PWC Strouds Run Directional Boring
Closed State & local contract opportunity Posted
- Solicitation number
- SRC0000041432
- State
- Ohio
- Responses due
Opportunity facts
- Jurisdiction
Opportunity details come from ohiobuys.ohio.gov. Updated .
About this opportunity
The Ohio Department of Natural Resources is requesting bids for directional boring work at Strouds Run State Park in Ashland County, with bids due September 21, 2026 and a mandatory site visit and pre-bid meeting required for all bidders.
The scope is directional boring under an unnamed headwater stream north of Dow Lake at coordinates 39.355, -82.03911. Total boring length is approximately 20 linear feet. The bidder will determine boring depth under the stream in compliance with all federal and state regulations, install a protective sleeve to accommodate a 2-inch PVC water line, install the 2-inch PVC water line within the protective sleeve (materials provided by the property owner), restore the property to preconstruction condition, and obtain all necessary permits while coordinating with Ohio EPA and other applicable state and federal regulators. Access to the site runs through a wooded path that the property owner will clear prior to work.
No contract value, contract term, incumbent contractor, or evaluation criteria are specified in the source material. The Division of Parks and Watercraft at Strouds Run State Park, 11661 State Park Road, Athens, Ohio 45701, is the ordering division.
Opportunity text
The Ohio Department of Natural Resources is requesting bids for: directional boring in Strouds Run State Park Name or Title of the Service or Supply: Strouds Run State Park Directional Boring Ordering Division and address: Division of Parks and Watercraft Strouds Run State Park 11661 State Park Road Athens, OH 45701 Specifications
- Directional bore under an unnamed headwater stream just North of Dow Lake at 39.355, -82.03911.
- Total length of boring is approximately 20 linear feet (LF).
- Boring depth under the stream to be determined by successful bidder and based on all federal and state regulations.
- Install protective sleeve large enough to accommodate a 2 ½" PVC water line.
- Install 2 ½" PVC water line in protective sleeve. (Materials will be provided by property owner).
- Return property to preconstruction condition.
- Obtain all necessary permits and coordinate with Ohio EPA and all other necessary state and federal regulators for work of this nature.
- Access to boring site is through a short, wooded path to the stream.
- Site and path to site will be cleared by property owner.
Mandatory site visit/Pre-bid meeting to be held for all bidders.
Files
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity