Z2DA - Repair AC7 Duct Work - 657A4-24-106
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25524R0058
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Poplar Bluff, Missouri 63901, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is seeking a contractor to repair the AC7 duct work at the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The project requires the removal and replacement of all leaking and/or rusted components of the AC7 supply and return duct work in specific mechanical rooms. The work on the supply duct must be conducted on a weekend to limit effects on patient care. The contractor must review any available as-built drawings and specifications, submit field drawings and materials, and conduct a thorough analysis of the newly installed system. Proposals are due by April 9, 2024 and the period of performance is 45 calendar days.
This solicitation is set aside for service-disabled veteran-owned small businesses. The NAICS code is 236220 and the procurement value is between $25,000 and $100,000. Liquidated damages of $1,500 per day will be assessed for delays in completion. The location of performance is the John J. Pershing VA Medical Center in Poplar Bluff, Missouri.
Notice text
This project is to Repair AC7 Duct Work for the John J. Pershing VA Medical Center. The contractor shall remove and replace all leaking and/or rusted components of AC7 supply and return duct work located in mechanical room GD-038, above the ceiling in mechanical room GD-039, and above the ceiling in mechanical room GD-041. The work on the supply duct must be conducted on a weekend in order to limit effects to patient care. Upon replacement of known leaking and/or rusted components to include the supply and return duct work of AC7, the contractor will then conduct thorough analysis of the newly installed system to ensure there are no remaining leaking or rusted components. Contractor shall review any as-built drawings, specifications, and field verifications in conjunction with the performance of this project. Contractor will submit field drawings and materials as required by the specifications for the project.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z2DA--657A4-24-106, Repair AC7 Duct Work | Award Notice | |
| This notice | Solicitation | |
| Z2DA--657A4-24-106, Repair AC7 Duct Work (VA-24-00051447) | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| F108--657A4-21-800 - VPIH Services for Remove and Replace End of Life Heating, Ventilation and Air Conditioning Construction | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| C1AZ--657A4-26-125 Conduct Roof Deck Assessment Building 8 ME FY27 NRM | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--Renovate Space for Patient Care Improvements | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--657-24-111JC Renovate Ambassador Suite & Main Lobby B1 | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| 657-27-107JC, Replace Select Hot Water Heating System | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity