Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C10F20R0091
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
VA North Texas Health Care Systems-Dallas Campus Dallas, TX 75216 USA

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks capabilities statements from firms for a design-bid-build construction contract to construct a new central utility plant at the Dallas VA North Texas Health Care System campus. The scope of work involves upgrading an existing energy center to add a new 1,500-ton chiller, associated equipment and piping. It also removes four existing cooling towers and replaces them with six new pre-packaged stainless steel cooling towers installed on existing and new concrete basins. Responses are required to demonstrate relevant experience and will be evaluated based on design-bid-build and central utility plant experience, as well as the proposed project management approach. Statements are due by July 10, 2020 and limited to five pages.

The opportunity is set aside for certified SDVOSBs. The NAICS code is 238220 for plumbing, heating, and air conditioning contractors. The possible award value ranges from $10,000,000 to $20,000,000. The project duration is scheduled as 426 calendar days from notice to proceed.

Notice text

Page 5 of 5

Prospective Contractor/Offeror:

This is a Sources Sought Notice and is a preliminary notice for the RFP (Request for Proposal) for a Design-Bid-Build Construction Contract for the Central Utility Plant (CUP) at the Dallas VA, North Texas Health Care System.

Project Description:

VA has a requirement to construct a CUP at the Dallas Campus of the VA North Texas Health

Care System. Building 70 (Energy Center) and Building 37 (Cooling Towers) work includes but is not

limited to Central Utility Plant Upgrade. Work is to include an additional new 1,500-ton chiller; and

associated related work, equipment and piping within Building 70. Also, to be included are provisions for

underground connections from this equipment to the cooling towers. The Building 70 footprint is to

remain the same as it currently exists. The work includes removal of four existing field erected cooling

towers. It also includes the addition of six new pre-packaged stainless-steel cooling towers and

installing them on existing and extended concrete basins. (There will be three new concrete basins

added.) The work includes the provision of sluice gates to allow them to connect with each other. Also

included is the addition of basin sweepers with centrifugal separators for the new cooling tower cells,

and are other related provisions for pumps, piping, etc. within and near Building 70.

ASBESTOS TESTING Asbestos surveys were conducted for Building 70 (Energy Center) and Building 37

(Cooling Towers), however, inspection of and sample collection from the electrical components [electrical

components specifically for four existing chillers and for four existing cooling towers to be impacted

by activities within the current project] were excluded because the systems were energized during the time that

asbestos surveys were being conducted. All samples collected from previous asbestos survey did not identify the

presence of asbestos-containing materials, therefore no evidence of ACM is presently found. The

CONTRACTOR must have the electrical components for these specific items inspected for the presence of

suspect asbestos-containing materials (ACM) and samples tested after the affected systems have been de-

energized and before the components are disturbed. CONTRACTOR must use proper lock-out tag-out

procedures. Samples must be collected in sufficient quantity and analyzed to assure compliance with the Texas

Asbestos Health Protection Rules and collected by a properly trained individual who is licensed by the Texas

Department of State Health Services as either an Asbestos Inspector or an Asbestos Individual

Consultant.

Sources Sought Notice

The approximate project duration will be 426 calendar days from the Notice to Proceed. The

Project Magnitude is between $10,000,000.00 and $20,000,000.00. The North American Industry

Classification System (NAICS) 238220 (Plumbing, Heating, and Air-Conditioning Contractors),

size standard 16.5M.

This effort is anticipated for solicitation as a 100% SDVOSB set a-side. This source sought notice is for market research purposes in accordance with federal Acquisition Regulation (FAR) Part 10 and is to canvass firms classified under one or more of the following SBA programs: 8 (a), HUB Zone, SDV, WOSB, SDVOSB, and /or VOSB. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this source sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought.

Firms interested in submitting their capabilities for this project must include the following information in the cover letter /introduction: (1) Company name, address, point of contact with phone number and e-mail address; (2) Business size determination, and qualifying small business status/certification of Small Business (3) Bonding capacity (from surety). If submitting as a Joint Venture (JV), all JV s must have an agreement, JV entity DUNS, and CVE certification. All SDVOSB firm submitting must provide their CVE certification with date of expiration.

Please limit responses to (5) pages. The Contractor capability statement shall include, but not limited to:

Design-Bid-Build Experience:

Provide at least three projects demonstrating previous experience performing this type of construction (before mentioned) with a value of at least $10,000,000.00.

Design-Bid-Build Experience:

Provide at least three in the past five years that demonstrate Energy Buildings and or/ Cooling Towers (Central Utility Plant upgrade) experience with Hospital, Medical Clinic, Healthcare facility construction experience; if not hospital or healthcare facility experiences provide at least three projects of institutional or administration buildings.

Capability to perform:

Briefly state how this project will be managed.

Respondents are requested to submit capability Statements that exhibit clear and convincing evidence of your firm s capabilities and experience to perform the stated project. Please submit capability packages via email to: Deontrinese Dalton at Deontrinese.Dalton@va.gov no later than 1:00pm CST on July 10, 2020, and in the subject line state CUP Dallas and [Company Name] . All information concerning this requirement will be posted only on the Contract Opportunities website (https://www.BETA.SAM.gov). At this time no solicitation exists, therefore, DO NOT REQUEST A SOLICITATION package.

All future notices related to this procurement will be posted on the Contract Opportunities website (https://www.beta.sam.gov)

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Files

File Type Posted
36C10F20R0091.docx DOCX document

Notice history

Notice Type Posted
Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E Award Award Notice
Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E Latest solicitation Solicitation
Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E Special Notice
Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
CON | Z1DA | replace or chillers | 580-23-105 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement Department Of Veterans Affairs VA North Texas Health Care System Dallas TX 75216 · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Y1DZ--replace chilled water pump at the boiler plant Department of Veterans Affairs Network Contracting Office 2 Bronx, New York 10468, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
CON | Z2DA | replace chiller 1 B104 | 580-24-111 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business

On GovTribe