About this opportunity
The Department of Veterans Affairs (VA) Veterans Health Administration (VHA) is seeking a contractor to correct water intrusion issues at Building 8 of the VA Northern Indiana Healthcare System Marion Campus. The project scope includes installing waterproof coving, excavating, backfilling, repairing/replacing roads, sidewalks, drainage, landscaping, and pavement markings. The work also involves waterproofing the existing Building 8 foundation, installing drain tile, a new storm sewer catch basin, and repaving the parking lot. The contract has a 365-calendar day period of performance and requires compliance with VA safety, infection control, and security protocols, including OSHA certifications and VA badging. Bids are due by December 11, 2024 at 1:00 PM EST.
This contract opportunity is a 100% set-aside for service-disabled veteran-owned small businesses (SDVOSBs). The magnitude of construction is between $500,000 and $1,000,000, with a NAICS code of 237110 (Water and Sewer Line and Related Structures Construction). There is no incumbent contractor information provided. The solicitation number is 36C25024B0068 and the project is titled "Z2DZ--Correct Water Intrusion, Building 8 610-22-214 - (FY25)".
Notice text
2 versions
Update #2 · Latest ·
VA NORTHERN INDIANA HEALTHCARE SYSTEM MARION CAMPUS PROJECT: 610-22-214 Correct Water Intrusion, Building 8 SCOPE OF WORK: The contractor will provide all labor, equipment, materials, and supervision necessary to install waterproof coving around building 8. This work will include, but not be limited to, excavating, backfilling, repairing/replacing roads, sidewalks, drainage, landscaping, and pavement markings. The Building 8 water intrusion correction shall accommodate the following functions based on the guides, manuals, and planning criteria. Waterproofing the existing Building 8 foundation Installation of drain tile around the perimeter of Building 8. Install storm sewer catch basin and tie into existing storm sewer system Repave parking lot Provide dehumidification controls B. Special items to consider for this project: 1. Field research of conditions of utility systems located under the area of road work All work is to be completed at the VA Northern Indiana Health Care Marion Campus, 1700 E. 38th Street, Marion, IN 46953. Work to be completed within 365 calendar days from notice to proceed. JUSTIFICATION OF WORK: This project is designed to correct the water intrusion at Building 8 at the Marion VA. SAFETY: A. The Contractor shall be thoroughly familiar with all safety rules and regulations. A 30-hour OSHA Competent Person shall be present for all work, and all additional workers shall have a minimum of a 10-hour OSHA Certification. All welders, pipefitters, carpenters, electricians, etc., performing work must present a valid certification for their respectable trade. B. All work associated with this project shall be in compliance with all VA regulations concerning Safety, Infection Control Requirements, Interim Life Safety Measure Requirements, Parking, Personnel Access, and proper removal/safe disposal of construction waste and debris as listed in the specifications and drawings. The Contractor shall abide by all ICRA requirements that are put into place by the VA infection prevention team. The COR shall provide requirements and forms to the Contractor. C. All work will be performed in accordance with ICRA, but it will be the contractor's responsibility to keep the construction areas clean and not damage the existing equipment. If equipment is damaged during the work, the Contractor will be responsible for any required repairs/replacements. SECURITY: A. The contractor, personnel, and subcontractors shall be subject to federal laws, regulations, standards, VA directives, and handbooks regarding information and information system security as delineated in this contract. B. The contractor shall always wear a VAMC badge when they are on VA property. General Contractor s or subcontractor s employees shall not enter the project site without an appropriate badge. Contractor personnel may be subject to inspection of their personal effects when entering or leaving the project site. Before starting work, the General Contractor shall give the COR two weeks notice to provide security arrangements for employee badging. C. Health screenings may be required for those entering VA property, depending on VA directives, federal emergency response, and CDC testing guidelines. Health screening may be used in an attempt to identify a potential health impact that may be transferrable to VA personnel or patients before documentable symptoms. If health screening activities are implemented at the Facility Level, the Contractor, their personnel, and their subcontractors must adhere to all Facility directions and guidelines when they are on VA property. Before starting work, the Contractor shall give three days notice to the COR so that current health screening activities at the VA Facility may be identified and communicated to Contractor personnel before mobilization (i.e., restricted entrances, limited delivery windows, etc.).
Update #1 ·
VA NORTHERN INDIANA HEALTHCARE SYSTEM
MARION CAMPUS
PROJECT: 610-22-214
Correct Water Intrusion, Building 8
SCOPE OF WORK:
The contractor will provide all labor, equipment, materials, and supervision necessary to install waterproof coving around building 8. This work will include, but not be limited to, excavating, backfilling, repairing/replacing roads, sidewalks, drainage, landscaping, and pavement markings.
The Building 8 water intrusion correction shall accommodate the following functions based on the guides, manuals, and planning criteria.
Waterproofing the existing Building 8 foundation
Installation of drain tile around the perimeter of Building 8.
Install storm sewer catch basin and tie into existing storm sewer system
Repave parking lot
Provide dehumidification controls
B. Special items to consider for this project:
1. Field research of conditions of utility systems located under the area of road work
All work is to be completed at the VA Northern Indiana Health Care Marion Campus, 1700 E. 38th Street, Marion, IN 46953.
Work to be completed within 365 calendar days from notice to proceed.
JUSTIFICATION OF WORK:
This project is designed to correct the water intrusion at Building 8 at the Marion VA.
SAFETY:
A. The Contractor shall be thoroughly familiar with all safety rules and regulations. A 30-hour OSHA Competent Person shall be present for all work, and all additional workers shall have a minimum of a 10-hour OSHA Certification. All welders, pipefitters, carpenters, electricians, etc., performing work must present a valid certification for their respectable trade.
B. All work associated with this project shall be in compliance with all VA regulations concerning Safety, Infection Control Requirements, Interim Life Safety Measure Requirements, Parking, Personnel Access, and proper removal/safe disposal of construction waste and debris as listed in the specifications and drawings. The Contractor shall abide by all ICRA requirements that are put into place by the VA infection prevention team. The COR shall provide requirements and forms to the Contractor.
C. All work will be performed in accordance with ICRA, but it will be the contractor's responsibility to keep the construction areas clean and not damage the existing equipment. If equipment is damaged during the work, the Contractor will be responsible for any required repairs/replacements.
SECURITY:
A. The contractor, personnel, and subcontractors shall be subject to federal laws, regulations, standards, VA directives, and handbooks regarding information and information system security as delineated in this contract.
B. The contractor shall always wear a VAMC badge when they are on VA property. General Contractor s or subcontractor s employees shall not enter the project site without an appropriate badge. Contractor personnel may be subject to inspection of their personal effects when entering or leaving the project site. Before starting work, the General Contractor shall give the COR two weeks notice to provide security arrangements for employee badging.
C. Health screenings may be required for those entering VA property, depending on VA directives, federal emergency response, and CDC testing guidelines. Health screening may be used in an attempt to identify a potential health impact that may be transferrable to VA personnel or patients before documentable symptoms. If health screening activities are implemented at the Facility Level, the Contractor, their personnel, and their subcontractors must adhere to all Facility directions and guidelines when they are on VA property. Before starting work, the Contractor shall give three days notice to the COR so that current health screening activities at the VA Facility may be identified and communicated to Contractor personnel before mobilization (i.e., restricted entrances, limited delivery windows, etc.).
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DZ--Correct Water Intrusion, Building 8 - 610-22-214 | Award Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--542-21-113 | Correct FCA Deficiencies – Repair Water Penetration | NCO 4 Construction East (VA-26-00020634) (VA-26-00020634) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ-- 658-23-108 Correct Stormwater Drainage | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| B533--VANIHCS SPS Water Testing (VA-27-00000760) | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity