Clinton River Spillway Weir SCADA Implementation
Closed State & local contract opportunity Posted
- Solicitation number
- WWS-2024-001
- State
- Michigan
- Responses due
Opportunity facts
- Jurisdictions
- NIGP codes
- 031 Air Conditioning, Heating, And Ventilating Equipment, Parts And Accessories
- 220 Controlling, Indicating, Measuring, Monitoring, And Recording Instruments And Supplies
- 285 Electrical Equipment And Supplies, Except Cable And Wire
- 939 Equipment Maintenance And Repair Services For Computers, Office, Photographic, Radio And Television Equipment
- UNSPSC codes
- 25173112 GPS Receiver Autonomous Integrity Monitoring
- 25173110 GNSS Wide Area Augmentation System (WAAS)
- 41115516 Decibel (dB) meter
- 41116402 Vibration and condition monitoring system
- 31261506 Thermostat housing
- 40000000 Distribution and Conditioning Systems and Equipment and Components
- 20121924 Downhole camera system
- 25173113 VOR (Doppler) and DVOR/DME systems
- 25173115 Instrument Landing System (ILS)
- 25173117 ILS glide path equipment
Show all 30
- 25173119 Non-directional beacon and associated equipment
- 25173120 Non-Directional Beacon (NDB)
- 25173121 Direction Finder (DF)
- 25173122 Doppler Direction Finder (DF)
- 25173124 Direction finding equipment accessories
- 25173125 VHF marker beacon and associated equipment
- 41111771 LCR meter
- 81102703 Vibration and condition monitoring service
- 39000000 Electrical Systems and Lighting and Components and Accessories and Supplies
- 39100000 Lamps and lightbulbs and lamp components
- 40100000 Heating and ventilation and air circulation
- 25173114 Doppler Very High Frequency Omni Range (DVOR) Complete ground station
- 25173111 VHF DGNSS data link
- 39110000 Lighting Fixtures and Accessories
- 25173109 Differential Global Positioning System (DGPS) Local Area Augmentation System (LAAS)
- 25173116 ILS localizer equipment
- 25173118 Distance Measuring Equipment (DME)
- 25173126 Global Positioning System (GPS)
- 39120000 Electrical equipment and components and supplies
- 39121650 Racking-in/out device with remote control
- Point of contact
-
- Vincent Astorino vincent.astorino@macombgov.org (586) 615-2436
Opportunity details come from bidnetdirect.com. Updated .
About this opportunity
Macomb County Public Works Office is seeking qualified contractors for the Clinton River Spillway Weir SCADA Implementation for Climate Resiliency project, located in Harrison Township, Michigan. The procurement is a Qualification Based Selection (QBS) process with electronic bid submissions originally planned, but later modified to require physical delivery to the Chapaton Pump Station by 2:00 pm on March 14, 2024. The project involves implementing a comprehensive Supervisory Control and Data Acquisition (SCADA) system, which includes installing two stilling wells with level sensors, a new PLC control panel with CompactLogix processor, indoor and outdoor security cameras, LED lighting, an electric unit heater, and modifications to existing pneumatic controls. Bidders will be evaluated using a point-based scoring methodology: 30 points for overall firm experience, 50 points for experience with Macomb County and MCPWO, 10 points for cost, and 10 points for project completion capability. Required submissions include a bid form, bid bond, debarment certification, Iran Linked Business Certification, and a completed Bidders Qualifications form.
The project is funded through an EGLE State High Water Infrastructure Grant and is subject to Davis-Bacon prevailing wage requirements, which may impact contractor eligibility. While no specific set-aside designations for disadvantaged enterprises were explicitly mentioned, contractors must demonstrate technical capability, relevant experience, and financial stability. The existing spillway infrastructure will require integration with the new SCADA system, with specific programming, access control, and camera integration to be performed by the owner (MCPWO). Bidders must comply with federal labor standards provisions and provide detailed documentation of their qualifications. Though a specific budget range was not disclosed, the comprehensive technical requirements and the use of grant funding suggest a significant investment in modernizing the spillway weir control systems to enhance climate resilience. Interested contractors should carefully review the bid documents, particularly Addendum No. 1, which modified the original submission guidelines.
Files
| File | Type | Posted |
|---|---|---|
| 20240224_Bid_Book_Issued_for_Bids.pdf | ||
| 20240222_Plans_Issued_For_Bids.pdf | ||
| 20240306_Addendum_1.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity