Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 1333ND26QNB680282
- Agency
-
National Institute of Standards and Technology
Department of Commerce
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- Place of performance
- Gaithersburg, Maryland 20899, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The National Institute of Standards and Technology seeks three high-precision rotation stages with supporting control hardware and software for upgrading a cold neutron imaging interferometer, with quotations due June 23, 2026. This is a 100% small business set-aside under FAR Part 12 (commercial products and services).
Place of performance is Gaithersburg, Maryland. The rotation stages must achieve angular position resolution of 0.00001 degrees or better, support a clear aperture of at least 80 mm diameter, weigh under 1 kg, rotate a full 360 degrees, and maintain resolution across beam separations ranging from 1 mm to 300 mm for two gratings and up to 5 meters for a third. The stages must demonstrate zero backlash, powered-off position holding, and rotation speed exceeding 3 degrees per second. The procurement includes three sets of 10-meter cables, motion sensors and control hardware, motion control software (SDK-based in C/C++/C# or .NET), and an optional hand control unit. Delivery is due December 31, 2026. NAICS 334516 (Analytical Laboratory Instrument Manufacturing) with a 1,000-employee small business size standard applies. Pre-quote inquiries are due within 5 calendar days of solicitation issuance. Quotations must remain valid for 90 days from the due date. Offerors must submit three volumes: technical quotation demonstrating compliance with minimum requirements, firm-fixed-price quotation with all costs identified, and terms and conditions acceptance. Award goes to the lowest priced, technically acceptable offeror. No prototypes, demonstration models, used, or refurbished instruments are acceptable. Active SAM.gov registration is required at quotation submission through final payment. Payment is 100% upon installation and acceptance; the Government conducts performance testing within 15 days of receipt, with title transfer upon acceptance.
Notice text
The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.
This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System | Award Notice | |
| This notice | Solicitation | |
| Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity