USCG Station Sandy Hook HVAC Repair

Closed Solicitation Posted

Solicitation number
SECNY-0962
Agency
Responses due
Set-aside
Local Area Set-Aside

Opportunity facts

Place of performance
Highlands, New Jersey, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Homeland Security US Coast Guard seeks corrective maintenance repairs to two HVAC systems at USCG Station Sandy Hook, with proposals due May 15, 2026. This is a local area set-aside procurement.

Place of performance is 23 Crispin Road, Highlands, New Jersey. The work includes repair of an AAON system (Model CFA-025-C-A-3-DC0EK) and an LG Multi-V system (Model ARUB168DTE4), encompassing replacement of compressors, motors, contactors, inverter boards, filter driers, isolation valves, and related components; evacuation and recharging of refrigerant systems with virgin R410A; acid testing for burnout; and all associated electrical and mechanical work per manufacturer specifications. The Government will furnish certain materials for the AAON system and the compressor for the slave side of the LG system; the contractor must furnish and install remaining components including three refrigerant ball valves, two LG compressors, two inverter boards, and associated accessories. All wages must comply with Service Contract Act prevailing wage rates for the performance area. Work shall be completed within 10 work days from award, conducted Monday through Friday between 0700–1800 hours, with construction to be finished within 3 days unless otherwise directed. Prior to commencing work, the contractor must attend a pre-construction meeting with the Contracting Officer's Technical Representative, submit a progress schedule for approval, and provide daily check-ins. Upon completion, the contractor shall submit a memo documenting recovered and recharged refrigerant amounts. The NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors; the PSC code is J041, Maintenance/Repair/Rebuild of Equipment—Refrigeration, Air Conditioning, and Air Circulating Equipment.

Notice text

To perform corrective maintenance repairs to two HVAC systems, including but not limited to all equipment associated with both AAON & LG Multi V such as compressors, refrigerant lines, Isolation Valves, Motors, etc – among any other issue found on the system upon repairs.
in accorance with the attached Statement Of Work

 all wages MUST be in accorrdance with the SCA, and at the prevailing wage rate for the preformance area and period of preformance.

Files

File Type Posted
FAR CLAUSES - FIXED PRICE SERVICES.docx DOCX document
SECNY0962 - SOW.rtf RTF text file

Similar open opportunities

Opportunity Agency Set-aside Responses due
USCG Station Lake Worth Inlet HVAC Diagnostic and Repairs Riviera Beach, Florida 33404, United States · NAICS 238220 — Total Small Business
Combined Synopsis/Solicitation Notice: Maintenance of Commissary Refrigeration Systems and Repair of Refrigeration, Heating, Ventilation, and Air Conditioning Systems (HVAC) at Hario and Sasebo, Japan Hario Commissary, Building 5127, Sasebo Commissary, Building 1436 and Sasebo Storage Facility, Building 306 Hario and Sasebo Nagasaki Japan · NAICS 811310 ENDIST Japan No set-aside
Rental of AC Unit with Heaters Portsmouth, Virginia, United States · NAICS 532490 Naval Sea Systems Command No set-aside
Compressor unit, REF, in repair/modification of NAICS 333415 Naval Supply Systems Command No set-aside
Gwmp - arho bunker HVAC NAICS 238220 Intermountain Region Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity