Z1DA--NRM-const 528A8-23-811 renovate for CT A221-A223
Closed Solicitation Posted
This opportunity was awarded. See its 2 award notices in the notice history.
- Solicitation number
- 36C24224B0039
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 2, is seeking bids to renovate the Cooling Tower at the Stratton VA Medical Center in Albany, New York. The project involves replacing the failing roof system on the Chiller Plant, Building 54, which has caused issues with recently installed equipment. Key requirements include submitting a range of construction-related documents and certifications, as well as complying with security, safety, and infection control standards. Bids will be evaluated based solely on price and price-related factors, with the award going to the responsive, responsible bidder whose bid is most advantageous to the government.
This is an unrestricted solicitation with no set-aside designation. The project has an estimated value between $250,000 and $500,000, with a period of performance of 180 calendar days after the notice to proceed. Bidders must be registered in SAM.gov and verified/certified in VetCert. A site visit is scheduled for July 29, 2024, and bids are due by August 19, 2024. The place of performance is the Stratton VA Medical Center in Albany, New York.
Notice text
To replace the Cooling Tower atop the Chiller Plant, Building 54 (Roof Area 62), located at the Stratton VA Medical Center, Albany, New York. The existing roof system is saturated and in such a state of failure, the leaking of this system has caused problems to recently installed equipment that now needs to be replaced. It is now imperative that the roof system be replaced.
Files
| File | Type | Posted |
|---|---|---|
| Submittal Register 528A8-23-811.xlsx | XLSX spreadsheet | |
| FAR 52.225-2 Buy American Certification.docx | DOCX document | |
| 36C24224B0039_1.docx | DOCX document | |
| Renovate CT A221-A223 Drawings.pdf | ||
| Wage Determination.pdf | ||
| 528A8-23-811 - Bid Specifications.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--528A8-23-811 renovate for CT A221-A223 | Award Notice | |
| Z1DA-- project name: renovate utilities building 13 632-24-1-2419-0001 project no. 632-23-109 | Award Notice | |
| This notice | Solicitation | |
| Z1DA--NRM-const 528A8-23-811 renovate for CT A221-A223 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--528A8-22-814 Consolidate Primary Care Reception | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Building 13 Stair and Roof Replacement at Castle Point VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity