Repair Data Lab & FTI Building 423
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- FA4861-10-R-A029
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- HUBZone
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
3 versions
Update #3 · Latest ·
Q1) Will the 100% design drawings from HDR Engineering, Inc. be provided to the winning bidder in AutoCAD format?
A1. AutoCAD drawings will be provided to successful bidder.
Q2) If so, will the drawings be unlocked (not read-only) so that they may be used to create the As-Builts?
A2. Drawings will be unlocked and can be used for as-builts.
Q3) The cover sheet states that the drawing set is "For Construction". However, the Fire Protection sheets of the drawing set, FP100 through FP109, contain the disclaimer that "These concept drawings are for information only to show potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for the design and installation of the system IAW the specifications." 1) Should bidders include costs to design the fire protection system? 2) Will a "Design" performance period be added in addition to the 220 CD for construction?
A3. Project fire protection drawings and specifications are procurement documents. Contractor shall provide professionally stamped fire protection system shop drawings/system design per requirements stated in project drawings, specifications, and UFC 3-600-01. Shop drawings shall be submitted per contractor’s approved submittal schedule.
Q4) Reference: Attachment #3; Technical Specification; Section 08 71 00; paragraph 3.6; Hardware Sets. The door hardware schedule for 14 doors is prefaced with the statement: "(Coordinate hardware with Base Access Control System - Door to be card reader operated and alarmed with BMS - security hardware to be installed by others.)" Questions: 1) What is the "Base Access Control System"? Is it user supplied or Contractor supplied? 2) What "security hardware" will be installed by others?
A4. Access Control System for facility (main panel, electronic card readers, key pads) will be Government furnished and installed. Specified door hardware, balanced magnetic switches, and conduit/junctions boxes for ACS are Contractor furnished and installed.
Q5) Telecommunication Plan sheets ET102 and ET105 reference CAT 6 cable. Telecommunication Plan sheets ET102 and ET104 reference CAT 6E cable. Question: Which type of cable is to be used for this project; CAT 6 or CAT 6E.
A5. Provide CAT 6 cable per project specifications.
Update #2 ·
**********SOLICITATION NUMBER IS FA4861-10-B-A029********** Project work shall consist of furnishing all labor, supplies, materials, supervision, transportation equipment, demoltion, and all other work required to renovate/repair Building 423 at Nellis Air Force Base, NV. Project scope includes the repair and reconfiguration of existing facility to function as an aircraft Data Lab and Flight Test Lab with offices, multi-use rooms, a secured storage vault, and a security office. The FTI workshop includes an open shop area for maintenance and storage of instrument pods, a parts/tool room, an instrument pod test room, a classified pod maintenance room, offices, and secured storage room. A portion of the facility will be renovated to house administration functions for 53 EWG. Large portions of facility will be built to meeti JAFAN 6/9 CONUS requirements for Special Access Program Facilities. Existing Building 423 area is approximately 19,500 SF and facility is a single story load-bearing masonry structure atop a reinforced concrete slab on grade. Substantial HVAC, plumbing, electrical, fire exterior work is required. Complete project construction documents will be provided to bidders. The Period of Performance for this project is 300 Calendar days from receipt of the Notice to Proceed.
*** Funds are not presently available for this project. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date. ***
Magnitude: The North American Industry Classification System (NAICS) code is 236220 with a size standard of $33.5 million. The project magnitude is between $1,000,000 and $5,000,000.
It is anticipated the solicitation will be issued electronically on or about 13August 2010, on the Federal Business Opportunities (FBO) web page. Paper copies will not be available. Once the solicitation is posted, it is incumbent upon the interested parties to review this site frequently for any updates/amendments to any and all documents.
Note: Any prospective contractor must be registered in the Central Contractor Registration (CCR) database in order to be eligible for award. Registration requires applicants to have a DUNS number from Dun and Bradstreet. Registration may take up to three weeks to process. Recommend registering immediately in order to be eligible for timely award. Effective 01 Jan, 2005, the Federal Acquisition Regulation (FAR) requires the use of Online Representations and Certifications Application (ORCA) in Federal solicitations as part of the proposal submission process. All prospective contractors submitting an offer in response to the subject solicitation must go to http://www.bpn.gov/ to add or update its ORCA record. Primary POC is 1Lt William Barrett at (702) 652-9335; email: william.barrett@nellis.af.mil. Alternate POC is Richard Jedlinski at (702) 652-9121; email: richard.jedlinski@nellis.af.mil.
Update #1 ·
Project work shall consist of furnishing all labor, supplies, materials, supervision, transportation equipment, demoltion, and all other work required to renovate/repair Building 423 at Nellis Air Force Base, NV. Project scope includes the repair and reconfiguration of existing facility to function as an aircraft Data Lab and Flight Test Lab with offices, multi-use rooms, a secured storage vault, and a security office. The FTI workshop includes an open shop area for maintenance and storage of instrument pods, a parts/tool room, an instrument pod test room, a classified pod maintenance room, offices, and secured storage room. A portion of the facility will be renovated to house administration functions for 53 EWG. Large portions of facility will be built to meeti JAFAN 6/9 CONUS requirements for Special Access Program Facilities. Existing Building 423 area is approximately 19,500 SF and facility is a single story load-bearing masonry structure atop a reinforced concrete slab on grade. Substantial HVAC, plumbing, electrical, fire exterior work is required. Complete project construction documents will be provided to bidders. The Period of Performance for this project is 300 Calendar days from receipt of the Notice to Proceed.
*** Funds are not presently available for this project. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date. ***
Magnitude: The North American Industry Classification System (NAICS) code is 236220 with a size standard of $33.5 million. The project magnitude is between $1,000,000 and $5,000,000.
It is anticipated the solicitation will be issued electronically on or about 11 August 2010, on the Federal Business Opportunities (FBO) web page. Paper copies will not be available. Once the solicitation is posted, it is incumbent upon the interested parties to review this site frequently for any updates/amendments to any and all documents.
Note: Any prospective contractor must be registered in the Central Contractor Registration (CCR) database in order to be eligible for award. Registration requires applicants to have a DUNS number from Dun and Bradstreet. Registration may take up to three weeks to process. Recommend registering immediately in order to be eligible for timely award. Effective 01 Jan, 2005, the Federal Acquisition Regulation (FAR) requires the use of Online Representations and Certifications Application (ORCA) in Federal solicitations as part of the proposal submission process. All prospective contractors submitting an offer in response to the subject solicitation must go to http://www.bpn.gov/ to add or update its ORCA record. Primary POC is 1Lt William Barrett at (702) 652-9335; email: william.barrett@nellis.af.mil. Alternate POC is Richard Jedlinski at (702) 652-9121; email: richard.jedlinski@nellis.af.mil.
Files
Show all 16
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair Data Lab & FTI Building 423 | Solicitation | |
| This notice | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity