Smith Septic System (Squaxin Island)
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 75H70124Q000
- Agency
- Indian Health Service Department of Health and Human Services
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237110 Water and Sewer Line and Related Structures Construction
- PSC
- Y1NZ Construction Of Other Utilities
- Place of performance
- Shelton, Washington 98584, United States
- Points of contact
-
- Robert S. Miller robert.miller2@ihs.gov (214) 767-8589
- Andrew E. Hart andrew.hart@ihs.gov (206) 375-4443
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Health and Human Services Indian Health Service is seeking to procure the installation of an individual septic system with a subsurface drip system drainfield on fee land in Mason County, Washington. The proposed septic system consists of solid sewer pipe, an underground cleanout, an aerobic treatment unit, a pump chamber, pump and controls, supply and return lines, manifolds, and a 684 square foot subsurface drip system drainfield. The contractor will be responsible for obtaining any required permits, including the Department of Ecology Notice of Intent/Washington Water Resources Department. Quotes are due by September 16, 2024 at 2:00pm CST.
This solicitation is being issued as a 100% Small Business Set Aside under NAICS code 237110, with an estimated construction magnitude between $25,000 and $100,000. The period of performance is 45 calendar days from issuance of the Notice to Proceed. The place of performance is Shelton, WA 98584. There are no incumbent contractors or specific budget ranges mentioned in the available documentation.
Notice text
This project is for the installation of an individual septic system with a subsurface drip system drainfield on fee land in Mason County, WA. The proposed septic system is to consist of solid sewer pipe, an underground cleanout, an aerobic treatment unit rated for 500 gallons/day, a 1,000-gallon pump chamber, pump, and controls, 80 feet of supply and return line, manifolds, and 684 square feet of subsurface drip system drainfield containing approximately 456 feet of drip line. Any permits, including the Department of Ecology Notice of Intent/Washington Water Resources Department (WWRD), are the responsibility of the contractor.
Attachments
| File | Type | Posted |
|---|---|---|
| 6-US DOL Wage Determination WA20240053 Dated 5-24-2024.pdf | ||
| 5-Septic Design.pdf | ||
| 2-Measurement and Payment.pdf | ||
| B01 75H70124Q00041 Rev.pdf | ||
| A11 Pre-Solicitation SAM notice DRAFT.pdf | ||
| 1-Statement of Work.pdf | ||
| 4-Aerial View.pdf | ||
| 3-Technical Specifications.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Smith Septic System (Squaxin Island) | Award Notice | |
| Smith Septic System (Squaxin Island) | Solicitation | |
| Smith Septic System (Squaxin Island) | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity