Verson Cell Press TT&E and Repair
Closed Solicitation Posted
- Solicitation number
- FA812521Q0019
- Agency
- Air Force Sustainment Center Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- Tinker Afb Ok 73145 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks test, tear down, evaluation and repair services for an Enprotech Model 60,000 R-50-240 Fluid Cell Press located at Tinker Air Force Base, Oklahoma. The 76th Component Maintenance Squadron at Tinker Air Force Base, on behalf of the Department of the Air Force Materiel Command Air Force Sustainment Center, requires an emergency services contract to address hydraulic oil leaks developing from the north and south ends of the press when pressurized. Proposals will be evaluated on price alone, with award going to the lowest total evaluated price meeting all requirements. Proposals are due by March 5, 2021.
There is no set-aside designation for this requirement. The NAICS code is 811191 and PSC code is J067. The fluid cell press is used in sheet metal manufacturing operations at Tinker Air Force Base. Repairs are required to be completed within one year of award. The place of performance is Tinker Air Force Base, Oklahoma City, Oklahoma. The government estimates this will be a firm-fixed price contract with a total value between $50,000-$150,000 to test, teardown, evaluate, and repair the hydraulic system.
Notice text
76 CMXG/MXDEK requests an Emergency Service contract to Test, Tear Down, Evaluation and repair of Enprotech Model 60,000 R-50-240 Fluid Cell Press SN: 21600, located in the Sheet Metal Organic Manufacturing Shop, 553rd CMMXS. The Fluid Cell Press is used to form end items using hydraulic pressure for a variety of weapon systems and support organizations including KC135, E3, B52, B1, E6, PMXG, AMXG, and CMXG organizations. Hydraulic Oil is seeping out of the North & South ends of the press when the system is pressurizing.
Attachments
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA812521Q00190002 SF 30.pdf | ||
| Verson Cell Press TTE and Repair - Equipment List.pdf | ||
| Addendum FAR 52.212-1 Instructions to Offerors--Commercial Items.pdf | ||
| Verson Cell Press TTE and Repair - Appendix C.pdf | ||
| Addendum FAR 52.212-2 Evaluation--Commercial Items.pdf | ||
| Performance Work Statement .docx | DOCX document | |
| Solicitation - FA812521Q0019.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Verson Cell Press TT&E and Repair | Solicitation | |
| Verson Cell Press TT&E and Repair | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity