USCGC munro NR2 ship service diesel generator

Closed Solicitation Posted

Solicitation number
70Z08526Q0026302
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
336611 Ship Building and Repairing
Place of performance
Kodiak, Alaska 99619, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Coast Guard seeks installation and reprogramming of an Electronic Modular Control Panel (EMCP 3.2) and Electronic Control Module (ECM) on the USCGC Munro's #2 Ship Service Diesel Generator, with proposals due July 1. The procurement is set aside for total small business.

Place of performance is USCG Base Kodiak, Kodiak, Alaska. The contractor must be Caterpillar-certified and supply two specific parts (EMCP part number 4529414 and ECM part number 511 3143) along with all necessary wiring. The contractor shall install and reprogram both modules in the SSDG's local operating panel, test local operation post-installation to confirm proper performance, and deliver a final condition trip report within three days of contract completion. The period of performance runs from July 3 through July 2026. No Government Furnished Equipment is required. The NAICS code is 336611, Ship Building and Repairing; PSC is J020, Maint/Repair/Rebuild Of Equipment—Ship And Marine Equipment. Point of contact is LTJG Igor Guerrero, USCG-SFLC-LRE PL Asset Management, igor.guerrero@uscg.mil, 510-685-0519.

Notice text

STATEMENT OF WORK

CGC MUNRO

NR2 SHIP SERVICE DIESEL GENERATOR

EMCP and ECM INSTALL

Background. Munro has had several issues with the Load Sharing and speed control of the #2 SSDG over the last several weeks. With extensive trouble shooting all results have not corrected the issue. When singled up the generator will not hold the load and cause a “brown out” when in parallel with the other generators trips offline under reverse power relay condition. Ships engineers found Electronic Modular Control Panel (EMCP 3.2) and Electronic Control Module (ECM) faulty which are now obsolete. Cat tech is needed to install both modules and reprogram to stabilize generator.

  1. Scope. Caterpillar certified Tech Rep to provide parts and install EMCP and ECM in the #2 SSDG control panel. MUNRO SSDG serial is NSC 006.  The Tech Rep will be responsible for the following:
  • Providing technical expertise to install all parts and programing in the SSDG’s local operating panel
  • Supply parts and wiring needed for completion
  • Test local operation after install to confirm proper operation of the 1SSDG.
  • Provide a condition Trip report once completed.
  1. GFE: NA
  2. Contractor Furnished Equipment: EMCP part number: 4529414 PANEL GP-ELE, ECM part number 511 3143.
  3. Tasks. The contractor shall provide technical expertise to install EMCP and ECM in the No. 2 SSDG to normal operation.
  1. Delivery. Contractor shall provide a final report within 3 days of contract period of performance.
  1. Place of performance:

CGC MUNRO

Attn: Engineer Officer

USCG Base Kodiak, 5th St, Kodiak Station, AK 99619

  1. Period of performance- 3 July – July 2026
  1. Points of Contact.

10.1. USCG-SFLC-LRE PL Asset Management: LTJG Igor Guerrero, igor.guerrero@uscg.mil 510-685-0519

Files

File Type Posted
SOW EMCP 4.2B Install.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Overhaul of caterpillar marine diesel engine onboard USCG cutters NAICS 336611 — No set-aside
Actuator, governor NAICS 336611 Coast Guard No set-aside
CGC alder auxiliary (raw water) pump San Francisco, California 94130, United States · NAICS 333618 — Total Small Business
MTU engine overhaul parts Curtis Bay, Maryland, United States · NAICS 333618 — Total Small Business
OEM Caterpillar D-398 Engine Overhaul Kit Newport, Rhode Island 02841, United States · NAICS 333618 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity