X-Ray Computed Tomography (XCT) System

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
1333ND21QNB680016
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Gaithersburg MD 20899 USA

Notice details come from SAM.gov. Updated .

About this opportunity

The National Institute of Standards and Technology seeks to procure an industrial X-ray computed tomography system to support research in measurement uncertainty analysis, additive manufacturing process evaluation, and to provide low-volume calibration services. Offerors must demonstrate that their system meets detailed technical specifications and artifact testing requirements, as quotations will be evaluated based on technical capability, artifact test results, past performance, and price. The deadline for questions is January 12, 2021 and responses are due no later than January 21, 2021.

There is no set-aside designated for this procurement. The NAICS code is 334516 and PSC code is Q200. The single system will be installed and operated at NIST's facilities in Gaithersburg, Maryland. Offerors must include costs for installation, three days of training, a one-year warranty, and transportation and customs fees in their fixed-price quotations.

Notice text

3 versions

Update #3 · Latest ·

AMENDMENT 1 - Please see attached "RFQ Questions" document for answers to questions recieved.  Due date for quotes has also been extended.

THIS IS A COMBINED SYNOPSIS SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART 12.6-STREAMLINED PROCEDURES FOR EVALUATION AND SOLICITATION FOR COMMERCIAL ITEMS-AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTATIONS ARE BEING REQUESTED, AND A SEPARATE WRITTEN SOLICITATION DOCUMENT WILL NOT BE ISSUED. THE SOLICITATION IS BEING ISSUED USING SIMPLIFIED ACQUISITION PROCEDURES FOR CERTAIN COMMERCIAL ITEMS UNDER THE AUTHORITY OF FAR Part 13.

Background: The Dimensional Metrology Group (DMG) and the Production Systems Group (PSG) at NIST require an industrial X-Ray computed tomography (XCT) system to be used for several different research and measurement purposes. The system will be used in the DMG development of error models that predict how different errors in the XCT system, such as geometric misalignments of the components, manifest themselves in XCT measurement results. This would enable NIST to determine a set of test positions for use in performance evaluation standards (ISO 10360 series and ASME B89 series, in particular), which are adequately sensitive to known error sources. For this, NIST requires a system with hardware and software flexibility, especially in access to machine control and the reconstruction process. NIST will use an understanding of the effect of error sources on measurement results along with an error map that NIST generates of the system (using laser interferometry and other tools) to provide estimates of the uncertainty of measurements that are made using the system. This would allow NIST to eventually offer low-volume, specialized, measurement services (calibrations) using the CT system. Subsequently, NIST requires the lowest uncertainties possible. Measurement speed is generally not a concern.

Protection and Encryption of Sensitive Data: To ensure secure, email communications, it is strongly recommended that all prospective offerors obtain email encryption capability. Use of unencrypted email by the submitter is done at the submitter’s own risk but will be accepted by the Contracting Officer. E-mails from the Contracting Officer may, at some point, be limited to prospective offerors with encryption capability.

******************************

Attachments:

  1. Specifications
  2. Instructions to Offerors
  3. Evaluation Criteria
  4. Quotation Checklist
  5. Provisions and Clauses
Update #2 ·

THIS IS A COMBINED SYNOPSIS SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART 12.6-STREAMLINED PROCEDURES FOR EVALUATION AND SOLICITATION FOR COMMERCIAL ITEMS-AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTATIONS ARE BEING REQUESTED, AND A SEPARATE WRITTEN SOLICITATION DOCUMENT WILL NOT BE ISSUED. THE SOLICITATION IS BEING ISSUED USING SIMPLIFIED ACQUISITION PROCEDURES FOR CERTAIN COMMERCIAL ITEMS UNDER THE AUTHORITY OF FAR Part 13.

Background: The Dimensional Metrology Group (DMG) and the Production Systems Group (PSG) at NIST require an industrial X-Ray computed tomography (XCT) system to be used for several different research and measurement purposes. The system will be used in the DMG development of error models that predict how different errors in the XCT system, such as geometric misalignments of the components, manifest themselves in XCT measurement results. This would enable NIST to determine a set of test positions for use in performance evaluation standards (ISO 10360 series and ASME B89 series, in particular), which are adequately sensitive to known error sources. For this, NIST requires a system with hardware and software flexibility, especially in access to machine control and the reconstruction process. NIST will use an understanding of the effect of error sources on measurement results along with an error map that NIST generates of the system (using laser interferometry and other tools) to provide estimates of the uncertainty of measurements that are made using the system. This would allow NIST to eventually offer low-volume, specialized, measurement services (calibrations) using the CT system. Subsequently, NIST requires the lowest uncertainties possible. Measurement speed is generally not a concern.

Protection and Encryption of Sensitive Data: To ensure secure, email communications, it is strongly recommended that all prospective offerors obtain email encryption capability. Use of unencrypted email by the submitter is done at the submitter’s own risk but will be accepted by the Contracting Officer. E-mails from the Contracting Officer may, at some point, be limited to prospective offerors with encryption capability.

******************************

Attachments:

  1. Specifications
  2. Instructions to Offerors
  3. Evaluation Criteria
  4. Quotation Checklist
  5. Provisions and Clauses
Update #1 ·

THIS IS A COMBINED SYNOPSIS SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART 12.6-STREAMLINED PROCEDURES FOR EVALUATION AND SOLICITATION FOR COMMERCIAL ITEMS-AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTATIONS ARE BEING REQUESTED, AND A SEPARATE WRITTEN SOLICITATION DOCUMENT WILL NOT BE ISSUED. THE SOLICITATION IS BEING ISSUED USING SIMPLIFIED ACQUISITION PROCEDURES FOR CERTAIN COMMERCIAL ITEMS UNDER THE AUTHORITY OF FAR Part 13.

Background: The Dimensional Metrology Group (DMG) and the Production Systems Group (PSG) at NIST require an industrial X-Ray computed tomography (XCT) system to be used for several different research and measurement purposes. The system will be used in the DMG development of error models that predict how different errors in the XCT system, such as geometric misalignments of the components, manifest themselves in XCT measurement results. This would enable NIST to determine a set of test positions for use in performance evaluation standards (ISO 10360 series and ASME B89 series, in particular), which are adequately sensitive to known error sources. For this, NIST requires a system with hardware and software flexibility, especially in access to machine control and the reconstruction process. NIST will use an understanding of the effect of error sources on measurement results along with an error map that NIST generates of the system (using laser interferometry and other tools) to provide estimates of the uncertainty of measurements that are made using the system. This would allow NIST to eventually offer low-volume, specialized, measurement services (calibrations) using the CT system. Subsequently, NIST requires the lowest uncertainties possible. Measurement speed is generally not a concern.

Protection and Encryption of Sensitive Data: To ensure secure, email communications, it is strongly recommended that all prospective offerors obtain email encryption capability. Use of unencrypted email by the submitter is done at the submitter’s own risk but will be accepted by the Contracting Officer. E-mails from the Contracting Officer may, at some point, be limited to prospective offerors with encryption capability.

******************************

Attachments:

  1. Specifications
  2. Instructions to Offerors
  3. Evaluation Criteria
  4. Quotation Checklist
  5. Provisions and Clauses
  6. Volume I Subsection A Response Instructions

Files

Notice history

Notice Type Posted
X-Ray Computed Tomography (XCT) System Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
NDI Portable X-Ray Kits Warner Robins, Georgia 31098, United States · NAICS 334419 Air Force Sustainment Center No set-aside
NOVO DR Inc. , Discovery III System 22WNH - Bright XL, and accessories Oak Ridge, Tennessee 37830, United States · NAICS 334517 Department of Energy No set-aside
N6053026PR00924 Industrial 4343HE series 139 micron large format Digital detector NAICS 334517 Naval Air Warfare Center No set-aside