Reagents for sequencing in MiSeq and MiniSeq platforms

Closed Special Notice Posted

Solicitation number
VEID260013
Agency
Responses due
Set-aside
8(a) Sole Source

Opportunity facts

Place of performance
Callao Callao Peru

Notice details come from SAM.gov. Updated .

About this opportunity

Naval Supply Systems Command issued a sole-source 8(a) Special Notice on July 14, 2026, for reagents supporting next-generation sequencing operations at the U.S. Naval Medical Research Unit SOUTH (NAMRU SOUTH) in Callao, Peru, with responses due by July 29, 2026.

NAMRU SOUTH's Virology Department requires library preparation and sequencing reagents compatible with Illumina MiSeq and MiniSeq platforms. The library preparation kit must perform enzymatic fragmentation, size selection, end-repair, a-tailing, and ligation in a single reaction, support dual indexing at the 5' and 3' ends, and accommodate low DNA input of approximately 50 nanograms with master-mixed ready-to-use reagents. The sequencing kit must support more than 150 sequencing cycles for paired-end libraries, deliver greater than 2.0 gigabases per run with high Q30 values, and include an internal control for run validation.

The specified product list includes the PhiX control v3 kit, MiSeq Reagent Kit v3 (600-cycle), Nextera XT DNA Sample Preparation Kit, Nextera XT Index Kit v2 Set A and Set B, and MiniSeq High Output Reagent Kit (300-cycles). Materials ship upon award signature. The reagents are time-sensitive with limited expiration dates and are not classified as hazardous materials. NAICS 424210 (Drugs and Druggists' Sundries Merchant Wholesalers); PSC 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets).

Notice text

PERFORMANCE WORK STATEMENT

  1. SCOPE

The laboratory of the Virology Department of the U.S. Naval Medical Research Unit SOUTH (NAMRU SOUTH) is looking to purchase reagents to prepare libraries using human samples that later will be sequenced in the MiSeq and MiniSeq platforms developed by Illumina, as part of the projects of next-generation sequencing (NGS) that are being conducted at this command.

    1. BACKGROUND

The kits must be designed for library preparation and sequencing. The library preparation kit should include a variety of steps that include enzymatic fragmentation, size selection, end-repair, a-tail and ligation step in the same reaction. The process should allow including dual index at the 5 and 3 prime ends for later sample identification. Also, the library preparation kit should be designed to construct libraries with a low DNA input (~50ng) with master-mixed reagents ready to use. Similarly, the sequencing kit should allow us to run more than 150 sequencing cycles. Those cycles are needed to run paired-end libraries with a high-quality performance. We expect to have more than 2.0Gb per sequencing run with high Q30 values. Finally, the sequencing kit should include an internal control to validate the sequencing run.

  1. REQUIREMENTS

    1. Location of work / Place of delivery

Shipment to NAMRU SOUTH – Callao, Peru

    1. Period of performance / Delivery time

In accordance with deliverables schedule.

    1. Deliverables schedule (if applicable)

Materials should be shipped upon award signature.

    1. Hazardous material category. 

None of the items are hazardous materials.

List of products

FC-110-3001  PhiX control v3 kit

MS-102-3003  MiSeq Reagent Kit v3 (600-cycle)

FC-131-1096  Nextera XT DNA Sample Preparation Kit

FC-131-2001 Nextera XT Index Kit v2 Set A (96 indexes, 384 samples)

FC-420-1003  MiniSeq High Output Reagent Kit (300-cycles)

FC-131-2002  Nextera XT Index Kit v2 Set B (96 indexes, 384 samples)

Applicable Standards

These reagents are very time-sensitive and have limited expiration dates, reason for which, vendor should inform final users of expiration dates as soon as they become available and request their approval prior to shipment.

Special Requirements

All materials require cold chain.

Similar open opportunities

Opportunity Agency Set-aside Responses due
NOI - DNA Sequencing of Bone Marrow Failure Syndro NAICS 325413 Office of Logisitics and Acquisition Operations No set-aside
Comprehensive full-service maintenance/repair plan for Illumina Nova/Seq 6000 Silver Spring, Maryland 20910, United States · NAICS 811210 Naval Supply Systems Command No set-aside
Comprehensive full-service maintenance/repair plan for Illumina Nova/Seq 6000 Frederick, Maryland 21702, United States · NAICS 334516 Naval Supply Systems Command No set-aside
Reagents and consumables for Roche immunostainers Bethesda, Maryland 20892, United States · NAICS 325413 Office of Logisitics and Acquisition Operations No set-aside