Replacement of Fire Hydrants, Edinburg, Texas

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
12639522R0009
Agency
Responses due
Set-aside
HUBZone

Opportunity facts

Place of performance
Edinburg, Texas 78541, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks a firm-fixed price construction contract for the replacement of 28 fire hydrants located at Moore Air Base in Edinburg, Texas. The Department of Agriculture Animal and Plant Health Inspection Service seeks to award a contract to a firm that can remove existing hydrants and valves and install new hydrants and valves with isolation gates within 150 days of receiving the notice to proceed. Offerors must meet all material, safety, and licensing standards. Proposals will be evaluated on price, technical capability, and past performance on similar projects, with references and details of relevant experience required. The deadline for proposal submission is January 28, 2022.

This is a HUBZone set-aside solicitation. The primary NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, with an estimated value between $250,000 and $500,000. The place of performance is Edinburg, Texas. Offerors must have the ability to complete the work within the 150-day timeframe and meet all qualifications.

Notice text

6 versions

Update #6 · Latest ·

Solicitation and attachments posted below.

See amendment 0001 below.

See amendment 0002 below.

See amendment 0003 below.

Q's and A's: What is the depth of the main line? 4.5 feet.  Are we replacing every valve shown on the map? Yes.  When replacing the hydrants, are we using ductile iron or are we allowed to use blue pipe? (dr-18 c900) Replace with original pipe material--ductile iron.  It also discusses leaving the ditch open, would we be able to leave a ditch open if we cover it with a steel plate? Yes.  Are there any asphalt, concrete, or sidewalk surrounding the hydrants/bollards? There are no hydrants on concrete or any sidewalk.

Update #5 ·

Solicitation and attachments posted below.

See amendment 0001 below.

See amendment 0002 below.

See amendment 0003 below.

Q's and A's: What is the depth of the main line? 4.5 feet.  Are we replacing every valve shown on the map?  Yes  When replacing the hydrants, are we using ductile iron or are we allowed to use blue pipe? (dr-18 c900)  Replace with original pipe material--ductile iron.  It also discusses leaving the ditch open, would we be able to leave a ditch open if we cover it with a steel plate?  Yes

Update #4 ·

Solicitation and attachments posted below.

See amendment 0001 below.

See amendment 0002 below.

See amendment 0003 below.

Update #3 ·

Solicitation and attachments posted below.

See amendment 0001 below.

See amendment 0002 below.

Update #2 ·

Solicitation and attachments posted below.

See amendment 0001 below.

Update #1 ·

Solicitation and attachments posted below.

Files

File Type Posted
12639522R0009-0003.pdf PDF
12639522R0009-0002.pdf PDF
12639522R0009-0001.pdf PDF
12639522R0009.pdf PDF
Attachment 3.doc DOC document
Attachment 2_map of hydrant locations.pdf PDF
Attachment 1_Fed Constr wage rates_TX20210255.pdf PDF

Notice history

Notice Type Posted
Replacement of Fire Hydrants, Edinburg, Texas Award Award Notice
This notice Latest solicitation Solicitation
Replacement of Fire Hydrants, Edinburg, Texas Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity