About this opportunity

Columbus Air Force Base seeks engineering, furnishing, installation, and testing of Cat-6 premise wiring infrastructure upgrades in Buildings 246 and 414, with proposals due May 29. The procurement is set aside for Total Small Business.

Place of performance is Columbus, Mississippi. Work includes approximately 24 cable/jacks (12 duplex) in Building 246 and approximately 12 cable/jacks (3 duplex, 1 quad, 2 wall drops) in Building 414, with new Cat-6 cabling not exceeding 295 feet in length. The contractor must install new Cat-6 TIA-568B 24 or 48-port patch panels into existing communication cabinets, provide cable management and support hardware, and install new Plenum-rated Cat-6 patch cords in compliance with ANSI/TIA standards, MIL-STD-188-124B, MIL-HDBK-419A, AFSSI 7702, and NSTISSAM Tempest/2-95. All materials and equipment must be new, not refurbished, and maintainable for at least five years. All passive cabling components, including jacks, faceplates, box outlets, and raceways, must be genuine Panduit products. Cat-6 cable must be TAA compliant.

The period of performance is 90 days after contract award, with work conducted at Columbus AFB during normal duty hours, though mission requirements may necessitate evening or weekend work. The contractor must provide one-year workmanship warranty and submit deliverables including as-built drawings in AutoCAD and PDF, work schedules, weekly status reports, meeting minutes, cutover and test plans, and test reports. A U.S. citizen Project Manager and on-site Site Point of Contact fluent in English are required. No security clearances are required. The NAICS code is 238210, Electrical Contractors and Other Wiring Installation Contractors; PSC is N061. Evaluation is based solely on price and technical factors; past performance will not be evaluated.

Notice text

3 versions

Update #3 · Latest ·

Columbus AFB has a requirement for the Contractor to engineer, furnish, install, and test (EFI&T) the upgrade of premise wiring infrastructure to Cat-6 for the building's 246 (B246) and 414 (B414) at Columbus AFB, MS.


B246: The Contractor shall install approximately 24 cable/jacks (12 DPLX) and coordinate with the 14th CS/SCX to verify for exact drop locations. Install 25pr./24ga. riser cable from MDF copper terminal [66 Block] to 24p PP (CAT III, 5 or 6) in LAN cabinet.
 
B414: The Contractor shall install approximately 12 cable/jacks (3 DPLX, 1 Quad, 2 wall drops) and coordinate with the 14th CS/SCX to verify the exact drop locations. Install 25pr/24ga riser cable from MDF copper terminal [66 block] to 24p PP in LAN cabinet.

Note: An updated Statement of Work is available in the Attachments.

Questions and answers are available in the Attachments.

Update #2 ·

Columbus AFB has a requirement for the Contractor to engineer, furnish, install, and test (EFI&T) the upgrade of premise wiring infrastructure to Cat-6 for the building's 246 (B246) and 414 (B414) at Columbus AFB, MS.


B246: The Contractor shall install approximately 24 cable/jacks (12 DPLX) and coordinate with the 14th CS/SCX to verify for exact drop locations. Install 25pr./24ga. riser cable from MDF copper terminal [66 Block] to 24p PP (CAT III, 5 or 6) in LAN cabinet.
 
B414: The Contractor shall install approximately 12 cable/jacks (3 DPLX, 1 Quad, 2 wall drops) and coordinate with the 14th CS/SCX to verify the exact drop locations. Install 25pr/24ga riser cable from MDF copper terminal [66 block] to 24p PP in LAN cabinet.

Note: An updated Statement of Work is available in the Attachments.

Update #1 ·

Columbus AFB has a requirement for the Contractor to engineer, furnish, install, and test (EFI&T) the upgrade of premise wiring infrastructure to Cat-6 for the building's 246 (B246) and 414 (B414) at Columbus AFB, MS.


B246: The Contractor shall install approximately 24 cable/jacks (12 DPLX) and coordinate with the 14th CS/SCX to verify for exact drop locations. Install 25pr./24ga. riser cable from MDF copper terminal [66 Block] to 24p PP (CAT III, 5 or 6) in LAN cabinet.
 
B414: The Contractor shall install approximately 12 cable/jacks (3 DPLX, 1 Quad, 2 wall drops) and coordinate with the 14th CS/SCX to verify the exact drop locations. Install 25pr/24ga riser cable from MDF copper terminal [66 block] to 24p PP in LAN cabinet.

Files

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
Premise Wiring B246 & B414 Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity