL RECOMMENDATIONS AND REQUIREMENTS OF THE
GEOTECHNICAL INVESTIGATION UNLESS MORE STRINGENT
REQUIREMENTS APPEAR IN THE CONTRACT DOCUMENTS AND
SPECIFICATIONS.
L. LIMITS OF WORK: THE CONTRACTOR SHALL CONFINE OPERATIONS AT THE
SITE TO AREAS PERMITTED BY LAW, ORDINANCES, PERMITS AND THE
CONTRACT DOCUMENTS. CONTRACTOR SHALL NOT UNREASONABLY
ENCUMBER THE SITE WITH MATERIALS AND/ OR EQUIPMENT.
M. STAGING AREA: THE CONTRACTOR AND SUBCONTRACTORS SHALL LIMIT
STORAGE OF MATERIALS AND LOCATIONS OF PORTABLE FIELD OFFICES AS
APPROVED BY THE CONTRACTING OFFICER.
N. GENERAL CONTRACTOR SHALL TAKE CARE NOT TO DAMAGE OR DISRUPT
EXISTING UTILITIES WHILE EXCAVATING, GRADING OR DIGGING DURING
CONSTRUCTION. CONFIRM LOCATION OF EXISTING UTILITIES OF ADJACENT
PROPERTIES BEFORE YOU DIG.
K. UNLESS NOTED OTHERWISE, SIDEWALKS AND RAMPS SHALL BE
CONSTRUCTED TO THE FOLLOWING REQUIREMENTS:
a. MAXIMUM CROSS SLOPE OF SIDEWALKS: 1:50
b. MAXIMUM SLOPE OF SIDEWALKS: 1:20
c. MAXIMUM SLOPE OF RAMPS: 1:12
d. MAXIMUM SLOPE OF ACCESIBLE PARKING STALLS 2% IN ANY
DIRECTION
L. PRIOR TO CONTRACTOR REQUESTING A BUILDING DEPARTMENT
FOUNDATION INSPECTION, THE SOILS CONTRACTING OFFICER SHALL
ADVISE THE BUILDING OFFICIAL IN WRITING THAT:
a. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE
SOILS REPORT.
b. THE UTILITY TRENCHES HAVE BEEN BACK FILLED AND COMPACTED.
c. THE FOUNDATION EXCAVATIONS COMPLETE THE INTENT OF THE
SOILS REPORT.
M. PRIOR TO START OF WORK, THE CONTRACTOR SHALL COORDINATE WITH
EACH RESPECTIVE GOVERNING AUTHORITY IN VERIFYING THE LOCATION
(INVERT ELEVATIONS, HORIZONTAL CONTROLS, EASEMENTS) OF EXISTING
SANITARY AND STORM SEWERS, WATER, NATURAL GAS, ELECTRICAL,
FIBER OPTIC, TELEPHONE, OVERHEAD POWER LINES AND UTILITY
SYSTEMS BOTH ONSITE AND OFFSITE. THE CONTRACTOR SHALL
CAREFULLY COMPARE THE DOCUMENTS, NOTIFY THE CONTRACTING
OFFICER IMMEDIATELY IF THE CONTRACTOR BELIEVES THAT A CONFLICT
WILL IMPACT THE CONTRACT PRICE AND/ OR THE CRITICAL PATH OF THE
CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL PROVIDE THE
FOLLOWING:
a. PRELIMINARY ADDITIONAL COST.
b. PRELIMINARY ADDITIONAL CALENDAR DAYS NEEDED.
c. DETERMINE IF A RECOVERY SCHEDULE CAN BE INSTALLED.
N. EMERGENCY VEHICLE ACCESS: THE CONTRACTOR SHALL MAINTAIN FIRE
TRUCK ACCESS TO THE EXISTING BUILDINGS THROUGHOUT THE
CONSTRUCTION PROCESS.
LEGEND:
UP A200B
A200
A200
A200
D5
B
C5
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
A A300
A A300
E A300
E A300
FIRE
READY RM
BREAK RM
DISTRICT
RANGER
OFFICE121
ELEC RM
GENERAL
OFFICE
WOMEN'S
RESTRM.
MEN'S
RESTRM.
JANITOR
FOCUS RM
OFFICE
SM MTG./
OPS ROOM
SMALL
MEETING 102A
STOR
LARGE
MEETING
LOBBY/WAITING
R E
C E
P T
IO
N107
I.T.113
HUDDLE/LAB
LEI OFFICE
PUBLIC
R.R.
PUBLIC
R.R.
GENERAL
OFFICE
HUDDLE
SMALL
MEETING
HUDDLE
RM
GENERAL
OFFICE
CORRIDOR
CORRIDOR
13'-7" 31'-0" 29'-9" 31'-0" 30'-8" 40'-11 3/4" 8'-7 1/4" 15'-0"
200'-7"
RESTROOM
RESTROOM
100A
ENTRY
VESTIBULE
A
F
IR
E R
IS
E
R
B A300
B A300
C A300
C A300
MEZZ ACCESS
HATCH + LADDER -
SEE C2/A540
LINE OF ROOF
ABOVE
C L
R
DISPLAY
WALL
D1 A310
D2 A310
A400
C4
A400
D1
A400
D2
A4101
A410
A414
9 1
ADMIN
OFFICE
134A
VEST.
C
B
K
B B
C C
128A
127A
118A119A
125A
121A 117
102D
134A
107A
105A
104A
D4 A310
D3 A310
D A300
D A300
D1 A311
A412 1
A400
C5
A400
C3
CORRIDOR
COPY /
5'-0"
A414 1
A410 1
K A301
K A301
H A301
/4
/4
/2
/4
A531
A2
A531
B2
CONDENSING UNIT - SEE
MECHANICAL DRAWINGS
K K
D CCDC
K A A
C2 A520
BRACE
@ ROOF
10'-0"
C D CCDC
6L
6L6B
6L
6J 6J
6L
6L
6L
6L 6J
6J
6J
6J
6J
6L 6L
6J
6L
6J
A580
C3
A580
B1
A580
C1
1'-6"
J A301
3'-10" 3'-5" 4'-11"
11'-1 1/4"
6E
6E 6E
A531
C3
A530
B5
A400
D3
A411
CORRIDOR
A413
WEST
VESTIBULE
B
KA
6C
115 111
112 108
C.R.
B
K
K
A
C D D C
L A301
6K
6E
6L
6E
6L
6E
6E 6E
6E
6E
6E 6E
FILE ROOM
/4
A580
A3
F.E.
F .E
F.E.
F .E
15'-8 1/4" 5'-10"
A201A
120124
CLEARSTORY RELITES
A531
A1
OUTSIDE CORNER
@MASONRY VENEER
INSIDE
CORNER
@ SIDING
OUTSIDE
CORNER
@ SIDING
A531
B1
INSIDE
CORNER
@MASONRY
VENEER
A531
C1
18'-2 5/8"
VERIFY
4'-7"
4'-4" 5'-6" 2'-3" 7'-0" 2'-10" 7'-0" 2'-3" 5'-6" 4'-3 3/4"5'-2" 5'-6" 1'-4" 7'-0" 1'-4" 5'-6" 5'-2"5'-2" 5'-6" 1'-4" 7'-0" 1'-4" 5'-6" 5'-2"
40'-11 3/4" 5'-2" 5'-6" 1'-4" 7'-0" 1'-4" 5'-6" 5'-2" 5'-2" 5'-6" 1'-4" 7'-0" 1'-4" 5'-6" 5'-2"
DN
D N
DN
D N 1/8" / 12"
/4
1/8" / 12"
/8
R1 R1 R1 R1R1
FIELD TESTFIELD TEST
F
IE
L D
T E
S T
F
IE
L D
T E
S T
102C
C L R
102B5"
1'-6" MIN.
102A
1/8" / 12"
/8
1/8" / 12"
5'-0"
5'-0"
4'-0 7/8" 6'-0" 6'-0" 6'-0" 6'-0"
E E E E
CD
A1 A201
A2 A201
100100A
IJ
J I
6B
6B
/2
G
H
F
G
G
H
MIN.
1'-6"
2'-4 7/8"
C.J.
OPTION #2
SEE 01 23 00
TYP.
103A
101A103
CLR.
3'-0"
'6
M
IN
'6
M
IN
I H
E T
T C
CRADER
I G
TS
R E
E
SCOTT T. STEELE
G
OOF
ER
A
ET
N O
T S
BEND, OREGON
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
C h a n d le r A v e n u e
S u it e
B E
N D
O
R
.3
.9 w
.s te e le
-a rc h .c o m
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
D
C
B
A
D
C
B
A
5 4 3 2 1
C O
N F
O R
M
C T
O B
E R
/1
/2
:2
:0
P M
A112
AS/STSjm/sho
20145.01
F L O
R
P
L A
N
FLOOR PLAN
07/19/2021
S
IS
T E
R S
O R
E G
O N
U S
F S
S
IS
T E
R S
R A
N G
E R
D
IS
T R
IC
T
A D
M
IN
B L D
G
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16'
1/8" = 1'-0"
1 FLOOR PLAN
n
GENERAL NOTES:
A. SEE SHEET A001 FOR PROJECT GENERAL NOTES.
B. REFER TO CIVIL AND ELECTRICAL SITE PLAN DRAWINGS.
C. REFER TO SECTION 09 91 23 FOR ITEMS TO BE PAINTED, AND FOR ITEMS THAT
ARE NOT TO RECEIVE FIELD APPLIED PAINT FINISHES.
D. ALL INTERIOR WALLS TO BE SATIN GLOSS PAINT OVER LEVEL 4 GYPSUM BOARD
FINISH, UNLESS OTHERWISE NOTED.
E. ALL DOOR FRAMES TO BE PAINTED P2, GLOSS FINISH. SEE FINISH SCHEDULE.
F. REFER TO SHEET A601 DOOR SCHEDULE AND SPECIFICATION SECTION 08 71 00
FOR HARDWARE REQUIREMENTS, COLOR AND FINISH.
G. REFER TO INTERIOR ELEVATION SHEETS FOR EXTENT OF MATERIALS CALLED
OUT FOR EACH WALL ON THE ROOM FINISH SCHEDULE.
H. SEE WALL TYPES ON SHEET A010 FOR TYPICAL WALL, CEILING, & ROOF
CONSTRUCTION ASSEMBLIES. ALL INTERIOR WALLS, BEARING AND NON-
BEARING, ARE FULL HEIGHT TO UNDERSIDE OF STRUCTURE UNLESS NOTED
OTHERWISE.
I. SEE FLOOR PLANS AND BUILDING SECTIONS FOR LOCATION OF DETAILS FOR
TYPICAL FLOOR-TO-FOUNDATION, FLOOR-TO-WALL, WALL-TO-ROOF
ASSEMBLIES AND HEADER, SILL AND SOFFIT CONSTRUCTION.
J. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
K. REFER TO SPECIFICATIONS.
L. CENTER DISSIMILAR FLOOR FINISH JOINTS UNDER CENTER LINE OF DOORS.
M. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING AS
REQUIRED AT ALL WALL MOUNTED LAVATORIES, DRINKING FOUNTAINS,
CASEWORK, MIRRORS, ETC. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS,
MECHANICAL DRAWINGS, AND SPECIFICATION SECTION 06 10 00.
a. CONTRACTING OFFICER AND ARCHITECT WILL INSPECT ALL LOCATIONS
INDICATED, OR REQUIRED, TO HAVE BLOCKING/BACKING INSTALLED
PRIOR TO COVERING FRAMING. NOTIFY CONTRACTING OFFICER AND
ARCHITECT NOT LESS THAN 4 WORKING DAYS PRIOR TO COVERING
FRAMING.
N. SEE SHEET A560 FOR FINISH DETAILS.
O. SEE ROOM FINISH SCHEDULE ON SHEET A621.
P. REFER TO ABA REQUIREMENTS SHEETS G002 & G003 FOR TYPICAL MOUNTING
HEIGHTS OF ACCESSIBLE WALL-MOUNTED ACCESSORIES AND EQUIPMENT.
Q. CONTRACTOR TO VERIFY ALL ABA CLEARANCES.
17 WALL MOUNTED FLAT-SCREEN TELEVISION, SEE ELECTRICAL DRAWINGS AND 11
30 13.
18 METAL LOCKERS. SEE 10 51 00.
19 PREFINISHED DOWNSPOUT W/ INTEGRATED HEAT TAPE. CONNECT TO GUTTER
AND STORM SEWER. SEE PLUMBING AND CIVIL DRAWINGS.
20 RECYCLING CONTAINERS, OF/OI
21 ACCESSIBLE LOCKER ROOM BENCH. SEE 10 51 00.
22 HI-LO DRINKING FOUNTAIN WITH BOTTLE FILLER, SEE MOUNTING HEIGHT
REQUIREMENTS ON C2/G002 - SEE PLUMBING PLAN ON P101.
23 WALL MOUNTED CHANGING TABLE, SEE ACCESSORY SCHEDULE.
24 HAND DRYER, SEE ELECTRICAL DRAWINGS.
25 FIRE RISER, SEE PLUMBING PLAN ON P101.
26 FREE STANDING SAFE, BY CONTRACTING OFFICER.
27 FURNITURE, CONTRACTING OFFICER FURNISHED/CONTRACTING OFFICER
INSTALLED.
28 24" X 30" ACCESS/INSPECTION PANEL TO UNDERSIDE OF STAIR, REF. SPEC
SECTION 08 31 00.
29 PLASTIC LAMINATE COUNTERTOP, SEE FINISH SCHEDULE AND SECTION 06 40 00.
30 CORNER GUARD
1 FOLDING PARTITION. INSTALL TO MANFUFACTURER'S WRITTEN INSTRUCTIONS.
SEE 10 22 39.
2 MOP SINK. SEE PLUMBING PLAN ON P101.
3 BICYCLE RACK. SEE SPEC SECTION 32 33 13. INSTALL TO MANUFACTURER'S
WRITTEN INSTRUCTIONS.
4 SITE BENCH. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. SEE
SPEC SECTION 12 93 13.
5 WALK-OFF GRATING. SEE DETAIL A3/A560 AND SPECIFICATION SECTION 05 50 00.
6 CAST-IN-PLACE SLAB-ON-GRADE, 4" THICK. SLOPE AWAY FROM BUILDING 5%,
MAXIMUM, ALONG ACCESSIBLE PATH OF TRAVEL. SEE CIVIL PLANS ON C20.1.
7 CAST-IN-PLACE SLAB-ON-GRADE, 4" THICK. SLOPE AWAY FROM BUILDING 1-1/2%,
MAXIMUM, AT LANDINGS. SEE CIVIL PLANS ON C20.1.
8 COPY MACHINE, CONTRACTING OFFICER FURNISHED/CONTRACTING OFFICER
INSTALLED.
9 LATERAL FILE CABINETS, CONTRACTING OFFICER FURNISHED/CONTRACTING
OFFICER INSTALLED.
10 6X6 STRUCTURAL POST - SEE STRUCTURAL FOUNDATION PLAN ON S101.
11 10X10 STRUCTURAL POST - SEE STRUCTURAL FOUNDATION PLAN ON S101.
12 PRINTER/PLOTTER MACHINE, CONTRACTING OFFICER FURNISHED/CONTRACTING
OFFICER INSTALLED.
13 MECHANICAL EQUIPMENT, SEE MECHANICAL PLANS ON M201 & M202.
14 ACCESSIBLE RAMP W/ NON-SLIP FINISH AND GUARDRAILS. SEE CIVIL PLANS ON
C20.1.
15 ABA AUTOMATIC DOOR OPENER. SEE 08 71 00.
16 CARD READER - SEE ELECTRICAL/TECHNOLOGY PLAN ON T101.
KEYED NOTES:
n
MAGNETIC
NORTH
PROJECT
NORTH
R. REFER TO FLOOR FINISH PLANS FOR LOCATION OF DETAILS FOR TRANSITIONS
AND THRESHOLDS.
S. ELECTRICAL PANELS, TRANSFORMERS, AIR HANDLING UNITS, AND DUCTWORK
SHOWN FOR CONTRACTOR CONVENIENCE. SEE ELECTRICAL AND MECHANICAL
DRAWINGS FOR SPECIFIC SIZES, CLEARANCES AND LOCATIONS.
T. REFER TO REFLECTED CEILING PLANS FOR CEILING MOUNTED…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .