Whiteface Campground Well Replacement
Open Solicitation Posted
- Solicitation number
- 12445527Q0008
- Agency
-
Forest Service
Department of Agriculture
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237110 Water and Sewer Line and Related Structures Construction
- Place of performance
- Makinen, Minnesota 55763, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The USDA Forest Service is soliciting quotations under Total Small Business set-aside RFQ 12445527Q0008 to replace well equipment at Whiteface Campground, with quotes due December 14, 2026 at 1200 hours local time. Eligibility requires an active SAM.gov registration, and quotes must include a completed and signed Schedule of Items, SF-1442 blocks 14-20C, acknowledgment of any amendments, and representations and certifications not already in SAM. Quotes are submitted by email to paul.boucher@usda.gov.
Work is performed at Whiteface Campground in Makinen, Minnesota, within the Superior National Forest's Laurentian Ranger District. Base item 0001 is a lump-sum replacement of Loop 3 well equipment: a 3/4-horsepower submersible pump delivering a minimum of 10 gallons per minute at 240 volts, an Amtrol Well-X-Tol WX-202-UG buried pressure tank precharged at 30-35 psi, an ADA-compliant Woodford S4H frost-proof hydrant, control box, pressure switch from At The Well Controls-Baker Water Systems, pitless adapter, electrical wiring, polyethylene water line, and a well casing extension from approximately 8 inches to 12-18 inches above grade by welding. All piping is polyethylene rated 160 psi per ASTM standards with stainless steel clamps and brass inserts. Hydrostatic testing is required at 1.5 times working pressure or 150 psi, whichever is higher, and water samples must test for Total Coliform at the Forest Service Water Lab in Ely before public use. Work must comply with Minnesota Department of Health Chapter 4725, OSHA standards, and the National Electrical Code. Public access to Loop 3 must be maintained during the May 1 to October 1 operating season, and work is restricted to Monday through Friday, 8 a.m. to 5 p.m., excluding federal holidays.
Work must commence within 14 calendar days of notice to proceed and finish by June 25, 2027. Options include a Loop 3 pitless adapter replacement (0002), Loop 4 full well equipment replacement (1001), and Loop 4 pitless adapter replacement (1002). Quotes must price all items to be responsive.
The NAICS code is 237110, Water and Sewer Line and Related Structures Construction, with a size standard of $45 million. The government estimates construction magnitude at $25,000 to $100,000 for all base and option items combined. If the total award exceeds $35,000, FAR 52.228-13 Alternative Payment Protections apply, with bonding costs included in the quoted price. Davis-Bacon wage determination MN20260098, Buy American provisions, and EO 13706 paid sick leave apply.
Award goes to the lowest-priced responsible quoter whose quote is determined fair, reasonable, and realistic, with one award anticipated. Prices must hold firm for 45 calendar days from receipt.
Notice text
This is a solicitation for commercial construction in accordance with RFO parts 12 and 36.
Solicitation number 12445527Q0008 is issued as a Request for Quotation (RFQ) for the upgrading of well equipment, including: submersible pump, buried pressure tank, frost-free hydrant, control box, pressure switch, pitless adapter, electrical wiring and extending the well casing.
This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 237110 Water and Sewer Line and Related Structures Construction. The small business size standard is $45,000,000.00. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.
Files
| File | Type | Posted |
|---|---|---|
| Att 01_Schedule of Items_261105.docx | DOCX document | |
| Att 03_Wage Rates_260730.pdf | ||
| Sol_12445527Q0008.pdf | ||
| Att 02_SOW and Specs_261026.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| GAOA Grizzly Bear Campground | Region 2 - Rocky Mountain Region | Total Small Business | |
| Electrical Upgrades to the GCAFB/Tanker Base/Fire Cache | Forest Service | Total Small Business | |
| South fork bunkhouse well abandonment project | Forest Service | No set-aside | |
| Ross Springs Waterline Replacement | Forest Service | Total Small Business | |
| Hydrant Repair/Replacement, Midewin National Tallgrass Prairie | Forest Service | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity