Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems
Closed Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 668-21-100_0004
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- WA 99205
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20 seeks upgrade of Air Handling Units 18, 20, and 22 and associated mechanical systems at Mann-Grandstaff VA Medical Center in Spokane, Washington, with proposals due June 8. This is a Service-Disabled Veteran-Owned Small Business set-aside. Amendment 0004, effective May 18, addresses Requests for Information and adds technical specifications; offerors must acknowledge receipt of the amendment prior to submission.
Place of performance is Spokane, WA 99205. The NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors; PSC is Y1DA, Construction of Hospitals and Infirmaries.
Staffing requires three separate individuals on-site at all times—a Site Safety and Health Officer, Quality Control manager, and Superintendent—with no dual-role assignments. Working hours are 0700–1600 during normal station operations, with coordination required for noise-sensitive areas near inpatient care. The VA will coordinate all user relocations; contractors manage only furnishings movement within work areas. Phases will be turned over in sections due to limited facility space.
Fireproofing specifications mandate spray-applied mineral fiber or cementitious coverings compliant with ASTM E1042 Class (a), Category A, with asbestos-prohibited materials. Installers must be manufacturer-certified with minimum three years' experience and four prior installations. Field testing by a COR-approved independent laboratory is required at one sample per 929 square meters of floor area or two per floor, whichever is greater. Contractors must identify and coordinate disconnection and reconnection of low voltage devices per sheet A201; VA staff maintain these systems. Current system maintenance contractors are Fire Systems West (fire alarm) and Control Solutions North West (HVAC DDC). A layover yard is provided without temporary power. Asbestos abatement quantities must be determined by the contractor based on the provided environmental sampling report.
Notice text
Amendment 0004 to address RFIs.
Files
| File | Type | Posted |
|---|---|---|
| 36C26026R0044 0004.docx | DOCX document | |
| Attachment 11 RFI Questions.docx | DOCX document | |
| Attachment 12 Specs Section 078100.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Y1DA--CON-NRM-668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Award Notice | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| This notice | Solicitation | |
| Amendment 0003 Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Amendment 0002 Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Amendment 0001 Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Pre-Solicitation | |
| Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems | Pre-Solicitation |
Show all 12
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2DA--Copy of FY27Q1-CON 668-24-106 Renovate CLC East Wing and Courtyard | Veterans Integrated Service Network 20 | No set-aside | |
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | No set-aside | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Modernize Damen (Bldg. 1) Elevators Construction 537-24-101 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| H379 Mann-Grandstaff VA Medical Center Kitchen Equipment Regular Maintenance and Repairs | Veterans Integrated Service Network 20 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity