Repair TBS Electric System - Substation
Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- ACQR5797039
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Not on record
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237130 Power and Communication Line and Related Structures Construction
- Place of performance
- Quantico VA 22134 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks proposals to repair the electrical system substation aboard Marine Corps Base Quantico in Virginia. The Naval Facilities Engineering Command will replace aging 15kV and 35kV switchgears with new pad mounted gas insulated switchgear featuring microprocessor controls. Proposals will be evaluated based on experience performing similar electrical infrastructure upgrades on military installations. The deadline for any questions is August 15th, with final proposals due by September 1st.
This is a total small business set-aside opportunity. The primary NAICS code is 238210 and PSC code is R499. As the incumbent, the contractor must have experience servicing electrical distribution equipment. The period of performance is 12 months with an expected value between $3-5 million. Exact quantities will be determined upon award but include no less than four 15kV and two 35kV switchgear enclosures.
Notice text
The general scope of this project is to provide all labor, material, equipment, transportation and supervision necessary to repair the TBS Electrical System – Substation aboard MCB Quantico, VA. The contractor shall perform all work as necessary to complete the contract in a satisfactory and acceptable manner; and adhere to all applicable federal, state and local regulations.
The main scope items for the work includes replacement of the existing TBS’s 15 kV switchgears with pad mounted gas-insulated 15 kV switchgear with microprocessor based interrupters and the existing FBI Academy’s 35 kV switchgear with pad mounted gas insulated 35 kV switchgear with microprocessor based interrupters. This project will also reconnect existing 120-volt circuits currently fed from the 35 kV switchgear enclosure.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair TBS Electric System - Substation | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Switch | Naval Supply Systems Command | No set-aside | |
| Kite terminal conso | Naval Supply Systems Command | No set-aside | |
| Switch, proximity | Naval Supply Systems Command | No set-aside | |
| Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA) | District Washington | No set-aside | |
| Circuit breaker, in repair/modification of | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity