Repair Bldg 75 HAZMAT Storage HVAC

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
PANNGB-21-P-0000-003293
Agency
Vermont National Guard Army National Guard, Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z2GZ Repair Or Alteration Of Other Warehouse Buildings
Place of performance
South Burlington, Vermont 05403, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Vermont Army National Guard intends to issue a solicitation to repair the HVAC systems at Building 75, which is used for hazardous material storage, at the Vermont Air National Guard Base. Work includes demolishing existing HVAC equipment and ductwork and installing new HVAC systems, including a mixed air unit, fan coils, unit heaters and controls connecting to the base's Direct Digital Control network. Interested contractors must complete and return the attached response form by February 28th, providing company and bonding information and certifications.

There is no set-aside for this opportunity, which has an estimated value between $250,000-500,000. The repair work involves modifying an existing 1,800 square foot facility and replacing the HVAC systems that support the storage of hazardous materials. If sufficient small business contractors are identified as capable of performing the work, the opportunity will be set aside for small businesses. Otherwise, it will be open to all interested parties.

Notice text

The purpose of this Sources Sought is to gain knowledge of potential sources for this project including interested Small Business sources.  This notice is for planning purposes only.  All interested parties should respond.  The Vermont Air National Guard Base, Vermont intends to issue a solicitation and award of a contract to Repair Bldg 75 HAZMAT Storage HVAC.

Work includes modifying existing 1,800sf facility utilizing conventional construction methods to accommodate the mission of the facility.  Facility will receive all required HVAC modifications to allow safe storage of HAZMAT to include heating, ventilation, air conditioning, ventilation and related controls.  Demolish, remove and dispose of existing HVAC systems (including mixed air unit, fan coils, unit heaters) and associated ductwork/piping and electrical work as noted in project drawings and specifications.  Install new HVAC systems, to include required electrical connections to existing panels and new controls connecting to existing base’s Direct Digital Control (DDC) network as noted in project drawings and specifications

The magnitude of this project is between $250,000 and $500,000.  All interested concern should complete the attached Sources Sought Response Form and return by email to the Primary Point of Contact for this notice.  PLEASE INCLUDE – Sources Sought - B75 HAZMAT Storage HVAC in the Subject Line of the email.

In the event adequate Small Business contractors are not available for adequate competition for this project, it may advertised as unrestricted.

Attachments

Files attached to this notice, newest first
File Type Posted
Sources Sought Response VTANG Repair B75 HAZMAT Storage HVAC.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Repair HVAC B75 HAZMAT Storage Award Award Notice
Repair HVAC B75 HAZMAT Storage Latest solicitation Solicitation
Repair HVAC B75 HAZMAT Storage Pre-Solicitation
Repair Bldg 75 HAZMAT Storage HVAC This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity