Scanivalve Calibration System

Closed Solicitation Posted

Solicitation number
80NSSC26936068Q
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Cleveland, Ohio 44135, United States

Notice details come from SAM.gov. Updated .

About this opportunity

NASA's Shared Services Center is procuring a Scanivalve SPC4050 2-Channel Pressure Calibrator system on a sole-source basis, with interested parties required to submit written capabilities statements by June 18, 2026 at 7:00 a.m. Central Standard Time. The procurement is conducted under FAR Part 12 procedures for commercial items, with Scanivalve Corporation identified as the sole provider meeting established technical requirements.

Place of performance is NASA Glenn Research Center in Cleveland, Ohio. The system comprises four line items: the SPC4050 pressure calibrator with IS-33 transducers providing 0.008% full-scale accuracy and internal barometer; a Scanivalve SPC4050PLU-2 Pneumatic Logic Unit (2-channel, 90 psi control) for positive and vacuum calibrations; a Scanivalve 70380-02 Pneumatic Distribution Panel (2-channel, 90 psi control); and a Scanivalve 73680 4-Range Portable Calibration System with all components installed in a protective transport case. Channel A includes Low Pressure Servo Regulators calibrated to 5.75 psig and 17 psig; Channel B includes Medium Pressure Servo Regulators calibrated to 56 psig and 115 psig. The system features a color touch screen and removable/interchangeable transducers, designed for automated DSA5002 calibrations in bench or rack-mount configurations. Period of performance is 14 weeks from authorization to proceed. The vendor must provide a one-year warranty against defects in materials and workmanship from original delivery. NAICS code 334513. Submissions will be evaluated to determine competitive feasibility; the government retains sole discretion whether to compete. NASA FAR Supplement Clause 1852.215-84 regarding the Ombudsman applies.

Notice text

** THIS IS A SOLE SOURCE REQUIREMENT ** for Scanivalve Calibration System

Files

File Type Posted
SATPC0041463 Tab 06 RDSS..pdf PDF
SATPC0041463 Tab 07 Capability Statement.pdf PDF
SATPC0041463 Tab 04 4 SOW..pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Flowserve MKII control valve to replace obsolete Fischer control valve on Complex-41 GN2 United States · NAICS 541330 Shared Services Center 8(a) Sole Source
Repair and replacement of existing MTS lab Equipment Hampton, Virginia 23681, United States · NAICS 334519 Shared Services Center No set-aside
CVI Helium Compressor & System Component Rebuilds and Spare Parts Cleveland, Ohio 44135, United States · NAICS 332999 Shared Services Center No set-aside
Flowmeter, calibration, and signal conditioners needed for panel modification for ESR United States · NAICS 541380 Shared Services Center Total Small Business
Eddy Current Array Instrument (Reddy) NAICS 334519 Shared Services Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity