Supply of FCU
Closed Solicitation Posted
Not the latest version. See the latest special notice from .
- Solicitation number
- 191N6524Q0126
- Agency
-
Department of State
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Place of performance
- New Delhi Delhi 11002 India
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Department of State is seeking to procure 110 floor/ceiling-mounted 2 TR Fan Coil Units (FCUs) with specific technical requirements, including power supply, airflow, cooling coils, and control features. The contract will be awarded on a firm-fixed price basis to the responsible offeror submitting the lowest acceptable price. Quotations are due by 1400 hrs. (India Time) on August 16, 2024, and offerors must be registered in the SAM (System for Award Management) database prior to submitting their quotation. The solicitation outlines the required documents to be submitted, including the SF-1449 form, pricing information, representations and certifications, and proof of SAM registration.
This solicitation is unrestricted, with no set-aside designations. The place of performance is New Delhi, India, and the FCUs are required to be serviced at the U.S. Embassy in New Delhi. The government has not provided any information regarding potential incumbents or current contractors, and the award value or budget range has not been specified. The quantity of goods required is 110 FCU units, and the delivery is required within 60 days of award.
Notice text
2 TR FCU , make Trane with following specifications 110 ea.
Type-Floor/ ceiling mounted.
Capacity- 2 TR FCU.
Power supply -Single Phase 220-volt Ac/ 50 hz.
CFM-600/800 cfm
Inlet/ outlet size- Inlet/outlet size 7/8 inch.
Mode- Dual mode heat/cool with codeless remote control.
Copper cooling coil/ Fins type- Copper coils and Aluminum fins.
Four-way pipe system- Suitable with Four - way pipe system.
Motorized control valve -In-built 3-way, 220 VAC/50 Hz, 3/8-inch motorized control valve.
Number of motor -1 each.
Fan Speed- 3 each.
Filters- washable ABS type.
Dimensions H627 x W1324 x D234
Working Temperature- Heat and cool temperature setting shall be on 28 Deg C.
Preferably with field reversible coils
Serviced at New Delhi, India
Files
| File | Type | Posted |
|---|---|---|
| SF-1449_191N6524Q0126.pdf | ||
| Solicitation_191N6524Q0126.pdf | ||
| Cover letter_191N6524Q0126.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Supply of FCU | Special Notice | |
| Supply of FCU | Special Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| FPC bryan, TX - replace HVAC system ICC building | Federal Correctional Institution Beckley | Total Small Business | |
| FCI mckean camp admin air handling unit & installation | Federal Correctional Institution Mckean | Total Small Business | |
| Cooler unit, air | Construction and Equipment | No set-aside | |
| Compressor Units and Spares | Naval Sea Systems Command | No set-aside | |
| Air conditioner | Construction and Equipment | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity