About this opportunity
This solicitation is for the procurement of a XYZ (three axis) manipulator to position an x-ray detector in a vacuum chamber, on behalf of the Department of Energy Office of Science. The key requirements include an X and Y travel of 25 mm with 5 micron or better resolution, a Z travel of 400 mm with 5 micron or better resolution, a clear aperture to allow for passage of a 38 mm diameter sensor head, stepper motor driven axes with absolute encoding, and profile rail type guides. The fixed flange is 6" OD CF and the moving flange is 4.5" OD CF, with a moving flange load capacity of 137 N vertically and 14 N*m horizontally. Responses to this Request for Quotation (RFQ) are due by April 19, 2024.
This solicitation does not have a set-aside designation. The applicable NAICS code is likely 333249 (Other Industrial Machinery Manufacturing) and the PSC code is likely 4235 (X-Ray Equipment). The place of performance is Lemont, IL 60439, USA. No incumbent contractors were named, and the total award value was not specified. The solicitation was issued under Contract No. DE-AC02-06CH11357.
Notice text
This solicitation is for a XYZ (three axis) manipulator to position a x-ray detector in a vacuum chamber (1E-7 mbar). The device will bolt to a fixed flange on the side of the vacuum chamber and the moving flange to an x-ray detector. The following specifications are to be met:
- X and Y travel of 25 mm with 5 micron or better resolution
- Z travel of 400 mm with 5 micron or better resolution
- Clear aperture shall allow for passage of a 38 mm diameter sensor head
- The fixed flange is a 6” OD CF and the moving flange is 4.5” OD CF
- All axes are stepper motor driven
- All axes must have absolute encoding
- All axes must be guided by profile rail type guides, no ball bushings are allowed
- The moving flange load capacity should be 137 N in the vertical and 14 N*m about the horizontal axis
Files
| File | Type | Posted |
|---|---|---|
| 4-B138-Q-00398-00 RFQ.doc | DOC document | |
| Reps and Certs ANL-70A.doc | DOC document | |
| Special Cl-Progress Pmts-02-SEP-2015.pdf | ||
| Special Cl-Inconsistency-01-FEB-2000.pdf | ||
| Appendix A-71COM-13-FEB-2023.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Micro Electron Diffractometer (MicroED) System | Department of Energy | No set-aside | |
| CPMU - HRD Insertion Device | Office of Science | No set-aside | |
| PIP-II ssrs and LB650 vacuum gauge and readout | Fermi National Accelerator Laboratory | No set-aside | |
| LT-SPM | Office of Science | No set-aside | |
| GEMINI. HP. L. ASY: interferometer, Gemini-Felix, and PDM module | Department of Energy | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity