Y1AZ--NRM_const_526-21-521 replace surgical lights
Closed Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C24225B0012
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- New York 10468, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration, through its Veterans Integrated Service Network 2, is seeking a contractor to replace surgical lights in Operating Rooms 4-10 at the James J. Peters DVA Medical Center in Bronx, NY. The project requires comprehensive installation of new STERIS surgical lights, booms, supporting infrastructure, conduits, conductors, junction boxes, and ceiling cameras, with specific technical requirements including compliance with NEC and NFPA codes. Contractors must provide a dedicated supervisor with 7 years of electrical engineering experience and obtain third-party inspection for medical gas systems. Bids will be evaluated based on technical capabilities, compliance with specifications, and ability to perform work with minimal disruption to hospital operations. The solicitation (36C24225B0012) has a mandatory pre-bid site visit scheduled for February 24, 2025, at 7:00 AM EST, with bids due March 25, 2025, at 2:00 PM EST.
The contract is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with an estimated value between $1-2 million under NAICS code 238210 for electrical contractors. The place of performance is Bronx, NY 10468, with a project period of 210 calendar days from Notice to Proceed. Contractors must implement ICRA Level 4 infection control barriers, maintain negative pressure in work areas, and coordinate closely with VA staff to minimize operational disruptions. The project involves extensive technical integration, including installation of VIVOTEK FD9369 cameras and STERIS surgical equipment infrastructure across multiple operating rooms. Davis-Bacon wage rates will apply, with specific minimum wage requirements for various construction trades. Subcontracting will be limited, with contractors required to perform at least 15% of the work with their own workforce.
Notice text
3 versions
Update #3 · Latest ·
This amendment A0002 is for solicitation 36C24225B0012 to Replace Surgical Lights project 526-21-521 at the James J. Peters DVA Medical Center, Bronx, NY.
Note to all bidding contractors: Please disregard previously posted Amendment A0001, as it was not directly linked to the original solicitation. When submitting bids, please enter N/A for Amendment A0001 on SF30. All RFI's will be responsded to with this Amendment A0002. Acknowledgment or lack of acknowledgment for Amendment A0001 will not be a basis for unresponsiveness.
Thank you for your interest in this project.
Sincerely,
Patricia
Update #2 ·
This solicitation 36C24225B0012 is for the Replace Surgical Lights project 526-21-521 at the James J. Peters DVA Medical Center, Bronx, NY.
Update #1 ·
This solicitation 36C24225B0012 is for the Replace Surgical Lights project 526-21-521 at the James J. Peters DVA Medical Center, Bronx, NY.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Y1AZ--NRM_const_526-21-521 replace surgical lights | Solicitation | |
| This notice | Solicitation | |
| Y1AZ--NRM_const_526-21-521 replace surgical lights | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--Brooklyn Upgrade Life Safety/Critical Branch Electrical Distribution Construction | VA Technology Acquisition Center | Total Small Business | |
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Y1DA | 521-24-102 | Renovate Wards 2K and 2B for Optometry/Ophthalmology Clinical Use | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--561-26-104 Repair Operating Room (OR) & Bathroom Leaks | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity