USCG Base Cape Cod Backflow repair, replacement and retest
Closed Solicitation Posted
- Solicitation number
- 31125PR260000578
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Massachusetts 02542, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Coast Guard seeks repair, replacement, and retesting of six backflow preventer devices at USCG Base Cape Cod in Buzzards Bay, Massachusetts, with quotes due June 24, 2026. No set-aside applies.
Place of performance is Otis Air National Guard Base, MA 02542. The contractor must provide all personnel, equipment, tools, materials, and supervision necessary to repair and retest one Watts LF009 3-inch domestic device at building 3154 and one Watts 009M2QT 1-inch domestic device at building 3426; repair, replace, and retest one FEBCO 805 4-inch fire device at building 5205, one Ames Colt 400 6-inch fire device at building 3160, one Watts 909 6-inch fire device at building 3170, and one Watts 009M2QTRP 2-inch domestic device at building 5203.
Both the on-site working supervisor and technician must hold valid Massachusetts Backflow Prevention Device Tester Certificates from the Department of Environmental Protection. Personnel must obtain Coast Guard Security Identification cards following background security checks and work during regular government hours (7:00 a.m. to 3:30 p.m., Monday through Friday) unless authorized otherwise by the Contracting Officer. The contractor must submit a safety plan within 15 calendar days of award, a work schedule 15 days before work commences, qualification statements, certificates of insurance, base access forms, and closeout documentation within 7 calendar days of completion.
The NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors; PSC is J045. Wage Determination No. 2015-4045, Revision 35 (effective May 13, 2026) applies, establishing prevailing wage rates and fringe benefits for Barnstable County, Massachusetts. FAR 52.222-90 (DEI discrimination compliance) is incorporated. The Contracting Officer Representative is Jim Pulsifer (Albert.J.Pulsifer@uscg.mil, 571-607-4150). Quotes must be submitted on company letterhead.
Notice text
Provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to repair, replace & retest 6 backflow preventer at USCG Base Cape Cod (BCC) facilities. These facilities are located on Base Cape Cod in Buzzards Bay, MA.
Please read the SOW that is also attached for full details and COR information.
COR Information Jim Pulsifer Email: Albert.J.Pulsifer@uscg.mil 571-607-4150
- Quotes must be submitted on company letterhead.
Files
| File | Type | Posted |
|---|---|---|
| Wage Rates.pdf | ||
| SOW Backflow Preventer Repair and Retest.docx | DOCX document | |
| 52.222-90 Addressing DEI Discrimination by Federal Contractors.docx | DOCX document |