Universal Hydraulic Pump and Motor Test System

Award Notice Posted

Solicitation number
W911KF18Q0039
Agency
Awarded
to James A. Staley Co., Inc.
Set-aside
Total Small Business

Opportunity facts

Contract number
W911KF18C0013 Federal contract award
PSC
Not on record
Place of performance
Anniston Army Depot Anniston, Alabama 36201, United States

Notice details come from SAM.gov. Updated .

Notice text

5 versions

Update #5 · Latest ·

Awarded Vendors: James A. Staley Company. Contract Award Dollar Amount: $786,094.00. Contract Award Date: 2018-06-29.

Update #4 ·

The purpose of this Amendment is:
1. To answ er vendor's questions about the solicitation.
2. To make revisions to ATTACHMENT 1 Statement of Work, specifically paragraph 13.2 Test Requirements, Motor. (Sections 2d, 3.2, 3.4.1,
3.7, 3.8, 3.9 & 3.10)
All other terms and conditions remain unchanged..

Update #3 ·

The purpose of this Amendment is:
1. To answ er vendor's questions about the solicitation.
2. To make revisions to ATTACHMENT 1 Statement of Work, specifically paragraph 13.2 Test Requirements, Motor. (Sections 2d, 3.2, 3.4.1,
3.7, 3.8, 3.9 & 3.10)
All other terms and conditions remain unchanged.

Update #2 ·

This specification establishes the requirements for a Universal Hydraulic Pump and Motor Test System to be located in building 117 at Anniston Army Depot, Anniston Alabama designed, fabricated, and installed by the contractor with all functions and capabilities as delineated herein. The contractor shall provide the resources necessary to design, manufacture, transport, install, site cleanup, calibrate, demonstrate the functional operation, provide training of Anniston Army Depot (ANAD) operator, Calibration, and Maintenance personnel, and documentation of a Hydraulic Pump and Motor Test System (from here on referred to as the test system). Upon installation at ANAD, the test system shall be fully capable of meeting all requirements of this specification. The test system will be used to performance test hydraulic pumps and motors utilizing fire resistant hydraulic oil per MIL-PRF-46170. The test system fabrication, installation, acceptance, and training of Government personnel must be complete within 365 calendar days of award of contract. This specification describes the minimum anticipated operational and performance requirements..

Update #1 ·

This specification establishes the requirements for a Universal Hydraulic Pump and Motor Test System to be located in building 117 at Anniston Army Depot, Anniston Alabama designed, fabricated, and installed by the contractor with all functions and capabilities as delineated herein. The contractor shall provide the resources necessary to design, manufacture, transport, install, site cleanup, calibrate, demonstrate the functional operation, provide training of Anniston Army Depot (ANAD) operator, Calibration, and Maintenance personnel, and documentation of a Hydraulic Pump and Motor Test System (from here on referred to as the test system). Upon installation at ANAD, the test system shall be fully capable of meeting all requirements of this specification. The test system will be used to performance test hydraulic pumps and motors utilizing fire resistant hydraulic oil per MIL-PRF-46170. The test system fabrication, installation, acceptance, and training of Government personnel must be complete within 365 calendar days of award of contract. This specification describes the minimum anticipated operational and performance requirements.

Files

Show all 14

Notice history

Notice Type Posted
This notice Latest Award Notice
Synopsis_Universal Hydraulic Pump and Motor Test System Original Award Notice

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity