Z2JZ--Pre-solicitation 519-24-200 Replace Boiler Plant Floor Drains and Drain Lines (VA-24-00003944)
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C25723Q1253
- Agency
-
Veterans Integrated Service Network 17
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- West Texas VA Medical Center Big Spring, Texas 79720, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Administration is seeking a Service-Disabled Veteran Owned (SDVOSB) contractor with General Construction Contracting experience to repair and replace floor drains and drain lines in the boiler plant of the West Texas VA Medical Center. The contractor will also be required to locate all underground utilities in the boiler plant and a 5 ft area around it, following the American Society of Civil Engineers (ASCE) Standard Guideline, and produce a drawing showing the location of all utilities and the new drain lines. The project's magnitude is between $100,000.00 and $ 250,000.00.
- Repair and replacement of floor drains and drain lines in the boiler plant.
- Location of all floor drains and drain lines.
- Removal of old floor drains and drain lines and installation of new ones.
- Location of all underground utilities in the boiler plant and a 5 ft area around it.
- Production of a drawing showing the location of all utilities and the new drain lines.
Notice text
Pre-Solicitation Notice
Date Posted:
August 2, 2023
Title:
Repair/replacement of drain and drain lines inside Building
NAICS Code
236220 Commercial and Institutional Building Construction
Description:
The Department of Veterans Administration is seeking qualified Service-Disabled Veteran Owned (SDVOSB) with General Construction Contracting experience for the replacement of floor drains and lines in the boiler plant located at the West Texas VA Medical Center 300 Veterans Blvd. Big Spring, TX 79720.
The proposed project will restore free flowing floor drains and drain lines to the boiler plant (building two). The contractor is to locate all floor drains and drain lines, remove, and replace them. Removal shall consist of saw cutting the concrete slab chipping out the floor drains, drain lines and replacing them with new floor drains and drain lines. Once installed the drain lines shall be checked for leaks and incased back in concrete.
The VA request that all underground utilities be in the 6,600 square feet boiler plant and also a 5 ft area around the outside of the boiler plant as well. This area calculates out to 2,000 square feet. The Contractor will locate all utilities in accordance with the American Society of Civil Engineers (ASCE) Standard Guideline for the Collection and Depiction of Existing Subsurface Utility Data CI/ASCE 38-02. The horizontal position of existing subsurface utilities shall be located using Quality Level B data is obtained through the application of appropriate surface geophysical equipment and is reproducible with such equipment at any point of its depiction. This information is surveyed to applicable tolerances and reduced onto plan documents. The VA request that a drawing be produced and submitted to the VA that shows the location of all underground utilities in the areas surveyed and the addition of the new drain lines as well.
The work effort, however, does suggest a general, phased sequence of construction:
Location of all floor drains & drain lines.
Replacement of the floor drains and drain lines.
Clean up and approval of work.
Work shall include architectural, plumbing, and all such systems and components as may be necessary to correct the floor drains and drain lines. The North American Industrial Classification System (NAICS) code for this procurement is 236220, General Construction.
This is not a request for offers or proposals. The Government is not obligated to and will not pay for information received as a result of this announcement. Requests for a solicitation will not receive a response.
Per FAR 36.204 the magnitude of this project is between $100,000.00 and $ 250,000.00.
The solicitation for this project will be posted when this notice ends.
Files
| File | Type | Posted |
|---|---|---|
| 36C25723Q1253.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2JZ--Pre-solicitation 519-24-200 Replace Boiler Plant Floor Drains and Drain Lines (VA-24-00003944) | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--598-22-115 Site Utility Infrastructure-NLR | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity