Replace Seals, Building 4305 FRCE
Cancelled Solicitation Posted
- Solicitation number
- N400857516334
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- 8(a) Sole Source
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Cherry Point, North Carolina 28533, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Naval Facilities Engineering Command seeks replacement of seals on three pipe penetrations in Building 4035 at Marine Corps Air Station Cherry Point, North Carolina, with proposals due September 3. This procurement is an 8(a) sole source set-aside exclusively for N4008524D0066 Driven Contractors, LLC.
Place of performance is MCAS Cherry Point, NC. The work involves removing deteriorated sealing elements installed circa 2012 from a cyanide secondary containment system's mechanical room and installing new modular pipe sealing systems featuring nitrile green rubber seal elements, reinforced nylon polymer pressure plates, and 316 stainless steel hardware, similar to Link-Seal Model OS-316, per manufacturer specifications. Contractor personnel must obtain Defense Biometrics Identification System credentials or One-Day Passes and FRC East security badges prior to work commencement.
Work involves hazardous conditions requiring compliance with FRC East Instruction 5100.14C (Confined Space Entry program) and FRC East Instruction 5100.2 (occupational safety and health). Contractor must provide appropriate personal protective equipment and obtain a Confined Space Entry permit; FRC East's HAZMAT team handles sump emptying. A single superintendent must fulfill roles of Superintendent, Quality Control Manager, and Site Safety and Health Officer. Work occurs during standard hours 0700 to 1600 Monday through Friday, excluding federal holidays. Contractor must verify existing pipe and seal sizes, test new seals for leaks upon completion, and return the area to original condition. Planned utility outages require fourteen days' prior written notification with contingency plans to the Contracting Officer. Closeout submittals include spare parts data, warranty management plan, and operation and maintenance manuals. NAICS code 238220 applies; PSC code is Z2JZ.
Notice text
This contract opprutunity is set-aside for N4008524D0066 Driven Contractors, LLC. to meet NAVFAC's business standards of providing opprutunites to local disadvantaged and small 8(a) businesses.
Files
| File | Type | Posted |
|---|---|---|
| 7516334 DWG.pdf | ||
| 7516334 MACC.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Sealer, surface | Naval Supply Systems Command | No set-aside | |
| Sealing compound | Construction and Equipment | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity