W912DY26RA032
Closed Solicitation Posted
- Solicitation number
- W912DY26RA032
- Agency
-
Engineering Support Center Huntsville
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Woman-Owned Small Business
Opportunity facts
- NAICS code
- 541330 Engineering Services
- PSC
- F999 Other Environmental Services
- Place of performance
- 94304
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Corps of Engineers Engineering Support Center Huntsville is procuring pre-demolition survey services for a Veteran's Medical Center facility in Palo Alto, California. The contract requires comprehensive environmental sampling and analysis of Building 54 to identify asbestos-containing materials (ACM), other regulated materials (ORM), lead-based paint (LBP), and polychlorinated biphenyls (PCBs) in paint, with a complete waste stream analysis for RCRA 8 metals. The contractor must plan and execute all sampling activities in accordance with federal, state, and local regulations, complete laboratory testing and analysis within 35 workdays of field sampling completion, and deliver a Pre-Demolition Assessment Report within 15 workdays of receiving sample results. The report must address all accessible areas including the facility exterior, roof, and basement/crawl spaces, and specifically document any areas that were inaccessible during the survey. The solicitation was posted on January 28, 2026, with a proposal due date of February 18, 2026.
This opportunity is designated as a Woman-Owned Small Business set-aside, restricting competition to qualified firms meeting that criterion. The work will be performed at the Veteran's Medical Center facility located in Palo Alto, California (94304). The contract falls under NAICS code 541330 (Engineering Services) and PSC code F999 (Other Environmental Services). No incumbent contractor, award value, or budget range has been specified in this solicitation notice. The comprehensive nature of the sampling requirement and the specific 35-workday and 15-workday timelines indicate a focused, time-sensitive project designed to support the facility reduction planning process.
Notice text
The Veteran?s Administration has tasked the US Army Corps of Engineers Engineering and Support Center, Huntsville to initiate a Facility Reduction requirement at their Veteran?s Medical Center facility in Palo Alto, California. One building is considered excess to the center?s needs. The purpose of this contract is to procure Pre-demolition surveys according to the requirements set forth in this Performance Work Statement (PWS).The objective is to plan and complete the environmental sampling of a facility at the installation. The structure of concern is Building 54. The sampling will determine ACM and ORM materials and complete a Waste Stream Analysis for RCRA 8 metals, lead-based paint (LBP) and PCB?s-in-paint for those parts of the structure currently identified as potentially having any painted components. Following sampling, the Contractor shall be able to completely quantify the environmental contamination present and the methods required to remove and dispose of said contamination in a safe manner. All sampling shall be planned and performed in accordance with Federal, State, and local regulations for the installation. All recommendations for follow-on actions shall also be in accordance with Federal, State, and local regulations. Laboratory testing and analysis shall be completed within 35 workdays following the respective site sampling field activity completion. The results of the site investigation and sampling effort will be provided in an individual Pre-Demolition Assessment Report for the installation that will be submitted within 15 workdays following the receipt of sample results. The intent of this contract effort is to provide comprehensive sampling for all ACM/ORM materials to include the facility exterior, roof, basement/crawl spaces, etc. The Contractor shall make every reasonable effort to access these areas when present in each facility. The Report will specifically address any areas within given structures that were not accessible during the survey and state the size of the area not accessed, and current or immediate previous use of the area not sampled.Refer to the PWS and attached documents for requirement specifics.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| F101--Asbestos Inspection and Semi-Annual Reinspection at the Philadelphia VAMC. | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Environmental Disposal Liabilities Survey | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity