Synopsis of Fire Extinguisher Maintenance Navy Region Southeast

Closed Pre-Solicitation Posted

Solicitation number
N6883524Q0159presolsynopsis
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Jacksonville, Florida 32212, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Navy Naval Supply Systems Command is seeking proposals for the maintenance, repair, and refilling of HALOTRON fire extinguishers at five Navy installations in Florida, Texas, and Mississippi. The contract requires compliance with NFPA standards and manufacturer specifications, including six-year internal maintenance, hydrostatic testing, and replacement of parts as needed. Contractors must provide a draft plan of actions and milestones with their proposal. Additional chemical and hose/gauge replacement is only allowed on an as-needed basis. The period of performance ends on August 30, 2025.

This contract opportunity is set aside for small businesses. The estimated value is not provided. The work is classified under NAICS code 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, and PSC code J042 - Maintenance/Repair/Rebuild of Equipment - Fire Fighting/Rescue/Safety Equipment; Environmental Protection Equipment/Materials. No potential incumbents or current contractors are named.

Notice text

maintenance, repairs, part replacement for HALOTRON fire extinguishers below, in accordance with National Fire Protection Association (NFPA) Standards. Six year internal maintenance and hydrostatic testing with chemical removal and refill for the 65 LBS (4A:80BC) HALOTRON Cylinders All work shall be performed at the installations: Naval Station Mayport, FL; Naval Air Station Pensacola, FL; Naval Air Station Meridien, MS; Naval Air Station Corpus Christi, TX; and Naval Air Station Kingsville, TX.  Contractor shall comply with Federal, State and local laws, rules, and regulations that will ensure their serviceability and prevent deterioration in value or effectiveness. The Contractor shall provide a draft plan of actions and milestones (POA&M) with its proposal for Government review. Additional Chemical shall only be added as needed to “top off” cylinders or to refill the cylinder in the event there has been damage of some kind to the cylinder *AS-NEEDED ONLY Hose and Gauge Replacement Service for Wheeled Units shall only be required after discharge or failure. *AS NEEDED ONLY Corrective maintenance to be performed to the units and services required are in line with the scope of the contract.

Files

File Type Posted
1.05 PWS SSN.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Fire extinguisher inspection, maintenance, recharge, repair, hydrostatic testing Camp Douglas, Wisconsin 54618, United States · NAICS 811310 Army National Guard No set-aside
Maintenance of Fire Suppression System for HAZMAT lockers (Yokosuka Naval Base) Yokosuka Kanagawa Japan · NAICS 811310 Naval Supply Systems Command No set-aside
36C26127Q0086, Fire Extinguisher Inspection and Maintenance Services San Francisco, California, United States · NAICS 811310 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
Firefighting protection system maintenance Alameda, California 94501, United States · NAICS 336611 — No set-aside
Extinguisher, fire NAICS 339999 Construction and Equipment Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors