About this opportunity
This pre-solicitation notice seeks architectural and engineering design services for the repair of the fire detection system and finishes at Building 1146 on Eielson Air Force Base in Alaska. The Department of the Air Force Pacific Air Forces requires interested firms to review the attached statement of work and facility drawings and respond via email by the specified deadline to express their capability and interest. The selected firm must have experience designing fire detection systems in compliance with UFC 3-600-1, NFPA 72, NFPA 101, and IFS standards, as well as assessing building envelopes, designing three-hour rated barriers, conducting hazardous materials surveys, and addressing Arctic conditions.
The opportunity is set aside for total small business concerns. Relevant NAICS codes include 541310 and PSC code R425. The budget for the project is $500,000. Interested firms must complete 95% of the design work within 21 days of notice to proceed and achieve 100% completion within 14 days thereafter. A one-year warranty on materials and workmanship will commence upon final acceptance of the completed repair work.
Notice text
This notice is a Sources Sought. The Sources Sought notice is a synopsis posted by a Government agency seeking possible sources for a project. This notice is not a solicitation for work or a request for proposal.
The purpose of this notice is to identify interested and capable vendors to perform thework described below and to incorporate the results of this notice into the Government's Market Research Report. Please review the Government's draft Statement of Work.
Respond to this notice by emailing SSgt Elias A. Campos at elias.campos.1@us.af.mil and Mr. Darnell M. Holliman stating your firm's interest in accomplishing this effort.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| AE: FTQW 25-1101 Repair Fire Detection System | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade | Veterans Integrated Service Network 2 | No set-aside | |
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business | |
| Fire apparatus intercom system uplift and installation | Air Force Test Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity