Bid_New Breathing Air Compressor System 08. 2024
Closed State & local contract opportunity Posted
- Solicitation number
- PE-76010-NONST-2025-000000014
- State
- Georgia
- Responses due
Opportunity facts
- Jurisdiction
- UNSPSC code
Opportunity details come from ssl.doas.state.ga.us. Updated .
About this opportunity
The City of Americus Fire and Emergency Services is seeking proposals for a new breathing air system to replace the existing system at Americus Fire Station 2. The procurement consists of three modules - a four-stage compressor, a containment fill station, and an air storage system with accessories. The compressor must have a 14 CFM charging rate, 6000 PSI working pressure, driven by a 230V/60Hz/1 phase motor, and include a purification system, carbon monoxide and filter monitor, and sound-insulated cabinet. The containment fill station must have a 2-bay design with adjustable regulator, cascade control, and fill whips. The air storage system must provide a total capacity of 2036 SCF at 6000 PSIG using four 6000 PSI UN/ISO cylinders. Key requirements include shipping, installation, start-up, air analysis, and training. Proposals are due by September 9, 2024 at 12:00 PM, with a deadline for questions on September 4 at 12:00 PM. The City will evaluate responses based on specified criteria outlined in the SCBA System Evaluation Form.
The procurement does not appear to have any set-aside designations or restrictions on the types of organizations that can respond. No incumbent vendors or current contractors are listed, and the RFP does not indicate any existing infrastructure or technology that requires integration. The RFP does not provide a specific award value or budget range, but bidders must submit their proposed pricing as part of the response.
Opportunity text
Module One - (1) Four stage breathing air compressor ¿ 14 CFM charging rate, 6000 PSI working pressure, driven by a 10-hp 230V/60hz/1 phase ODP motor, complete with the following accessories. ¿ Inlet filter with maintenance indicator ¿ Intercoolers and aftercooler ¿ Interstage and final condensate separators ¿ Interstage and final safety relief valves ¿ Discharge check valve and pressure maintaining valve ¿ V-belt drive with guard ¿ Interstage and final air pressure gauges and oil pressure gauge ¿ Hour meter ¿ Power on switch with indicator light and emergency stop button ¿ Auto start/stop air pressure switch and indicator light ¿ High temperature shutdown switch and warning light ¿ Low oil pressure shutdown switch and warning light ¿ Automatic condensate drain system with muffler/reservoir ¿ Magnetic starter and control transformer mounted in a NEMS I enclosure ¿ Purification system (processes 31,000scf @ 6000psig with a 70 degree inlet temperature ¿ prior to cartridge change) ¿ CMM ¿ Electronic carbon monoxide and filter monitor ¿ Sound insulated cabinet with hinged maintenance access doors Module Two ¿ (1) Containment Fill Station with the following accessories. ¿ 2 SCBA certified containment cylinder fill station ¿ 0 to 6000psig adjustable regulator with gauges ¿ Four bank cascade control with bypass ¿ One master SCBA fill valve and gauge ¿ Two fill whips with CGA connections, line valves and bleed valves ¿ Regulated auxiliary outlet circuit (valve and HP Coupler with mate) ¿ One 6000psi hose (compressor to fill station) ¿ Four 6000psi hoses (fill station to storage bottles) Module Three- (1) Air Storage System with the following accessories. ¿ (4) 6000psi UN/ISO cylinders each supplied with a CGA 702 service valve with safety burst disc, CGA 702 nut and nipple assembly with ¼¿ male JIC outlet fitting ¿ System mounted in a free-standing vertical rack ¿ Total storage volume is 2036scf at 6000psig ¿ (4) UN/ISO storage cylinders have a 10 year hydro
Files
| File | Type | Posted |
|---|---|---|
| CITYOFAMER_6_1873638_1.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity