About this opportunity
This pre-solicitation notice seeks capabilities statements from firms for a design-bid-build construction contract to construct a new central utility plant at the Dallas VA North Texas Health Care System campus. The scope of work involves upgrading an existing energy center to add a new 1,500-ton chiller, associated equipment and piping. It also removes four existing cooling towers and replaces them with six new pre-packaged stainless steel cooling towers installed on existing and new concrete basins. Responses are required to demonstrate relevant experience and will be evaluated based on design-bid-build and central utility plant experience, as well as the proposed project management approach. Statements are due by July 10, 2020 and limited to five pages.
The opportunity is set aside for certified SDVOSBs. The NAICS code is 238220 for plumbing, heating, and air conditioning contractors. The possible award value ranges from $10,000,000 to $20,000,000. The project duration is scheduled as 426 calendar days from notice to proceed.
Notice text
Page 5 of 5
Prospective Contractor/Offeror:
This is a Sources Sought Notice and is a preliminary notice for the RFP (Request for Proposal) for a Design-Bid-Build Construction Contract for the Central Utility Plant (CUP) at the Dallas VA, North Texas Health Care System.
Project Description:
VA has a requirement to construct a CUP at the Dallas Campus of the VA North Texas Health
Care System. Building 70 (Energy Center) and Building 37 (Cooling Towers) work includes but is not
limited to Central Utility Plant Upgrade. Work is to include an additional new 1,500-ton chiller; and
associated related work, equipment and piping within Building 70. Also, to be included are provisions for
underground connections from this equipment to the cooling towers. The Building 70 footprint is to
remain the same as it currently exists. The work includes removal of four existing field erected cooling
towers. It also includes the addition of six new pre-packaged stainless-steel cooling towers and
installing them on existing and extended concrete basins. (There will be three new concrete basins
added.) The work includes the provision of sluice gates to allow them to connect with each other. Also
included is the addition of basin sweepers with centrifugal separators for the new cooling tower cells,
and are other related provisions for pumps, piping, etc. within and near Building 70.
ASBESTOS TESTING Asbestos surveys were conducted for Building 70 (Energy Center) and Building 37
(Cooling Towers), however, inspection of and sample collection from the electrical components [electrical
components specifically for four existing chillers and for four existing cooling towers to be impacted
by activities within the current project] were excluded because the systems were energized during the time that
asbestos surveys were being conducted. All samples collected from previous asbestos survey did not identify the
presence of asbestos-containing materials, therefore no evidence of ACM is presently found. The
CONTRACTOR must have the electrical components for these specific items inspected for the presence of
suspect asbestos-containing materials (ACM) and samples tested after the affected systems have been de-
energized and before the components are disturbed. CONTRACTOR must use proper lock-out tag-out
procedures. Samples must be collected in sufficient quantity and analyzed to assure compliance with the Texas
Asbestos Health Protection Rules and collected by a properly trained individual who is licensed by the Texas
Department of State Health Services as either an Asbestos Inspector or an Asbestos Individual
Consultant.
Sources Sought Notice
The approximate project duration will be 426 calendar days from the Notice to Proceed. The
Project Magnitude is between $10,000,000.00 and $20,000,000.00. The North American Industry
Classification System (NAICS) 238220 (Plumbing, Heating, and Air-Conditioning Contractors),
size standard 16.5M.
This effort is anticipated for solicitation as a 100% SDVOSB set a-side. This source sought notice is for market research purposes in accordance with federal Acquisition Regulation (FAR) Part 10 and is to canvass firms classified under one or more of the following SBA programs: 8 (a), HUB Zone, SDV, WOSB, SDVOSB, and /or VOSB. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this source sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought.
Firms interested in submitting their capabilities for this project must include the following information in the cover letter /introduction: (1) Company name, address, point of contact with phone number and e-mail address; (2) Business size determination, and qualifying small business status/certification of Small Business (3) Bonding capacity (from surety). If submitting as a Joint Venture (JV), all JV s must have an agreement, JV entity DUNS, and CVE certification. All SDVOSB firm submitting must provide their CVE certification with date of expiration.
Please limit responses to (5) pages. The Contractor capability statement shall include, but not limited to:
Design-Bid-Build Experience:
Provide at least three projects demonstrating previous experience performing this type of construction (before mentioned) with a value of at least $10,000,000.00.
Design-Bid-Build Experience:
Provide at least three in the past five years that demonstrate Energy Buildings and or/ Cooling Towers (Central Utility Plant upgrade) experience with Hospital, Medical Clinic, Healthcare facility construction experience; if not hospital or healthcare facility experiences provide at least three projects of institutional or administration buildings.
Capability to perform:
Briefly state how this project will be managed.
Respondents are requested to submit capability Statements that exhibit clear and convincing evidence of your firm s capabilities and experience to perform the stated project. Please submit capability packages via email to: Deontrinese Dalton at Deontrinese.Dalton@va.gov no later than 1:00pm CST on July 10, 2020, and in the subject line state CUP Dallas and [Company Name] . All information concerning this requirement will be posted only on the Contract Opportunities website (https://www.BETA.SAM.gov). At this time no solicitation exists, therefore, DO NOT REQUEST A SOLICITATION package.
All future notices related to this procurement will be posted on the Contract Opportunities website (https://www.beta.sam.gov)
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Files
| File | Type | Posted |
|---|---|---|
| 36C10F20R0091.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E | Award Notice | |
| Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E | Solicitation | |
| Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E | Special Notice | |
| Y1NB--Central Utility Plant (CUP) Construction-VA Dallas 549-820E | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z2DA | replace chiller 1 B104 | 580-24-111 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity