Replace Air Conditioning Unit 3 at Building 23

Closed Pre-Solicitation Posted

Solicitation number
Presolicitation_Notice_B23_ACU-3_Replacement
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Van Nuys, California 91406, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army National Guard is seeking to replace air conditioning unit 3 (ACU-3) at Building 23 of the Sepulveda Air National Guard Station in California. The current 20-year-old unit has a failed condenser, requiring replacement by trained HVAC experts. The replacement unit must be a 10-ton heat pump compatible with the existing BACnet Communications Interface, installed per the manufacturer's specifications in the same location using the existing power and control wiring. Following replacement, a startup and operational test must be performed to ensure the heat pump is functioning properly.

This pre-solicitation notice has been set aside for service-disabled veteran-owned small businesses (SDVOSB). The contracting office is the 195th Wing/Mission Support Contracting (195 WG/MSC) at Beale Air Force Base, California. The NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, and the PSC code is N045-P - Installation Of Equipment- Plumbing, Heating, And Waste Disposal Equipment. The response is due by June 26, 2024.

Notice text

ACU-3 is responsible for a portion of Building 23 HVAC requirements for the 261st Cyber Operations Squadron at Sepulveda ANGS, California. Manufactured in June 2004, the unit is 20 years old. The condenser has failed, and there could be additional issues. This air conditioning unit must be replaced by trained HVAC experts equipped with the necessary tools for the job.

The current ACU is a Trane Precedent, with model number YHC120A4RMA1KD1C3A2B0A606 and serial number 426100285L. For this replacement, specialized testing equipment is required to calibrate and tune certain inputs and outputs for maximum system efficiency. The replacement unit must be a 10-ton heat pump compatible with the existing BACnet Communications Interface. The installation process must adhere to the manufacturer's specifications. The new unit will be installed in the same location, using the existing power and control wiring. Following replacement, a startup and operational test must be performed to ensure the heat pump is functioning properly.

Files

File Type Posted
Synopsis_B23_ACU-3_Replacement.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Air conditioner NAICS 333912 Construction and Equipment No set-aside
4120--rental of two chillers for one year Asheville, North Carolina 28805, United States · NAICS 238220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement Jbsa Ft Sam Houston, Texas 78234, United States · NAICS 238220 Air Education and Training Command No set-aside
Parts kit, air conditio NAICS 333415 Construction and Equipment Service-Disabled Veteran-Owned Small Business
TVHS AC VRF System Installation Nashville, Tennessee 37212, United States · NAICS 238220 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity