This document is a Presolicitation Notice for the replacement of air-conditioning unit 3 (ACU-3) at Building 23 of the Sepulveda Air National Guard Station in California. The current ACU-3 unit is 20 years old with a failed condenser, requiring replacement by trained HVAC experts. The replacement unit must be a 10-ton heat pump compatible with the existing BACnet Communications Interface, installed per the manufacturer's specifications in the same location using the existing power and control wiring. Following replacement, a startup and operational test must be performed. The solicitation will be set aside for service-disabled veteran-owned small businesses (SDVOSB), with a response due date to be determined. The contracting office is the 195th Wing/Mission Support Contracting (195 WG/MSC) at Beale Air Force Base, California.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice

Date 24 June 2024 Product or service code N045, Installation of equipment—Plumbing, Heating, and Waste Disposal Equipment Contracting office address 195th Wing/Mission Support Contracting (195 WG/MSC) 17840 13th St, Building 2180, Beale AFB, California 95903 Subject Replace air-conditioning unit 3 (ACU-3) at Building 23, Sepulveda ANGS Proposed solicitation number

W50S6U24QA011

Closing response date To be determined Contact point or contracting officer Kristian Perlas, email kristian_martin.perlas.2@us.af.mil and Carmen Ridener, email carmen.ridener@us.af.mil Description ACU-3 is responsible for a portion of Building 23 HVAC requirements for the 261st Cyber Operations Squadron at Sepulveda ANGS, California. Manufactured in June 2004, the unit is 20 years old. The condenser has failed, and there could be additional issues. This air conditioning unit must be replaced by trained HVAC experts equipped with the necessary tools for the job.

The current ACU is a Trane Precedent, with model number YHC120A4RMA1KD1C3A2B0A606 and serial number 426100285L. For this replacement, specialized testing equipment is required to calibrate and tune certain inputs and outputs for maximum system efficiency. The replacement unit must be a 10-ton heat pump compatible with the existing BACnet Communications Interface. The installation process must adhere to the manufacturer's specifications. The new unit will be installed in the same location, using the existing power and control wiring. Following replacement, a startup and operational test must be performed to ensure the heat pump is functioning properly.

Place of contract performance Sepulveda Air National Guard Station 15900 Victory Blvd, Building 23, Van Nuys, CA 91406-6451 Set-aside status Competitive Service-disabled veteran-owned small business (SDVOSB)