Repair Power Lab Air Compressor

Closed Solicitation Posted

Solicitation number
70Z03926QCGA00031
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
New London, Connecticut 06320, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Homeland Security Coast Guard seeks repair of an Ingersoll Rand Model R5.5i-A125 air compressor located at McAllister Hall, United States Coast Guard Academy, with quotes due August 31, 2026. This is a 100% Small Business set-aside on a restricted basis.

Place of performance is New London, Connecticut. Work scope includes performing lockout/tagout procedures, replacing the failed cooling fan, inlet valve, unload solenoid, blowdown valve, air filter, oil filter, air/oil separator, and drive belt; removing an oil sample and changing the oil; checking the scavenge line; cleaning coolers and panel filter; greasing the motor if applicable; and testing the unit for proper operation before returning it to service. All contractor personnel must possess the necessary qualifications, experience, and certifications to perform repair and replacement work in compliance with applicable federal, state, and local requirements and industry standards; State of Connecticut licensing is not mandatory if personnel meet these alternative requirements. Work must be performed between 7:30 a.m. and 4:00 p.m., Monday through Friday, excluding Federal Holidays, unless prior approval is obtained from Technical Advisor Jason Askew (Jason.M.Askew@uscg.mil). Personnel accessing the facility must present a "real" ID (driver's license with a star).

The NAICS code is 811310, Commercial and Industrial Machinery and Equipment Repair and Maintenance, with a business size standard of $12.5 million. The contract type is Firm Fixed Price. Award will be made using Lowest Price Technically Acceptable evaluation. Questions are due August 24, 2026 at 8:00 AM Eastern Standard Time. Site visits are not required but may be arranged by contacting Jason Askew. Quotes must be submitted via email to Kayla.L.Rex@uscg.mil.

Notice text

The contractor shall provide all labor, materials, equipment, transportation, and supervision necessary to repair the Ingersoll Rand Model R5.5i-A125 air compressor located in McAllister Hall at the United States Coast Guard Academy, New London, Connecticut. Work includes performing lockout/tagout procedures, replacing the failed cooling fan, inlet valve, unload solenoid, blowdown valve, air filter, oil filter, air/oil separator, and drive belt; removing an oil sample and changing the oil; checking the scavenge line; cleaning coolers and panel filter; greasing the motor if applicable; and testing the unit for proper operation before returning it to service.

Files

File Type Posted
AIR COMPRESSOR QandA.docx DOCX document
SOW - Repair air compressor.docx DOCX document
Combined Synopsis Solicitation_AIR COMPRESSOR.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Compressor, rotary NAICS 333914 Naval Supply Systems Command No set-aside
Compressor unit, REF, in repair/modification of NAICS 333415 Naval Supply Systems Command No set-aside
USCGC Healy Compressor lobes Seattle, Washington 98134, United States · NAICS 336611 — Total Small Business
Repair kit, compressor NAICS 333912 Land and Maritime No set-aside
Full & Open Brand Name OEM "Curtiss-Wright Electro-Mechanical Corp" - Low Pressure Air Compressor (LPAC) Maintenance Services Japan · NAICS 336611 Naval Supply Systems Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity