Upgrade of Air Compressor, Bldg 530 374th Civil Engineer Squadron, Yokota Air Base, Japan
Closed Solicitation Posted
- Solicitation number
- FA520926Q0059
- Agency
-
Pacific Air Forces
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 333912 Air and Gas Compressor Manufacturing
- PSC
- 4310 Compressors And Vacuum Pumps
- Place of performance
- Tokyo Japan
Notice details come from SAM.gov. Updated .
About this opportunity
Pacific Air Forces seeks purchase and installation of one stationary air compressor (BAUER breathing air purification system with SECURUS or equal) and two mobile air compressors (DDTR25 or equal) at Building 530, Yokota Air Base, Japan, with proposals due July 31, 2026. The Government reserves the right to cancel this solicitation before or after the closing date, and no award will be made until funds are available; offerors will not be reimbursed for costs if the solicitation is cancelled.
Place of performance is Tokyo, Japan. The stationary unit is rated for 6,000 PSI with 25.2 SCFM charging rate, measures 101" x 38" x 78", weighs 4,350–4,550 lbs, and features a sound-attenuating enclosure, programmable logic controller with 7-inch color touchscreen, four ASME code-stamped air cylinders, three-phase 200–220V 50/60 Hz power, NEMA 4 rated electrical enclosure with UL-listed control panel, and comprehensive safety shutdowns. Each mobile unit measures 200" x 90" x 105", weighs 8,400 lbs, operates on three-phase 200–220V 50/60 Hz power with diesel/electric dual drive, and includes hydraulic surge brakes, two ASME air storage cylinders, telescoping light mast with four 500-watt fixtures and 7,500-watt auxiliary generator, and four-bank dual function cascade controls. The contractor must deliver both units, perform operational testing and product orientation for the mobile unit, and remove existing equipment with installation of the new stationary unit. Delivery is required within 180 calendar days from award. NAICS code is 333912 (Air and Gas Compressor Manufacturing); PSC is 4310. Award is Firm Fixed Price to the lowest priced offeror meeting specifications.
Notice text
Notice to Offeror(s)/Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs.
Purchase and Install 1 Lot of Stationary Air Compressor (BAUER breathing air purification system with SECURUS or equal) and 2 Lot of Mobile Air Compressor (DDTR25 or equal) , Bldg 530 at Yokota Air Base, Japan.
Files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA520926Q0059.pdf | ||
| Atc_1_Salient Characteristics - AC Bldg 530.pdf | ||
| Procedures for Business w U.S. Government.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Upgrade of Air Compressor, Bldg 530 374th Civil Engineer Squadron, Yokota Air Base, Japan | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Breathing Air Systems Services for Fire Emergency Services at EAFB and P42 | Air Force Test Center | No set-aside | |
| Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan. | Pacific Air Forces | No set-aside | |
| Compressor AY-feed | Construction and Equipment | No set-aside | |
| Compressor unit, recip | Land and Maritime | No set-aside | |
| FY26 ZNRE224305P3 Improve Military Family Housing PAIP 9 Phase 3, Yokota Air Base, Japan | ENDIST Japan | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity