Santa Ana Road Fence Replacement

Awarded Award Notice Posted

Solicitation number
R15PS01233
Agency
Bureau of Reclamation Department of the Interior
Awarded
to Big Wakoo Fence, Inc.
Set-aside
Total Small Business

Opportunity facts

Contract number
INR15PC00099 Federal contract award
NAICS code
238990 All Other Specialty Trade Contractors
PSC
Not on record
Place of performance
Northern portion of the Lake Casitas watershed along North Santa Ana Road and Avenal St Ventura, California 93001, United States

Notice details come from SAM.gov. Updated .

Notice text

Added: Jun 16, 2015 4:47 pm This RFQ is to replace and repair damaged and deteriorated portions of the entire 2.6 miles of fence (see map). Wire will be replaced on the entire 13,915 foot length (2.6 miles) Complete re-construction of the fence is required on 10,031 feet (1.9 miles). An estimated length of 3,884 feet (.74 mile) will require only wire replacement. H-braces are required to be built throughout the entire fenceline including the wire only replacement sections. H-Braces will be installed at every beginning, ending, corner, gate location, high spot, low spot, and at a maximum of 200' - 250' over straight runs. There are a few sections of the fenceline that contain segments where the t-posts and braces are suitable to stay in place. These areas will be identified onsite with the GOTR and the length total to remain in place is represented in the 3,884 foot section of fencing where wire only is required. Lengths of fence and sections of fenceline where H-braces and T-posts are acceptable have been utilized in the estimated totals. Tree limbs and brush that have grown into the fence line will be trimmed back 2' from center line of fence. Trimmed material can be stacked for wildlife use or habitat. Several creeks pass under fence line and these areas will require fence crossings that restrict public and livestock entry, but allow for debris flow during periods of high rain runoff. Corner posts will be required at obvious corner sets, end posts and supports at each of the gate locations. (estimate 5 gates). All of the wire on the entire fenceline will be replaced. The Fence is to be 4-strand, with top wire smooth, 2nd and 3rd line barbed, bottom line smooth. 12.5 gauge, 4 pt.for barbed, 10 gauge galvanized twisted cable for barbless wire. T posts will be 1.33 heavy gauge, 6.5' in length, 4' above ground. Fence line will be cleaned and prepared by a Bobcat Tractor or similar piece of equipment with a small blade attachment and bucket recommended, to make a fence line pad only. Staging of equipment and materials will be inside of fence line. All materials and equipment shall be secured by Contractor after hours.

Attachments

Files attached to this notice, newest first
File Type Posted
R15PS01233_Fence_Replacement-Q A.pdf PDF
Amendment_0002_SF30.pdf PDF
SF-18_R15PS01233.pdf PDF
SF-30 _Amendment_0001.pdf PDF
D-B_Wage_Determination.pdf PDF
SantaAnaRd_OpenSpace_Fencing_SOW_ExhibitC.jpg JPG image
SOW_R15PS01233.pdf PDF
Solicitation_-_R15PS01233.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Santa Ana Road Fence Replacement Latest Award Notice
Santa Ana Road Fence Replacement This notice · Original Award Notice

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities