About this opportunity

The Federal Bureau of Prisons (FBOP), Federal Correctional Institution (FCI) El Reno is seeking to procure supplies and materials for in-house vacuum condensate system repairs. Specifically, they require a JVC-18-45-255 Skidmore Duplex Vacuum Condensate System, including a 60-gallon steel tank, JV-18 duplex vacuum producer, and a NEMA 1 700 series control panel. All supplies and materials must be submitted with full product detail sheets and specifications. The contract will be awarded on a firm-fixed-price basis, with the offer due by May 30, 2024 at 4:00 PM CT.

This opportunity is set aside for small businesses, and the NAICS code is 238220 with a size standard of 500 employees. The place of performance is FCI El Reno, located in El Reno, OK. Deliveries must be made between 8:00 AM and 2:30 PM, Monday through Friday, excluding federal holidays. The total value of the contract is unknown, but the procurement is for a specific vacuum condensate system to replace the existing unit at the facility.

Notice text

Scope of Work

The Federal Bureau of Prisons (FBOP), Federal Correctional Institution (FCI) El Reno intends to purchase

supplies and material for in-house vacuum condensate system repairs at FCI El Reno, located at 4205 Highway

66 West, El Reno, OK 73036.

All supplies and materials must be submitted with full product detail sheets and specifications.

B. Material and Supplies Requirements FREIGHT INCLUDED

JVC-18-45-255 SKIDMORE DUPLEX VACUUM CONDENSATE SYSTEM COMPLETE WITH THE FOLLOWING:

NOTE: UNIT MUST BE AN EXACT REPLACEMENT FOR S/N 128382

(1) 60 Gallon Steel Hurling Tank

(1) JV-18 Duplex Vacuum Producer 200/3/60 - 3500 RPM - ODP Rated18 CFM @ 5 1/2" HG

(1) 3/8" Solenoid Make Up Valve Strainer

(1) Reverse Acting Float Switch

(1) Temperature Limiting Switch

(1) Gauge Glass Assembly

(2) Vacuum Switches

(1) 45 Gallon Rectangular CI RCV

(1) Mechanical Alternator

(2) CHECK VALVES

(1) Thermometer

(1) Vacuum Relief Valve

(1) Compound Gauge

(1) Gauge Glass Assembly

(1) NEMA 1 700 SERIES CONTROL COMPLETE WITH THE FOLLOWING:

(1) 24" x 24" Enclosure

(1) Disconnect Switch

(4) Fuse Blocks With Fuses

(8) "0" Magnetic Starters

(4) H.O.A. Selector Switches

(1) 208/110V Control Transf

(1) Terminal Strip

(1) Ground Lug

C. Delivery of Supplies

1. Construction related deliveries which are directly shipped to the institution can be received between the hours

of 8:O0 AM - 2:30 PM, Monday - Friday, excluding federal holidays

Files

File Type Posted
24Z5AR9 - REPLACE VACUM CONDENSATE SYSTEM RFQ.pdf PDF
Scope of Work.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z2FF-FCI El Reno-Replacement of Housing Unit HVAC Systems El Reno, Oklahoma 73036, United States · NAICS 238220 BOP Field Acquisition Office No set-aside
J043--Damen Building Vacuum Condensate System Rebuild Jesse Brown VA Medical Center 820 S. Damen Ave, Chicago, IL 60612 · NAICS 238220 Veterans Integrated Service Network 12 No set-aside
FPC bryan, TX - replace HVAC system ICC building Texas 77803, United States · NAICS 333415 Federal Correctional Institution Beckley Total Small Business
Replace Water Tanks FCI Marion Marions, Illinois Illinois 62959, United States · NAICS 238220 BOP Field Acquisition Office Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors