Two (2) Agilent Gas Chromatograph with mass selective detector systems

Closed Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
75F40126Q00339
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Cincinnati, Ohio, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Food and Drug Administration seeks two Agilent Gas Chromatograph with Mass Selective Detector (GC/MSD) systems including auto-injector and updated mass spectral libraries, with quotes due August 21, 2026, at 2:00 PM ET. This is not a set-aside procurement.

Place of performance is Cincinnati, Ohio, at the National Forensic Chemistry Center. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing, with a small business size standard of 1,000 employees; PSC is 6640, Laboratory Equipment and Supplies.

Each system must include a capillary gas chromatograph with mass selective detector, auto-sampler capable of holding 150 vials or greater, and updated mass spectral libraries (Wiley23 with NIST23 or latest) with comprehensive data system software including AMDIS program. Minimum performance requirements include GC oven temperature range from 4°C above ambient to 450°C with ramp capabilities up to 120°C/minute; mass spectrometer detector capable of synchronous SIM/full scan operation with analysis up to 1,090 Daltons and electronic scan rate up to 20,000 Daltons/second. Systems must be delivered within 90 days of contract award. Warranty must cover all non-consumable items with unlimited site service visits (maximum 72-hour on-site response time) and one year of phone assistance and analyst familiarization at installation.

Award will be made on a Lowest Price Technically Acceptable basis, with technical acceptability determined on a pass/fail basis against salient characteristics and minimum requirements. Offerors must submit technical quotations, price quotations, warranty terms, UEI with SAM.gov registration confirmation, lead time for delivery, and country of origin for all items. Quotes must be submitted via email to Jennifer.mun@fda.hhs.gov. Solicitation number is 75F40126Q00339.

Notice text

The Government requires two (2) Agilent gas chromatograph/mass selective detector (GC/MSD) systems including auto-injector, and updated mass spectral libraries. The required GC/MSD systems shall conform to the requirements in the Statement of Work listed in teh Combination Synopsis-Solicitation.

Files

File Type Posted
Combo Synopsis Solicitation 0814.docx DOCX document

Notice history

Notice Type Posted
Two (2) Thermo Scientific Heratherm Environmental Incubation Chamber Latest solicitation Solicitation
This notice Original Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors NAICS 221310 EPA Region 4 No set-aside
Sources Sought for (ICP-OES) Spectrometer System with an Autosampler Annapolis, Maryland 21402, United States · NAICS 334516 Naval Supply Systems Command No set-aside
Hidex 600SLe Liquid Scintillation Counter United States · NAICS 334516 National Institute on Drug Abuse No set-aside
Detector, Gas NAICS 334511 Land and Maritime Total Small Business
RFI Only***Sources Sought for Gerstel Thermal Desorption System and Instal US Environmental Protection Agency Ann Arbor, Michigan 48105, United States · NAICS 334516 National Vehicle and Fuel Emissions Laboratory No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity