About this opportunity

The Department of Veterans Affairs National Acquisition Center is seeking construction services for HVAC corrections at the Emergency Pharmacy Service (EPS) Warehouse located at the Great Lakes Consolidated Mail Outpatient Pharmacy in Hines, Illinois. The project encompasses comprehensive construction activities including general requirements, existing conditions work, concrete, metals, thermal and moisture protection, openings, finishes, HVAC systems, electrical, and low voltage installations to address temperature, water leakage, and humidity issues in the pharmaceutical staging area. Key work includes installing two new Daikin rooftop units with steam heating coils and replacing stormwater drain pipes in multiple phases while maintaining continuous pharmaceutical operations. The contractor must provide all labor, materials, equipment, construction, installation, commissioning, operation and maintenance manuals, as-built drawings, and permits. Critical deliverables include a Contractor Quality Control Plan, Critical Path Method schedule, comprehensive safety plan, weekly progress reports, and warranty documentation. The response deadline is September 1, 2025, at 4:30 PM Eastern Time.

This project is designated as a 100% set-aside for Service Disabled Veteran-Owned Small Businesses under NAICS code 236220 (Commercial and Institutional Building Construction) with a small business size standard of $45 million. The contract value is estimated between $1,000,000 and $5,000,000, reflecting the magnitude and complexity of the HVAC and infrastructure corrections required. The performance period is 120 calendar days after Notice to Proceed, with work conducted during normal business hours from 7:00 AM to 4:00 PM, Monday through Friday. The project is structured in phases to minimize disruption to ongoing pharmaceutical operations, requiring careful coordination for moving pharmaceutical materials during construction activities. Work will be performed in Building 37NW at the Great Lakes CMOP facility, with the contractor responsible for maintaining security protocols and providing bi-weekly or weekly progress reports depending on construction activities.

Notice text

THIS IS A PRESOLICIATION NOTICE Title: EPS WAREHOUSE HVAC CORRECTIONS

NAICS: 236220 with a Small Business Size of $45 million

Per FAR 36.204 the magnitude of this project is between $1,000,000 and $5,000,000.

This project will be a 100% set-aside for Service Disabled Veteran-Owned Small Business.

PROJECT OVERVIEW 1.1 PURPOSE: The Department of Veterans Affairs (VA) Consolidated Mail Outpatient Pharmacy (CMOP) intends to perform construction at the Emergency Pharmacy Service (EPS) Warehouse. The construction includes general requirements, existing conditions, concrete, metals, thermal and moisture protection, openings, finishes, HVAC, electrical, and low voltage. The contractor shall be responsible for all aspects of the project and each phase shall be subject to VA approval at designated project milestones. This project includes (but not limited to) all labor, materials, supplies, equipment, services, communications, security, operation and maintenance manuals, as built drawings, permits, construction, installation, and commissioning.

1.2 PROJECT ACTIVITIES: The entire activity of the project will follow the following sequence of events: Pre-proposal Site Visit Request for Proposal Submission Award Post Award Kick-off Meeting Notice to Proceed Bonding & Insurance Plans Security, Schedule, Progress Reports (Bi-Weekly or Weekly depending on activities) Permits, If Necessary Demolition, Construction, Installation, Commissioning, and Training Final Inspection and Punch List Acceptance Operations and Maintenance Manuals AutoCAD Drawings (Design, Construction, As Built) Progress Payments Warranty

SCOPE OF WORK 2.1 GENERAL: The Contractor shall provide all necessary services to meet the program objectives and requirements and to provide the required outcome in terms of overall quality, timeliness, and documentation, per Construction Documents & Specifications titled EPS Warehouse HVAC Corrections - FINAL CDs 20250226 and EPS Warehouse HVAC Corrections - FINAL Specifications 20250226 .

The Contractor shall be responsible for obtaining and coordinating the services of all Sub-Contractors performing other services on site and other entities as part of the contract to ensure the expected quality, timely, and documented final product. Location: Building 37NW, 5000 S. 5th Ave, Hines IL. 60141. Normal work hours are 7:00AM to 4:00PM, local time, Monday through Friday except for Federal Holidays. If the Contractor desires to work on Saturday, Sunday, holidays, or outside the project site s normal working hours the contractor must submit a written request for approval to the VA-COR at least seven (7) working days prior to the proposed start of such work. CMOP and EPS as well as Service & Distribution Center (SDC) operations shall not be impacted. If any activities would potentially impact operations, then they must occur on a Saturday or Sunday when CMOP is not work overtime shifts. T The space will be in-use during construction. Space will be made available for the area of work in accordance with the phasing plan.

2.2 DESCRIPTION OF WORK The EPS Warehouse stores pharmaceuticals and needs HVAC and storm drain system corrections to maintain a reliable environment.

2.3 DELIVERABLES Period of Performance: 120 Calendar days after Notice to Proceed. Dependent on HVAC lead times. Performance and Payment bonds: Due 10 Calendar days after award Proof of Insurance: Due 10 Calendar days after award Contractor Quality Control Plan (CQCP): The contractor shall develop a quality control plan and shall furnish to VA for review no later than 30 calendar days after the receipt of notice to proceed. The plan shall identify personnel, procedures, control, instructions, tests, records, and forms to be used. VA will consider an interim plan for the first 45 calendar days of operation. Installation will be allowed to begin only after acceptance of the CQCP or acceptance of an interim plan applicable to the particular feature of the work to be started. Work outside of the features of the work included in an accepted interim plan will not be permitted to begin until acceptance of a CQCP or another interim plan containing the additional features of the work to be started. After acceptance of the CQCP, the Contractor shall notify the Contracting Officer s Representative (COR) in writing of any proposed change. Proposed changes are subject to acceptance by the Contracting Officer. Schedule: The Contractor shall develop a Critical Path Method (CPM) plan and schedule demonstrating fulfillment of the contract requirements (Project Schedule) and shall keep the Project Schedule current in accordance with the requirements of this section and shall utilize the plan for scheduling, coordinating and monitoring work under this contract (including all activities of subcontractors, equipment vendors and suppliers). See the Specifications for details. Safety Plan: Comprehensive safety plan, AKA the Accident Prevention Plan or Construction Safety & Health Plan, shall be implemented by the Contractor in accordance with the Specifications prior to mobilization. The plan shall be site and job specific, and address all prime and subcontractor work operations. Work cannot proceed without an accepted Safety Plan. The Plan can include Fire Safety rather than having a separate Fire Safety Plan. See the Specifications for details. Progress Reports: Shall be submitted electronically every week to the COR and address, at a minimum, the status of deliverables, project schedule, price and technical performance as they relate to the planned and actual work performed during the past week, work planned for the following two weeks and address any open critical issues. Progress Meetings: Will be held weekly or bi-weekly depending on project status, and 30 minutes to 1 hour in length. The Contractor is responsible for scheduling the meetings, providing the agenda, and documenting minutes. The frequency and duration may change depending on the work activities occurring. Permits: The building is on federally owned property. If any permitting or outside approval is required for delivery and installation of the roof top equipment, like use of a helicopter, the contractor is responsible for obtaining approvals. Operations and Maintenance Manuals (O&M): The Contractor shall provide complete sets of O&M manuals in accordance with the Specifications. Operations and Maintenance Training: The Contractor shall provide on-site O&M training in accordance with the Specifications. O. Warranty Plan: Contractor shall provide a Warranty Management Plan at least thirty (30) days before the planned pre-warranty conference in accordance with the Specifications.

2.4 ACCEPTANCE For the purposes of Warranty and payment for the work performed at a location, government Acceptance will be provided by the VA upon the completion of all the following: The Contractor has demonstrated/verified that the implemented equipment and measures function as intended at commissioning. All punch list items identified during the commissioning have been resolved. The Contractor has provided O&M manuals. The Contractor has provided Record drawings to include a CD with all as-built CAD files, one full set, one half set.

2.5 CONFIDENTIALITY AND NONDISCLOSURE The preliminary and final deliverables and all associated working papers, application source code, and other material deemed relevant by the VA which has been generated by the contractor in the performance of this Order are the exclusive property of the U.S. Government and shall be submitted to the COR at the conclusion of the contract. The Contracting Officer will be the sole authorized official to release verbally or in writing, any data, the draft deliverables, the final deliverables, or any other written or printed materials pertaining to this contract. No information shall be released by the contractor. Any request for information relating to this contract presented to the contractor shall be submitted to the CO for response. Press releases, marketing material or any other printed or electronic documentation related to this project, shall not be publicized without the written approval of the CO. To the extent that the work under this contract requires that the contractor be given access to proprietary business, technical or financial information belonging to the Government or other companies, the contractor shall treat such information as proprietary business sensitive and agrees not to appropriate such information to its own use or to disclose such information to third parties unless specifically authorized by the CO in writing. A mutually agreed to agreement for exchange of sensitive information or nondisclosure agreement may be required.

3. BID ITEMS Base bid by Division without alternates.

Files

Notice history

Notice Type Posted
Y1EZ--765-23-101 EPS Warehouse HVAC Corrections (VA-25-00091960) (VA-26-00042401) Award Award Notice
Y1AZ--765-23-101 EPS Warehouse HVAC Corrections (VA-25-00091960) Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Modernize Damen (Bldg. 1) Elevators Construction 537-24-101 Chicago, Illinois 60612, United States · NAICS 238290 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
CON | Z1DA | replace or chillers | 580-23-105 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
C1DA--578-27-003 - Renovate A Section First Floor of Building 1 - Design FY27 Edward Hines Jr. VA Hospital Hines, Illinois, United States · NAICS 541310 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z1DA--36C25227B0026 Remodel ENT Procedure Rooms CON 537-19-109 Jesse Brown VA Medical Center 820 South Damen Avenue Chicago, Illinois 60612, United States · NAICS 236220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors