Sole Source: Iradimed 3880 Non-Magnetic Patient Monitor System
Open Special Notice Posted
- Solicitation number
- HT941026N0012
- Agency
-
Defense Health Agency
Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Hawaii 96859, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Defense Health Agency Contracting Activity (DHACA), Healthcare Contracting Division-SD, issued a Special Notice of intent to sole-source the Iradimed 3880 Non-Magnetic Patient Monitor System to IradiMed Corporation, with vendor responses due 10:00 a.m. Pacific Daylight Time on Monday, November 30, 2026. The Set Aside line reads "No Set-Aside Used," but the sole-source intent is the controlling constraint, and vendors may challenge the determination by submitting capability statements.
The requirement supports safe physiological monitoring of patients undergoing MRI procedures. The Government states that the Iradimed 3880 is the only FDA-cleared non-magnetic patient monitor designed for 3 Tesla MRI environments up to 30,000 gauss and that IradiMed is its sole manufacturer and distributor. The procurement covers one MRI Standard Monitor System (3880Q-4), one MRI Monitor Remote System with tablet and recorder (3885), one Roll Stand (1119M), one Flexible Mounting Adapter (1891), two-day training (8700), and a monitor trade-in discount (9997M). Delivery is required within 90 days after receipt of order to Tripler Army Medical Center, 1 Jarrett White Road, Tripler AMC, HI 96859-5000.
Challenging vendors must submit capability statements of no more than six pages (8.5 x 11 inches, 10-point minimum font) demonstrating the ability to provide the MRI Standard Monitor System with ECG, SpO2, NIBP, CO2, and temperature monitoring. Submissions go to Contract Specialist Kenneth Harmon (kenneth.d.harmon.civ@health.mil) or Contracting Officer Cha-on P. Gordon (cha-on.p.gordon2.civ@health.mil).
Notice text
See attached Notice of Intent to Sole Source HT941026N0012 for Iradimed 3880 Non-Magnetic Patient Monitor System to support safe physiological monitoring of patients undergoing magnetic resonance imaging (MRI) procedures.
Files
| File | Type | Posted |
|---|---|---|
| Notice of Intent to Sole Source HT941026N0012.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| OEM Draeger Equipment Maintenance, Repair, and Calibration Services - Naval Hospital Camp Pendleton | Defense Health Agency | No set-aside | |
| 6515--midas drills | Veterans Integrated Service Network 6 | No set-aside | |
| Notice Of Intent to Sole Source Vantive PRISMAX & THERMAX Service | Defense Health Agency | No set-aside | |
| Nordson Medical Quest MPS 3 | Defense Health Agency | No set-aside | |
| J065--Fort Harrison GE Precision Radiology Preventive Maintenance | Veterans Integrated Service Network 19 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities