Gholson Ground Storage Tank (GST) Coating Project
Closed State & local contract opportunity
- Solicitation number
- RFB2024-056
- State
- Texas
- Responses due
Opportunity facts
- Jurisdictions
- NIGP codes
- 48634 Detergent, Steam And Hot Water Spray Cleaning , Environmentally Certified Product
- 63028 Fire-Retardant And Heat-Resistant Coatings (Not Aluminum Paint)
- 63162 Paint, Rust Preventative, Environmentally Certified Products
- 92967 Painting Services, Road And Heavy Industrial Equipment
- 93684 Towers, Radio/Radar, Etc., Maintenance And Repair (Including Painting)
- 96221 Cleaning Services, Steam And Pressure
Opportunity details come from txsmartbuy.com. Updated .
About this opportunity
The City of Waco, Texas has issued a Request for Bid (RFB) for the Gholson Ground Storage Tank (GST) Coating Project. This project involves the cleaning, surface preparation, and recoating of an existing 5-million-gallon concrete ground storage water tank located in Waco. The scope of work includes all labor, materials, and equipment required to pressure blast clean and apply a full coating system to the tank's exterior surfaces. The contractor will be responsible for containing any dust, debris, or paint overspray that leaves the City's property. A mandatory pre-bid meeting is scheduled for July 11, 2024 and bids are due by August 1, 2024. The City intends to keep the tank in service throughout the project, and the successful bidder must have 3 years of experience with similar concrete tank coating projects.
The City of Waco is committed to providing fair and equal opportunities for all vendors, especially minority and women-owned businesses (MWBE). Bidders are asked to submit MWBE status information with their bids, though this does not determine the contract award. The pricing sheet outlines bid items for mobilization, tank preparation, rust repair, and full tank recoating, as well as a $15,000 contingency allowance. The City has not provided any details on incumbent contractors or the expected award value for this project.
Opportunity text
The City of Waco has issued this solicitation for the cleaning and top coating of an existing, concrete ground storage water tank known as the Gholson Ground Storage Tank (GST).The Gholson GST was built in 2005 and is a concrete structure with a height of approximately 40-feet, a diameter of 146-feet, with a storage volume of approximately 5 million gallons.The dimensions referenced above are accurate to the best of our knowledge and the appurtenances listed do not represent all tank attachments. It will be the Contractors responsibility to verify the accuracy of this information, orientation of appurtenances as well as the presence of any and all attachments which would be subject to the specified maintenance or impact the Contractors ability to perform the required work.The project includes all labor, materials and equipment, and all operations required to clean (pressure blast) and paint the tank exterior surfaces. The tanks will be cleaned and coated on all exterior surfaces as specified herein.The City of Waco intends to keep the tank in service at all times. The Contractor shall not move or disturb telemetry equipment without the permission from the City of Waco Utilities Department.Contractor shall be responsible for any dust, debris and/or paint droplets which leave City property and/or cause damage to neighboring property. Insufficient containment of abrasive debris and/or generation of nuisance dust or paint beyond City property limits is just cause for shutdown of the job until proper protective measures are in place and violations have been remedied. Contractor shall be responsible for the removal and disposal of all debris.