Repair Elevator - Bldg 425 Dayton VAMC (Services)
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25026Q0673
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238290 Other Building Equipment Contractors
- Place of performance
- Dayton, Ohio 45428, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 seeks repair of one elevator in Building 425 (Fisher House) at the Dayton VAMC, with proposals due July 21, 2026 at 3:00 PM Eastern Time. This procurement is a 100% service-disabled veteran-owned small business (SDVOSB) set-aside, restricting competition to that category.
Place of performance is Dayton, Ohio (4100 W. 3rd Street, Dayton, Ohio 45409). The elevator, a ThyssenKrupp TKE Tac 32 passenger elevator with 3,000-pound capacity and 100 feet per minute rated speed, is out of service due to electrical storm damage. Work involves removing and repairing the I/O board, installing a new CPU board, reprogramming the elevator, and performing comprehensive safety checks including fire recall procedures. All work must be performed by certified elevator technicians in compliance with ASME A17.1 safety standards and OSHA regulations, and must be completed within 90 days of award during normal business hours (Monday–Friday, 0800–1630 ET) excluding federal holidays. Contractor personnel requiring unescorted facility access or logical access to VA information systems must comply with personnel vetting, credentialing, and Personal Identity Verification requirements under VAAR 852.204-72 and VAAR 852.204-70 (both June 2026 versions). An organized site visit was held July 15, 2026 at 11:00 AM ET. The contract ceiling is $22 million. Evaluation is based on price alone, and this is a firm-fixed-price acquisition. Offerors must certify compliance with VAAR 852.219-75 subcontracting limitations (prime contractor may not pay more than 50% of government payment to non-certified SDVOSB/VOSB firms). NAICS code is 238290; PSC code is Z1AZ. Contracting Officer: Brian Rosciszewski (Brian.Rosciszewski@VA.gov).
Notice text
3 versions
Update #3 · Latest ·
Bldg. 425, also known as the Fisher House, is a two-story building. It has one elevator that is currently out of service due to damage from an electrical storm. The facility has determined that the elevator’s I/O board requires repair and its central processing unit (CPU) must be replaced.
A site visit is schedule on July 15, 2026, subject to amendment. See Section D of the solicitation for details.
Amendment 0001 - Change to two VAAR clauses.
Amendment 0002 - Site Visit log and VAAR 852.219-75.
Update #2 ·
Bldg. 425, also known as the Fisher House, is a two-story building. It has one elevator that is currently out of service due to damage from an electrical storm. The facility has determined that the elevator’s I/O board requires repair and its central processing unit (CPU) must be replaced.
A site visit is schedule on July 15, 2026, subject to amendment. See Section D of the solicitation for details.
Modification 0001
Change to two VAAR clauses.
Update #1 ·
Bldg. 425, also known as the Fisher House, is a two-story building. It has one elevator that is currently out of service due to damage from an electrical storm. The facility has determined that the elevator’s I/O board requires repair and its central processing unit (CPU) must be replaced.
A site visit is schedule on July 15, 2026, subject to amendment. See Section D of the solicitation for details.
Files
| File | Type | Posted |
|---|---|---|
| 36C25026Q0673 0002.pdf | ||
| Attach II - VAAR 852.219-75 VA NOTICE OF LIMITS ON SUBCONTRACTING_CERT OF COMPLIANCE FOR SERVICES AND CONSTRUCTION JAN 2023 DEV.docx | DOCX document | |
| Attach I - Site Visit - Elevator Repair.docx | DOCX document | |
| 36C25026Q0673 0001.pdf | ||
| 36C25026Q0673 synopsis.pdf | ||
| 36C25026Q0673 solicitation.pdf | ||
| SCA - Mntgmy Cty 15-4731 - 5.13.26.txt | TXT text file |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1AZ--Elevator Repair Bldg 425 -Services | Award Notice | |
| This notice | Solicitation | |
| Z1AZ--Elevator Repair at Dayton VAMC | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C1DA--AE Replace Elevators Cx 539-24-102 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA-- AE Replace Elevators 539-24-102 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| J039--561A4-25-500 Elevator Upgrade & Modernization Repairs at VA NJ HCS Lyons Buildings 6 & 53 | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Project No. 539-24-101 - Replace Failing Electrical Equipment. | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business |