Z1DA--528A8-22-815 replace chiller plant roof system
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24222B0056
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks to replace the roof system atop the Cooling Tower at Building 54 on the Stratton VA Medical Center campus in Albany, New York. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is procuring the removal of the existing saturated roof and installation of a new roof. Offerors must complete all work within 180 calendar days of receiving the notice to proceed and provide a two-year warranty. Responses are due by August 15, 2022.
This is a 100% set-aside for Service-Disabled Veteran Owned Small Businesses. The work involves NAICS 237310 and PSC S206 with an estimated value between $250,000-$500,000 to be performed entirely at the Stratton VA Medical Center located in Albany, New York. The solicitation number is 36C24222B0056 and seeks to address operational problems caused by leaks in the existing chiller plant roof system for Building 54.
Notice text
2 versions
Update #2 · Latest ·
Request For Information (RFI)
Samuel S. Stratton VA Medical Center
Project Name: Replace Chiller Plant Roof System
Project #: 528A8-22-841
Solicitation#: 36C24222B0056
August 02, 2022
RFI #1
Question #1. Please confirm that the elevation of the new roofing system will be equal to the existing elevation. This is an important question because if the new roofing is higher, we will have to remove metal and add wood blocking at the leading edge and penetrations. A change in height will also cause a lot of rebuilding at the newly installed uni-strut pipe supports.
Answer: Existing elevation shall remain, no new additional blocking will be required
Question #2. Please confirm that no additional blocking, support, etc. is required underneath the (1) existing pipe supports, (2) ladders, (3) other devices. If something is required, please detail what that is for each condition.
Answer: No new additional blocking will be required
Question #3. Please confirm the existing edge metal is to remain in place (no work). The scope of work does not describe the metal being removed, reinstalled or replaced in any way.
Answer: Existing metal flashing to be reused
Question #4. Please provide the requirements for re-certification of the existing portable safety rail system.
Answer: Certification will be accomplished via final inspection by the VA COR
Question #5. Is the contractor required to have a SSHO or QCM on site during construction, or can the Superintendent act as all three roles?
Answer: The Superintendent can act as all three
Update #1 ·
To replace the Cooling Tower atop the Chiller Plant, Building 54 (Roof Area 62), located at the Stratton VA Medical Center, Albany, New York. The existing roof system is saturated and in such a state of failure, the leaking of this system has caused problems to recently installed equipment that now needs to be replaced. It is now imperative that the roof system be replaced.
Files
| File | Type | Posted |
|---|---|---|
| 36C24222B0056 0001.docx | DOCX document | |
| (P07) Wage Determination_DBA_05202022.txt | TXT text file | |
| 07 01 50 19 Preparation for Re-Roofing.docx | DOCX document | |
| 07 71 00 Roof Specialties.docx | DOCX document | |
| 07 51 13 13 Built-Up Asphalt Roofing Cold Applied.docx | DOCX document | |
| AF-101 - ROOF ARCHITECTURAL PLAN_Drawing.pdf | ||
| FAR 52.225-2 Buy American Certification.pdf | ||
| 36C24222B0056_1.docx | DOCX document | |
| (P09) Final SOW Chiller Plant Roof Replacement 2022_01_Rev1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--528A8-22-815 replace chiller plant roof system | Award Notice | |
| This notice | Solicitation | |
| Z1DA--528A8-22-815 replace chiller plant roof system | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--528A8-22-814 Consolidate Primary Care Reception | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--657-26-102JC FCA Replace Various Roofs on BLDG 1, JC | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Building 13 Stair and Roof Replacement at Castle Point VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--PROJECT 528A5-27-503 A/E Design Replace Flat Roofs Canandaigua VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity