Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems

Closed Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
668-21-100_0004
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
WA 99205

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20 seeks upgrade of Air Handling Units 18, 20, and 22 and associated mechanical systems at Mann-Grandstaff VA Medical Center in Spokane, Washington, with proposals due June 8. This is a Service-Disabled Veteran-Owned Small Business set-aside. Amendment 0004, effective May 18, addresses Requests for Information and adds technical specifications; offerors must acknowledge receipt of the amendment prior to submission.

Place of performance is Spokane, WA 99205. The NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors; PSC is Y1DA, Construction of Hospitals and Infirmaries.

Staffing requires three separate individuals on-site at all times—a Site Safety and Health Officer, Quality Control manager, and Superintendent—with no dual-role assignments. Working hours are 0700–1600 during normal station operations, with coordination required for noise-sensitive areas near inpatient care. The VA will coordinate all user relocations; contractors manage only furnishings movement within work areas. Phases will be turned over in sections due to limited facility space.

Fireproofing specifications mandate spray-applied mineral fiber or cementitious coverings compliant with ASTM E1042 Class (a), Category A, with asbestos-prohibited materials. Installers must be manufacturer-certified with minimum three years' experience and four prior installations. Field testing by a COR-approved independent laboratory is required at one sample per 929 square meters of floor area or two per floor, whichever is greater. Contractors must identify and coordinate disconnection and reconnection of low voltage devices per sheet A201; VA staff maintain these systems. Current system maintenance contractors are Fire Systems West (fire alarm) and Control Solutions North West (HVAC DDC). A layover yard is provided without temporary power. Asbestos abatement quantities must be determined by the contractor based on the provided environmental sampling report.

Notice text

Amendment 0004 to address RFIs.

Files

File Type Posted
Attachment 11 RFI Questions.docx DOCX document
36C26026R0044 0004.docx DOCX document
Attachment 12 Specs Section 078100.pdf PDF

Notice history

Show all 12

Similar open opportunities

Opportunity Agency Set-aside Responses due
Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center Spokane, Washington 99205, United States · NAICS 238220 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business
Z2DA--Copy of FY27Q1-CON 668-24-106 Renovate CLC East Wing and Courtyard NAICS 236220 Veterans Integrated Service Network 20 No set-aside
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System NAICS 238220 Veterans Integrated Service Network 20 No set-aside
Y1DA--561-24-600 Upgrade Mechanical Systems-C Level Department of Veterans Affairs New Jersey VA Health Care System East Orange, New Jersey 07018, United States · NAICS 238220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Y1DA--NRM-CONST 528-CSI-102 Urology Equipment Site Prep | FY27 NRM Buffalo, New York 14215, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors