Y1DZ--Replace Grease Duct Canteen 610A4-25-504
Closed Solicitation Posted
- Solicitation number
- 36C25025Q0453
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking a contractor to replace a grease duct and exhaust fan in the canteen area of Building 1 at the VA Northern Indiana Health Care System in Fort Wayne. The solicitation (Number 36C25025Q0453) requires a comprehensive renovation of the existing kitchen ventilation system, including demolition of current ductwork, fabrication and installation of a new 16-gauge duct with fully welded seams, and replacement of the end-of-life exhaust fan. Contractors must provide all labor, materials, equipment, and supervision to complete the work, with the project to be conducted over a weekend to minimize operational disruption. The site visit is scheduled for May 9, 2025, with bid submissions due by May 27, 2025, at 10:00 EDT. Evaluation will likely include contractor safety records, technical capabilities, and compliance with detailed specifications for commercial kitchen hood and ventilation systems.
The solicitation is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with an estimated project value of less than $25,000. The project has a 90-day performance period from the Notice to Proceed, with strict requirements for maintaining grease hood operability throughout the renovation. Contractors must submit detailed safety documentation, including OSHA 300 Forms from 2020-2022, and demonstrate compliance with subcontracting limitations (no more than 50% of contract value can be paid to non-certified firms). The work will be performed at 2121 Lake Ave in Fort Wayne, Indiana, with specific technical requirements including UL-listed grease extractor filters, demand ventilator control systems, and adherence to NSF certification standards. Contractors will need to provide comprehensive documentation of their safety performance, insurance modification rates, and ability to meet the VA's rigorous technical specifications for kitchen ventilation systems.
Notice text
4 versions
Update #4 · Latest ·
Left blank
Update #3 ·
Questions and Answers:
Unable to assess exhaust fan electrical requirement on site visit. We are requesting electrical and CFM specs for existing fan.
If awarded, would it be possible to leave a boom lift onsite for an additional week to accommodate any potential repairs or adjustments?
Yes, you can leave the boom lift onsite an additional week if needed.
Existing Exhaust Fan: M#PNU165J1231 / Spec Sheet Attached.
Update #2 ·
RFI Questions and Responses
Can you tell us who the hood manufacturer and model is?
I am not seeing a manufacturer name or model on the hood itself. This will have to be something that is look at during the pre-bid site walk.
Update #1 ·
Intentionally left blank
Files
| File | Type | Posted |
|---|---|---|
| 36C25025Q0453 0003.docx | DOCX document | |
| Canteen fan.pdf | ||
| Pre Bid Sign In Sheet.pdf | ||
| 36C25025Q0453 0002.docx | DOCX document | |
| 36C25025Q0453 0001.docx | DOCX document | |
| Attachment II - RFI Template.doc | DOC document | |
| Attachment IV - VHA Directive 1192-01.pdf | ||
| Attachment VI - Drawing 2.pdf | ||
| Attachment I - Wage Determination.pdf | ||
| Attachment VIII - Specifications.pdf | ||
| Attachment VII - Drawing 1.pdf | ||
| Attachment V - VA Notice of Limitations on Subcontracting.docx | DOCX document | |
| Attachment III - EMR.docx | DOCX document | |
| 36C25025Q0453_1.docx | DOCX document |
Show all 14
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Y1DZ--Replace Grease Duct Canteen 610A4-25-504 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Vent Hood Services | Air Combat Command | Total Small Business | |
| PN: 438-21-403, Renovate First Floor Kitchen (SF) | Veterans Integrated Service Network 23 | Service-Disabled Veteran-Owned Small Business | |
| H941--Chemical Hoods & HEPA PM | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity