This is a Statement of Work for the installation and programming of electronic control components on the USCGC Munro's #2 Ship Service Diesel Generator (SSDG). The U.S. Coast Guard is seeking a Caterpillar-certified technical representative to replace faulty and obsolete Electronic Modular Control Panel (EMCP 3.2) and Electronic Control Module (ECM) components that have caused load-sharing and speed control failures on the generator. The contractor must supply two specific parts—EMCP part number 4529414 (PANEL GP-ELE) and ECM part number 511 3143—along with all necessary wiring and provide expert installation and reprogramming services to restore the generator to normal operational status.

The contractor's responsibilities include installing all parts and programming in the SSDG's local operating panel, testing local operation post-installation to confirm proper performance, and delivering a final condition trip report within three days of contract completion. The work will be performed at USCG Base Kodiak in Kodiak, Alaska, with a period of performance from July 3 through July 2026. No Government Furnished Equipment (GFE) is required. The point of contact is LTJG Igor Guerrero at the USCG-SFLC-LRE PL Asset Management office (igor.guerrero@uscg.mil, 510-685-0519).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

CGC MUNRO

NR2 SHIP SERVICE DIESEL GENERATOR

EMCP and ECM INSTALL

Background. Munro has had several issues with the Load Sharing and speed control of the #2 SSDG over the last several weeks. With extensive trouble shooting all results have not corrected the issue. When singled up the generator will not hold the load and cause a “brown out” when in parallel with the other generators trips offline under reverse power relay condition. Ships engineers found Electronic Modular Control Panel (EMCP 3.2) and Electronic Control Module (ECM) faulty which are now obsolete. Cat tech is needed to install both modules and reprogram to stabilize generator.

1. Scope. Caterpillar certified Tech Rep to provide parts and install EMCP and ECM in the #2 SSDG control panel. MUNRO SSDG serial is NSC 006. The Tech Rep will be responsible for the following:

· Providing technical expertise to install all parts and programing in the SSDG’s local operating panel

· Supply parts and wiring needed for completion

· Test local operation after install to confirm proper operation of the 1SSDG.

· Provide a condition Trip report once completed.

2. GFE: NA

3. Contractor Furnished Equipment: EMCP part number: 4529414 PANEL GP-ELE, ECM part number 511 3143.

4. Tasks. The contractor shall provide technical expertise to install EMCP and ECM in the No. 2 SSDG to normal operation.

5. Delivery. Contractor shall provide a final report within 3 days of contract period of performance.

6. Place of performance:

CGC MUNRO

Attn: Engineer Officer USCG Base Kodiak, 5th St, Kodiak Station, AK 99619

7. Period of performance- 3 July – July 2026

8. Points of Contact.

10.1. USCG-SFLC-LRE PL Asset Management: LTJG Igor Guerrero, igor.guerrero@uscg.mil 510-685-0519