Preventative maintenance service for Tunnel/Rack/ultrasound washer and Sterilizer
Closed Solicitation Posted
- Solicitation number
- HT940625QE006
- Agency
-
Defense Health Agency
Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Portsmouth, Virginia 23708, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Defense Health Agency is seeking a contractor to provide preventive maintenance services for medical equipment at Naval Medical Center Portsmouth, specifically for one Lynx Tunnel Washer, one Schlyer Rack Washer, and one Crest Ultrasonic Washer located in Building 274. This non-personal services contract requires the contractor to perform annual preventive maintenance visits, including inspection, adjustments, and replacement of worn or defective parts to ensure proper equipment operation and calibration. The contractor must be authorized by the Original Equipment Manufacturer and maintain current qualifications throughout the contract period, providing all necessary personnel, equipment, supplies, and materials to restore equipment to normal operating condition. The evaluation will use a best value approach, with technical capabilities being the most important factor, followed by past performance and price as equal but secondary considerations. Proposals are due by September 15, 2025, following an amendment that extended the original deadline from August 29, 2025.
This procurement is set aside specifically for Women-Owned Small Business (WOSB) enterprises, with the current contract being a renewal of the previous agreement N0018322P0559. The base contract period runs from September 29, 2025, through September 28, 2026, with four additional one-year option periods available for extension. The maintenance services will be performed at Naval Medical Center Portsmouth, located at 620 John Paul Circle, Portsmouth, Virginia, specifically in Building 274's Clinical Investigation Department. The contractor will be required to provide one annual preventive maintenance service visit per year for each piece of equipment, with work scheduled Monday through Friday from 8:00 a.m. to 4:00 p.m., excluding federal holidays. All services must be completed according to manufacturer specifications, with detailed reporting required after each maintenance visit to document all work performed and parts replaced.
Notice text
1.0 GENERAL INFORMATION
1.1 This is a non-personal services contract to provide maintenance of the Tunnel Washer, Rack Washer, and two Sterilizer units in Building 274, Naval Medical Center Portsmouth.
1.1.1 Description of services/introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform maintenance of the Tunnel Washer, Rack Washer, and two Sterilizer units as defined in this Performance Work Statement (PWS).
1.1.2 Background: This is a renewal of previous non-personal services contract (N0018322P0559). Annual maintenance is required to ensure proper function and calibration of the Tunnel Washer, Rack Washer, and two Sterilizer units in Building 274, Naval Medical Center Portsmouth.
1.1.3 Scope: Contractor to provide preventive maintenance and repair service on equipment identified below. Services include inspection, corrections, adjustment, and replacement of worn/defective parts as required for proper equipment operation. Contractor will provide one (1) annual Preventive Maintenance Service visit per year. The contractor shall perform all services as required to restore equipment to normal operating condition.
1.1.4 Period of Performance (PoP): 29 Sep 2025 – 28 Sep 2026; with option of four additional years
1.2 Administrative specifications
1.2.1 Place of performance: The work shall be performed at Naval Medical Center Portsmouth, 620 John Paul Cir, Portsmouth, VA 23708-2297; Bldg 274 (Clinical Investigation Department), Rm 37/35B.
1.2.2 Contractors are not required to provide services on Federal holidays. Recognized Federal holidays:
New Year’s Day Labor Day
Martin Luther King Jr.’s Birthday Columbus Day
President’s Day Veteran’s Day
Memorial Day Thanksgiving Day
Juneteenth Day Christmas Day
Independence Day
1.2.3 Hours of operation: The contractor is responsible for conducting business Monday thru Friday (8:00 a.m. to 4:00 p.m.) except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings. The contractor must at all times maintain an adequate workforce for the uninterrupted performance of all tasks defined within this PWS when the Government facility is not closed for the above reasons.
1.3 Contractor Identification
1.3.1 Contractor personnel performing services in a contractor capacity in a Government facility are required to possess and wear an identification badge that displays his or her name and the name of their company. Ensure all those with whom the person interacts in any face-to-face dealings while supporting the Governemnt understands that the person is contractor support personnel.
2.0 SPECIFIC TASKS
2.1 Preventive Maintenance
2.1.1. Coordination of services: Contractor should contact the Clinical Investigation Department (CID) Representative listed in order to coordinate scheduling of visits, and upon arrival.
2.1.2. Frequency: Contractor is required to provide preventive maintenance services once per year, at a time mutually agreed upon between the Contractor and the CID Representative.
2.1.3. Services provided: Preventive maintenance services provided will include inspection, adjustments, and replacement of worn/defective parts due to normal use and conditions. Contractor’s price must be inclusive of all costs including labor and travel as required to restore equipment to normal operating condition. Contractor shall maintain equipment per Original Equipment Manufacturer (OEM) guidelines including all OEM recommended preventative maintenance visits. Contractor is not responsible for procurement of replacement parts, or labor/materials for service line fittings, utility lines, or other equipment not supplied by the OEM.
2.1.4. Equipment included: The following equipment will be serviced by the Contractor.
Quantity, Product Category, Equipment Description
1. Lynx Tunnel Washer
Model 536LX
Prop #18361169
2. Schlyer Rack Washer
Model RW6290
S/N: 101142
3. Crest Ultrasonic Washer
Model-HAL-20WRD
SN-1706H0138
2.1.5. Warranty: Contractor to warranty all completed repairs have been completed per OEM guidelines and accepted industry standards.
2.1.6. Report: The Contractor will generate a Preventive Maintenance report after each visit, containing a summary of services provided. The CID Representive will review and approve the final report. The service report shall include, but not be limited to: contract number, equipment description (model, serial number, equipment control number) contractor’s log number, detailed description of the service(s) performed, replacement part(s) information (part number, value, nomenclature, unit price, manufacturer, if not OEM, and whether the part is new/used/reconditioned), the completion date and time, man-hours expended and the hourly rate normally charged for the type of service performed, model and serial numbers, and the name of the FSE performing the service. In the event that agents / sub-contractor’s are used in the performance of repairs, said agent shall be identified on the service report by company name and contact information (i.e., telephone number).
2.2. Replacement Parts
2.2.1. New: Uses of new replacement parts only are authorized.
2.2.2. Refurbished: Refurbished or used replacement parts are not allowed unless certified by the OEM, new parts are not available, and they are specifically approved by the Government. If refurbished parts are the only viable solution, then the vendor is to receive permission (in writing) from the CID POC prior to use.
2.3. Software Updates
2.3.1. Software: Contractor shall provide any and all software updates as they become available throughout the period of performance but no later than 30 days following its release at no additional charge.
2.4. Technical Support
2.4.1. Contractor shall provide telephone support to include services for both general system operation questions and questions concerning system failures and/or faults. Calls received during normal business hours shall be responded to immediately but no later than the next business day after receipt of the call.
3.0 Qualifications/Considerations
3.1 Special Qualifications/Considerations: The contractor shall be qualified / authorized by the Original Equipment Manufacturer (OEM) in the repair of all equipment listed within this contract, such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. Contractor shall maintain current (within 2 years) qualifications throughout entire contract period. Qualification includes but not limited to the certification of all repair persons and repair facilities by the OEM as being trained / qualified to perform required repairs. The Government shall maintain the right to seek proof of qualification prior to award and anytime during contract period of performance.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| RFI - Public Address Systems Service Maintenance for Naval Medical Center Portsmouth and all Outlying Branch Clinics | Defense Health Agency | No set-aside | |
| Repair and Maintenance Service for Histology and Cytology Equipment | Defense Health Agency | Total Small Business | |
| Getinge Steam Sterilizer Repair | Naval Supply Systems Command | No set-aside | |
| Service maintenance on (3) three Dornier Genesis Imaging Systems at the Naval Medical Center San Diego | Defense Health Agency | No set-aside | |
| Wound Vac Cleaning Maintenance Service | St. Louis VAMC | Veterans Integrated Service Network 15 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity