Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston, South Carolina
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- FA441820R0014
- Agency
-
Air Mobility Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- Charleston Afb Sc 29404 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks capabilities statements for the repair of HVAC systems at dormitory buildings 2405 and 2406 at Joint Base Charleston, South Carolina. The Department of the Air Force Air Mobility Command requires exterior wall and roof repairs, removal and replacement of mechanical equipment and ductwork, replacement of fire dampers, and structural column repairs. Interested parties must have small business status and relevant experience. Responses are due by July 9, 2020 and the solicitation is expected to be posted on August 10, 2020. The work is to be completed within 715 calendar days and will be evaluated under NAICS code 236220.
The opportunity is set aside for total small businesses. The estimated value is between $1 million and $5 million to be performed under NAICS code 236220 over 715 calendar days. The repair work includes exterior sealant replacement, mechanical equipment replacement, and structural repairs. The pre-solicitation notice provides potential contractors advance notice to assess their ability to perform the stated work.
Notice text
The 628th Contracting Squadron at Joint Base Charleston, SC is seeking capabilities packages from potential sources for planning purposes for the Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston, South Carolina.
The work includes exterior wall repairs and modifications, complete removal and replacement of all exterior sealant joints including all liquid applied sealants, backer rods and silicone tape system on exterior walls at building expansion joints. Metal roof repairs and modifications.
Roof gable louvers will be removed to provide access for removal of existing mechanical equipment and installation of new mechanical equipment. After the new mechanical equipment have been placed in the mechanical attic space a new louver with insulated closure panel will be installed. New backer rod and sealant will be installed around the perimeter of new louvers to provide a sealed condition. Perform an asbestos/lead survey before working.
In the attic of each wing, replace the existing variable air volume air handling unit and dedicated outdoor air handling unit with a single new variable air volume air handling unit and an inline supply fan. Replace the existing energy recovery module (ERM), exhaust fan (EF), and filter modules. Replace a portion of the chilled water piping and ductwork such that the new equipment can be installed. Test the existing fire dampers and replace any fire dampers that are found to be faulty.
Existing hip and ridge beams are to be supported by temporary screw jack shoring. Existing HSS columns and anchor bolts to be removed. Existing base plate of columns to be removed, and new base plate w/ alternate bolt pattern to be installed on existing columns. After equipment is removed and replaced, columns shall be reinstalled w/ epoxy anchors into existing concrete. The anticipated performance time is 715 calendar days. The breakdown of this time is 45 days for submittals, 90 days for long lead time equipment, and 550 days for construction to include weather days and 30 days for closeout documentation.
Files
| File | Type | Posted |
|---|---|---|
| DKGV 1073189 Sources Sought Repair HVAC Dormitory B2405 B2406 20200623.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston -Weapons Station, Goose Creek, South Carolina | Award Notice | |
| Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston -Weapons Station, Goose Creek, South Carolina | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business | |
| FY27 HVAC Maintenance Service | MICC Fort Sam Houston | Total Small Business | |
| J041--White City B249 SE HVAC Repair | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| FA8501-27-RAPID-990029 RPR RPL HVAC SYSTEM BLDG 300 Bay A/Headhouse | Air Force Sustainment Center | No set-aside | |
| Repair Mechanical Systems IDIQ (FY 27-32) | AFLCMC Wright Patterson AFB | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity